TrolMaster MBS-PRO

TrolMaster MBS-PRO 4-in-1 Sensor Instruction Manual

Model: MBS-PRO

1. Introducció

The TrolMaster MBS-PRO is a versatile 4-in-1 sensor designed for use with the Hydro-X Pro and Hydro-X Plus environmental control systems. It accurately measures temperature, humidity, CO2 levels, and light intensity, providing essential data for optimizing your growing environment. This manual provides detailed instructions for the proper installation, operation, and maintenance of your MBS-PRO sensor.

TrolMaster MBS-PRO 4-in-1 Sensor

Figure 1: TrolMaster MBS-PRO 4-in-1 Sensor

The image displays the compact design of the TrolMaster MBS-PRO 4-in-1 sensor, featuring a white, ribbed housing with a small display screen and a cable extending from the top. This sensor is designed to monitor multiple environmental parameters.

2. Informació de seguretat

Please read all safety instructions before operating the device. Failure to follow these instructions may result in damage to the product or personal injury.

  • Do not expose the sensor to extreme temperatures or direct water spray.
  • Assegureu-vos que totes les connexions estiguin segures abans d'encendre el sistema.
  • Only use the sensor with compatible TrolMaster Hydro-X Pro or Hydro-X Plus systems.
  • Do not attempt to open or modify the sensor housing. This will void the warranty.
  • Mantenir fora de l'abast dels nens i mascotes.

3. Contingut del paquet

Verifiqueu que tots els elements siguin presents al paquet:

  • 1 x TrolMaster MBS-PRO 4-in-1 Sensor
  • 1 x RJ12 Cable (for connection)
  • 1 x Manual d'usuari (aquest document)
TrolMaster MBS-PRO Sensor in Retail Packaging

Figure 2: MBS-PRO Sensor Retail Packaging

This image shows the TrolMaster MBS-PRO 4-in-1 sensor packaged in its white retail box. The box features the TrolMaster logo and product name, indicating it's an all-in-one sensor for temperature, humidity, CO2, and light, compatible with Hydro-X Pro systems.

4. Configuració

4.1 Instal·lació física

Choose a central location within your growing area that accurately represents the overall environmental conditions. Avoid placing the sensor directly in front of fans, vents, or heating/cooling elements, as this can lead to inaccurate readings. Mount the sensor securely using appropriate hardware (not included) at the recommended height for your specific plants.

4.2 Connecting to Hydro-X Pro/Plus

The MBS-PRO sensor connects to your Hydro-X Pro or Hydro-X Plus controller via an RJ12 cable. Follow these steps:

  1. Locate an available RJ12 port on your Hydro-X Pro/Plus controller or an SPH-1 splitter.
  2. Connect one end of the RJ12 cable to the port on the MBS-PRO sensor.
  3. Connect the other end of the RJ12 cable to the selected port on your Hydro-X Pro/Plus controller or SPH-1 splitter.
  4. Assegureu-vos que les connexions siguin fermes i segures.
TrolMaster MBS-PRO Connection Diagram

Figure 3: Connection Diagram for MBS-PRO Sensor

This diagram illustrates how to connect the MBS-PRO sensors to a Hydro-X Pro controller using an SPH-1 splitter. Multiple MBS-PRO sensors are shown connected to the SPH-1, which then connects to the main Hydro-X Pro unit via a single RJ12 cable.

4.3 Configuració inicial

Once connected, the Hydro-X Pro/Plus system should automatically detect the MBS-PRO sensor. Refer to your Hydro-X Pro/Plus controller's manual for specific instructions on how to:

  • Verify sensor detection.
  • Assign the sensor to specific zones or control functions.
  • Set desired environmental parameters (temperature, humidity, CO2, light intensity thresholds).

5. Operating the MBS-PRO Sensor

The MBS-PRO sensor continuously monitors the environment and transmits data to your Hydro-X Pro/Plus controller. All readings and control adjustments are managed through the main controller interface.

