1. Introducció

The CAS DBI Weighing Indicator is designed for precise weight measurement in various applications, including open markets and retail environments. This indicator offers multiple functions such as counting, weight comparison, and percentage calculations, providing versatility for different weighing needs. This manual provides essential information for the proper setup, operation, and maintenance of your DBI Weighing Indicator.

CAS DBI Weighing Indicator connected to a platform scale with small metal parts being weighed.

Image: CAS DBI Weighing Indicator in operation with a platform scale.

2. Què hi ha a la caixa

  • 1 x CAS DBI Weighing Indicator

3. Configuració

  1. Desembalatge: Carefully remove the DBI Weighing Indicator from its packaging.
  2. Col·locació: Place the indicator on a stable, level surface. Ensure it is free from vibrations and direct sunlight.
  3. Connecting to Platform Scale: Connect the indicator to a compatible weighing platform scale using the appropriate cable (not included, typically supplied with the platform scale). Ensure the connection is secure.
  4. Connexió d'alimentació: Connect the provided power adapter to the indicator's DC input port and then to a suitable power outlet. The internal rechargeable battery will begin charging.
  5. Encesa inicial: Premeu el botó PODER button to turn on the indicator. Allow a few moments for the display to stabilize.
CAS DBI Weighing Indicator connected to a large platform scale, displaying 0.00 kg.

Image: DBI Weighing Indicator connected to a platform scale, ready for use.

4. Instruccions de funcionament

4.1 Operacions bàsiques

  • Encès/apagat: Premeu el botó PODER botó per encendre o apagar la unitat.
  • Pesatge bàsic:
    1. Ensure the indicator displays "0.00 kg" before placing any item on the connected platform. If not, press the ZERO botó.
    2. Place the item to be weighed on the center of the platform.
    3. Read the weight displayed on the LCD.
  • Funció de tara:
    1. Col·loqueu un contenidor buit a la plataforma.
    2. Premeu el botó TARA button. The display will show "0.00 kg" and the tare indicator will illuminate.
    3. Add items to the container; only the net weight will be displayed.
    4. To clear tare, remove the container and press TARA de nou.

4.2 Modes avançats

  • Mode de recompte: This mode allows for counting a large number of identical items. Follow the on-screen prompts to set a sample quantity, then place the items to get a total count.
  • Percenttage Mode: Use this mode to display the weight of an item as a percentage d'un pes de referència preestablert.
  • Accumulation Mode (Σ): This function enables the summing of multiple individual weighments. After each stable weighment, activate the accumulation function to add the weight to a running total.
  • Weight Comparison (HI/LOW/OK): Set upper (HI) and lower (LOW) weight limits. The indicator will visually or audibly signal if the current weight is above, below, or within the acceptable range.

4.3 Funcions addicionals

  • Pantalla de retroil·luminació: The large LCD display features a backlight (20mm character height) for improved visibility in various lighting conditions.
  • RS-232C Interface: Use the RS-232C port to connect the indicator to a compatible printer (e.g., DEP-50) or a computer for data transfer and ticket print-out.
  • Bateria recarregable: The indicator includes a rechargeable battery providing approximately 100 hours of operation. Charge the battery when the low battery indicator appears.
  • Apagat automàtic: The auto power off function conserves battery life by automatically shutting down the unit after a period of inactivity.

5. Característiques acabadesview

The CAS DBI Weighing Indicator is equipped with several features to enhance its functionality and user experience:

  • OIML Approval: Certified for 3,000 divisions, ensuring accuracy and reliability in commercial applications.
  • Pantalla LCD gran: A 20mm large LCD with backlight provides clear and easy-to-read weight indications.
  • Aplicacions versàtils: Designed for use with various bench and platform scales, making it suitable for diverse weighing tasks.
  • Advanced Weighing Modes: Includes Counting Mode for item quantity, Percentage Mode for comparative weighing, and Accumulation Mode for summing multiple weights.
  • Weight Comparison: Features HI/LOW/OK comparison function for efficient check-weighing against predefined limits.
  • Ticket Print-out (DEP-50 Compatible): Supports connection to a DEP-50 printer for generating physical records of weighments.
  • RS-232C Interface: Enables serial communication with external devices like printers or computers.
  • Llarga vida útil de la bateria: Integrated rechargeable battery offers approximately 100 hours of continuous operation.
  • Apagat automàtic: An energy-saving feature that automatically turns off the indicator after a period of inactivity.
Graphic detailing features of the CAS DBI Weighing Indicator including OIML approval, large LCD, various modes, and print-out options.

Image: Detailed features of the DBI Weighing Indicator.

6. Manteniment

  • Neteja: Wipe the indicator with a soft, damp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que no entri líquid a la unitat.
  • Cura de la bateria: For optimal battery life, charge the battery regularly and avoid deep discharges. If storing the unit for an extended period, ensure the battery is partially charged.
  • Emmagatzematge: Store the indicator in a dry, dust-free environment away from extreme temperatures.
  • Inspecció: Reviseu periòdicament els cables i les connexions per detectar qualsevol signe de desgast o dany.

7. Solució De Problemes

  • No Display/Unit Does Not Turn On:
    • Check power connection and ensure the adapter is securely plugged in.
    • Comproveu que la presa de corrent funcioni.
    • Ensure the rechargeable battery is not completely depleted; charge the unit for several hours.
  • Lectures inexactes:
    • Ensure the indicator and platform scale are on a stable, level surface.
    • Check for any obstructions under the platform.
    • Verify the platform scale is properly connected to the indicator.
    • Perform a zero calibration if necessary (refer to advanced calibration procedures, usually requiring a service technician or specific key sequence).
  • Display Shows "OVERLOAD" or "----":
    • Remove any excessive weight from the platform.
    • Ensure the platform scale's capacity is not exceeded.
  • Botons que no responen:
    • Assegureu-vos que la unitat estigui encès.
    • Restart the indicator by turning it off and then on again.
    • Si el problema persisteix, poseu-vos en contacte amb el servei d'atenció al client.

8. Especificacions

EspecificacióDetall
MarcaCAS
Número de modelDBI_Indicator
ColorNegre
Característica especialAuto Shut Off, Backlit Display
Tipus de visualitzacióLCD
Factor de formaMini
MaterialEstirol acrilonitril butadiè
Tipus de bàsculaEscala de comptador
Pes de l'article1 kg 500 g
Dimensions del producte (LxWxH)14.5 x 27.8 x 18.7 cm
Font d'alimentacióDC
Components inclosos1 Weighing indicator
Durada de la bateria (aprox.)100 hores
OIML Approval3,000 divisions
Technical drawing showing the dimensions of the CAS DBI Weighing Indicator in millimeters.

Image: Dimensions of the DBI Weighing Indicator.

9. Garantia i Suport

Garantia: For warranty information, please refer to the documentation provided at the time of purchase or contact CAS customer service directly.

Atenció al client: For technical assistance, service, or spare parts, please contact CAS Weighing India Pvt Ltd.

  • Telèfon: +91-9212559707
  • Adreça: Plot No. 788, Udyog Vihar, Phase -V, Gurugram, Haryana -122016 INDIA
CAS DBI Weighing Indicator with text 'RETAIL WEIGHING SOLUTION' and contact information for CAS Weighing India Pvt Ltd.

Image: CAS DBI Indicator for retail weighing solutions, showing contact details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.