DIGITEN DTC-310
Manual d'usuari del controlador de temperatura impermeable DIGITEN DTC310
Model: DTC-310
1. Introducció
This manual provides comprehensive instructions for the installation, operation, and maintenance of your DIGITEN Waterproof Temperature Controller DTC310. This device is designed to precisely regulate temperature in various environments, ensuring optimal conditions for your applications. Please read this manual thoroughly before use to ensure safe and efficient operation.

Image 1.1: DIGITEN DTC310 Waterproof Temperature Controller. This image shows the main unit with its display, control buttons, power cord, and sensor probe, all designed to withstand water exposure.
The DTC310 controller is suitable for a wide range of applications including:
- Greenhouses and mushroom houses
- Reptile breeding and pet feeding enclosures
- Aquariums and fish tanks
- Wine cellars and cigar storage
- Home brewing and fermentation
- Seed germination and heating mats
- Baby rooms, attics, garages, and other general temperature control needs

Image 1.2: Diverse applications of the DTC310. This image illustrates the controller being used in an aquarium, for incubation, seedling growth, greenhouse, mushroom cultivation, and homebrewing.
2. Producte acabatview
2.1 Components
The DIGITEN DTC310 Waterproof Temperature Controller consists of the main control unit, a sensitive waterproof sensor probe, a standard US plug for power input, and a 3-pin socket for connecting your heating or cooling device.

Image 2.1: Labeled components of the DTC310. This image highlights the Current Temp (PV), Run Temp (RV), Stop Temp (SV) on the display, along with the Run Indicator, Stop Indicator, Setting Button, Up Button, Down Button, Sensitive Probe with Suction Cup, Standard US Plug, and 3-Pin Socket.
2.2 Característiques clau
- Wide Temperature Control Range: Regulates and maintains temperatures from -40°F to 248°F (-40°C to 120°C).
- Classificació impermeable IP65: The integrated waterproof shell allows for outdoor use, protecting against rain. For optimal waterproofing, hanging the unit is recommended.
- Pantalla LED il·luminada: Provides clear temperature readings and settings, even in low-light conditions.
- Alarmes d'alta i baixa temperatura: Alerts users if the temperature exceeds or falls below a set range, protecting connected devices or environments.
- Unitats commutables: Canvia fàcilment entre Fahrenheit (°F) i Celsius (°C).
- Calibració de temperatura: Allows for fine-tuning of temperature readings for accuracy.
- Protecció de retard del compressor: Customizable delay settings protect refrigeration equipment from frequent on/off cycles.

Image 2.2: Key features of the DTC310. This image highlights the Heating/Cooling Mode, °C/°F Switchable function, Calibration capability, and High/Low Temperature Alarm.
3. Configuració
3.1 Instal·lació física
The controller can be mounted on a wall or hung using hooks. Ensure the installation location is stable and allows for easy access to the display and buttons.

Image 3.1: Controller hanging installation. This image shows the DTC310 unit hanging from hooks, demonstrating a common installation method.
3.2 Sensor Probe Placement
The waterproof sensor probe is crucial for accurate temperature readings. Place the probe in the environment where temperature control is needed. For aquariums, use the included suction cup to secure the probe within the water. Ensure the probe is fully submerged or positioned to accurately reflect the target temperature.

Image 3.2: Sensor probe with suction cup. This image details the sensitive probe and its suction cup attachment for secure placement.
3.3 Connexió d'alimentació
Plug the controller's standard US plug into a suitable power outlet. Connect your heating or cooling device to the 3-pin socket located at the bottom of the controller. Ensure the device connected does not exceed the controller's maximum current rating of 10A.

Image 3.3: 3-pin power socket. This image shows a detailed view of the power output socket where the heating or cooling device is connected.
4. Instruccions de funcionament
The DTC310 features an intuitive interface with a SET button, an Up button, and a Down button for configuration.
4.1 Mostra finalview
The LED display shows three main values:
- VA (Valor del Procés): Current temperature detected by the probe.
- RV (Run Value): The temperature at which the connected device will activate (e.g., heater turns on, cooler turns off).
- SV (Stop Value): The temperature at which the connected device will deactivate (e.g., heater turns off, cooler turns on).
Indicators for 'Run' and 'Stop' will illuminate to show the status of the connected device.
4.2 Setting Temperature Parameters
Follow these steps to configure the temperature settings:
- Switching °F or °C: Premeu el botó Up i Avall buttons simultaneously to toggle between Fahrenheit and Celsius.
- Enter Preset Mode: Manteniu premut el botó SET button for 3 seconds to enter the temperature preset mode.
- Set Run Temperature (RV): Utilitza el Up or Avall buttons to adjust the desired Run Temperature.
- Set Stop Temperature (SV): Premeu breument SET button to move to the Stop Temperature setting. Use the Up or Avall buttons to adjust the desired Stop Temperature.
- Desa la configuració: Manteniu premut el botó SET button for 3 seconds to save your settings and exit the preset mode.