5.1 Comprensió de lectures

  • Temperatura: Displays the ambient air temperature in your chosen unit (e.g., °F or °C).
  • Humitat: Mostra el percentatge d'humitat relativatage in the air.
  • CO2: Indicates the carbon dioxide concentration in parts per million (PPM).
  • Intensitat de la llum: Measures the light level, often displayed in PPFD (Photosynthetic Photon Flux Density) or Lux, depending on controller settings.

5.2 Integration with Hydro-X System

The data collected by the MBS-PRO sensor enables the Hydro-X Pro/Plus system to automate various environmental controls, such as activating fans, humidifiers, dehumidifiers, CO2 generators, and lighting systems, based on your programmed settings. Regularly review your controller's dashboard to ensure optimal conditions are maintained.

Vídeo 1: Acabatview of TrolMaster Hydro-X Controllers

Aquest vídeo ofereix una visió generalview of the TrolMaster Hydro-X controller systems, demonstrating their capabilities in managing various environmental factors. It highlights how sensors like the MBS-PRO integrate to provide comprehensive control.

Video 2: TrolMaster Controllers - Control Every Variable

This video showcases the extensive control features of TrolMaster controllers, emphasizing their ability to manage every variable in a growing environment. It illustrates the system's precision and automation for optimal plant growth.

6. Manteniment

6.1 Neteja

To ensure accurate readings, keep the sensor clean. Gently wipe the exterior of the sensor with a soft, dry cloth. Do not use abrasive cleaners or allow moisture to enter the sensor openings.

6.2 Calibració

The MBS-PRO sensor is factory-calibrated. Under normal operating conditions, re-calibration is generally not required. If you suspect inaccurate readings, consult the Hydro-X Pro/Plus controller manual for any available calibration procedures or contact customer support.

6.3 Emmagatzematge

When not in use, store the sensor in a cool, dry place away from direct sunlight and extreme temperatures. Disconnect it from the controller and store the cable neatly.

7. Solució De Problemes

ProblemaCausa possibleSolució
Sensor not detected by controllerLoose RJ12 cable connection; Faulty cable; Controller port issue; Sensor malfunction.Check and secure RJ12 cable connections. Try a different RJ12 cable. Try a different port on the controller/splitter. Restart the Hydro-X system.
Lectures inexactesSensor placement issue; Dust/debris on sensor; Environmental interference.Relocate sensor to a more representative area. Clean the sensor gently. Ensure no strong air currents or heat sources are directly affecting the sensor.
No data displayedPower issue to controller; Cable disconnected; Sensor malfunction.Verify Hydro-X controller is powered on. Check all cable connections. If issues persist, contact support.

8. Especificacions

CaracterísticaDetall
ModelMBS-PRO
MidesTemperature, Humidity, CO2, Light Intensity
CompatibilitatTrolMaster Hydro-X Pro, Hydro-X Plus
ConnexióRJ12
ColorNegre
Pes16 unces (aprox. 0.45 kg)
MaterialPlàstic

9. Informació de la garantia

TrolMaster products are covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary. Please retain your proof of purchase. For detailed warranty information, refer to the official TrolMaster weblloc o contacteu amb el servei d'atenció al client.

Note: Unauthorized opening or modification of the device will void the warranty.

10. Atenció al client

If you encounter any issues or have questions regarding your TrolMaster MBS-PRO sensor that are not covered in this manual, please contact TrolMaster customer support for assistance.

  • Weblloc: Visit the official TrolMaster weblloc web amb preguntes freqüents, recursos d'assistència i informació de contacte.
  • Correu electrònic: Consulteu el weblloc web per obtenir l'adreça de correu electrònic d'assistència adequada.
  • Telèfon: Consulteu el weblloc web per a números de telèfon d'atenció al client.

© 2023 TrolMaster. Tots els drets reservats.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.