Image 4.1: Temperature setting guide. This image visually demonstrates the four steps to set the temperature parameters on the DTC310 controller.
4.3 Advanced Settings (P0-P8 Parameters)
The DTC310 may include advanced parameters for fine-tuning operation, such as compressor delay, temperature calibration, and alarm thresholds. Refer to the detailed parameter list below for specific functions and adjustment methods. To access these settings, typically a longer press of the SET button or a combination of buttons is required.
| Paràmetre | Descripció | Interval | Per defecte |
|---|---|---|---|
| P0 | Mode de calefacció/refrigeració | H (Heating) / C (Cooling) | H |
| P1 | Hysteresis Setting | 0.1-30 °F (0.1-15 °C) | 2 °C (1 °F) |
| P2 | Alarma d'alta temperatura | -40-248 °C (-40-120 °F) | 248 °C (120 °F) |
| P3 | Alarma de baixa temperatura | -40-248 °C (-40-120 °F) | -40 °F (-40 °C) |
| P4 | Calibració de la temperatura | -10-10 °C (-5-5 °F) | 0 °C (0 °F) |
| P5 | Retard del compressor | 0-10 minuts | 0 minuts |
| P6 | Selecció d'unitats | F (Fahrenheit) / C (Celsius) | F |
| P7 | Bloqueig de dades | ON / OFF | OFF |
| P8 | Restabliment de fàbrica | SÍ / NO | NO |
To access advanced parameters: Long press the SET botó i el Up button simultaneously for 3 seconds. Use Up/Avall to navigate parameters (P0-P8). Press SET to enter a parameter, adjust with Up/Avall, després premeu SET again to confirm. Long press SET per sortir.
5. Manteniment
Regular maintenance ensures the longevity and accuracy of your DIGITEN DTC310 Temperature Controller.
- Neteja: Netegeu la unitat de control amb un drap suauamp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que la unitat estigui desendollada abans de netejar-la.
- Cura de la sonda: Keep the sensor probe clean and free from debris or mineral buildup, especially when used in water. Gently clean the probe with a soft brush if necessary.
- Inspecció del cable: Periodically check all cables for any signs of wear, cuts, or damage. Replace the unit if any damage is found to prevent electrical hazards.
- Emmagatzematge: If storing the controller for an extended period, ensure it is clean, dry, and stored in a cool, dry place away from direct sunlight.
6. Solució De Problemes
If you encounter issues with your DTC310 controller, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla està apagada | Sense font d'alimentació | Check if the controller is properly plugged into a live power outlet. Verify the outlet is functional. |
| Connected device (heater/cooler) is not turning on/off | Incorrect temperature settings (RV/SV) Device not properly plugged into controller Controller in wrong mode (Heating/Cooling) Compressor delay active | Review and adjust RV/SV settings. Ensure the device is securely plugged into the controller's socket. Check P0 parameter for correct mode. Wait for compressor delay to expire (P5). |
| Lectura de temperatura inexacta | Sensor probe dirty or improperly placed Cal calibratge | Clean the sensor probe and ensure it is correctly positioned. Perform temperature calibration using the P4 parameter. |
| Alarm constantly active | Temperature outside set alarm limits Alarm limits set too close to operating range | Check the current temperature and adjust the P2 (High Alarm) and P3 (Low Alarm) parameters to appropriate values. |
| Els botons no responen | Error temporal de programari Data lock enabled | Unplug the controller for 10 seconds and plug it back in. Check P7 parameter to ensure Data Lock is OFF. |
Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb l'atenció al client.
7. Especificacions
| Característica | Especificació |
|---|---|
| Número de model | DTC-310 |
| Interval de control de temperatura | -40 °F a 248 °F (-40 °C a 120 °C) |
| Potència nominal | 10A |
| Classificació impermeable | IP65 |
| Tipus de visualització | LED |
| Pes de l'article | 14.9 unces |
| Dimensions del paquet | 7.05 x 3.5 x 3.31 polzades |
| UPC | 727567973164 |
8. Garantia i Suport
8.1 Informació de la garantia
The DIGITEN DTC310 Waterproof Temperature Controller comes with a 12 mesos de garantia from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, accidents, unauthorized modifications, or improper installation.
8.2 Atenció al client
For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact DIGITEN customer support. Refer to the product packaging or the official DIGITEN weblloc web per obtenir la informació de contacte més actualitzada.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.



