1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of your Aideepen LCD Digital AC Power Meter, model PZEM-022. This 6-in-1 device is designed to accurately measure and display various electrical parameters for household and industrial applications. Please read this manual thoroughly before use to ensure safe and correct operation.

2. Característiques clau

The Aideepen PZEM-022 power meter offers comprehensive monitoring capabilities:

  • Mesura 6 en 1: Simultaneously displays Voltage (AC 80-260V), Current (0-100A), Power (0-22000W), Energy Consumption (0-999kWh), Frequency (45-65 Hz), and Power Factor (0-1PF).
  • Control de la llum de fons: Easily toggle the LCD backlight on or off with a short button press. Data is automatically saved when the backlight is off.
  • Overload Alarm Function: Set a current alarm threshold. The backlight will flash to indicate an overload condition. The alarm stops when the current drops below the threshold.
  • Energy Data Reset: A dedicated function allows for clearing accumulated energy consumption data.
  • Emmagatzematge de dades: Automatically stores measurement data even when power is off.
Aideepen LCD Digital AC Power Meter display showing Voltage, Current, Power, Energy, Frequency, and Power Factor readings with their respective ranges.

Figura 2.1: Mésview of the meter's display showing all 6 measurement parameters and their ranges.

3. Informació de seguretat

Si us plau, observeu les següents precaucions de seguretat per evitar danys al dispositiu o lesions personals:

  • Càrrega nominal: Ensure that the electrical load connected to the circuit does not exceed the rated power capacity of the meter (22000W) or the current transformer (100A).
  • Cablejat correcte: Always follow the provided wiring diagram precisely. Incorrect wiring can lead to device malfunction, electrical shock, or fire.
  • Només per a ús interior: This product is designed for indoor use in dry environments. Do not install or operate this device outdoors or in damp condicions.
  • Instal·lació professional: If you are not familiar with electrical wiring, seek assistance from a qualified electrician for installation.
  • Desconnexió d'alimentació: Always disconnect power to the circuit before performing any installation, wiring, or maintenance.

4. Contingut del paquet

Verifiqueu que tots els elements siguin presents al paquet:

  • 1 x Aideepen LCD Digital AC Power Meter (PZEM-022)
  • 1 x Current Transformer (CT)
  • 1 x Manual d'usuari
The Aideepen LCD Digital AC Power Meter and its accompanying current transformer (CT clamp).

Figure 4.1: The power meter unit and the current transformer.

5. Configuració i instal·lació

Follow these steps for proper installation of the power meter:

  1. Desconnecteu l'alimentació: Before starting any wiring, ensure that the main power supply to the circuit is completely disconnected to prevent electrical shock.
  2. Mount the Meter: Choose a suitable indoor location for the meter. The meter is designed for panel mounting.
  3. Connecteu la font d'alimentació: Connect the AC 80-260V power supply to the meter's input terminals as shown in the wiring diagram. Ensure correct polarity if applicable, though for AC, line and neutral are typically interchangeable for the meter's power input.
  4. Install Current Transformer (CT):
    • Identify the load wire (live wire) of the circuit you wish to monitor.
    • Open the CT clamp and pass only the load wire through the center hole of the CT. Ensure the arrow on the CT points in the direction of current flow (from source to load).
    • Connect the two wires from the CT clamp to the CT input terminals on the meter.
  5. Verifica les connexions: Double-check all wiring connections against the diagram to ensure they are secure and correct.
  6. Restaura l'alimentació: Once all connections are verified, restore power to the circuit. The meter display should light up.
Wiring diagram showing connections for the Aideepen AC Power Meter, including power supply, load, and current transformer (CT).

Figure 5.1: Wiring Diagram. Disconnect power before wiring.

Comparison of an open-design current transformer (CT) and a closed-type CT, highlighting the ease of use of the open design.

Figure 5.2: The open-design current transformer allows for easy installation without cutting the main wire.

6. Instruccions de funcionament

The meter is designed for straightforward operation. Once powered on, it will immediately begin displaying real-time measurements.

6.1. Control de la llum de fons

To control the display backlight:

  • Activar/Desactivar: Briefly press the button located on the front panel. Each press will toggle the backlight state.
  • Estalvi de dades: The meter automatically saves measurement data regardless of the backlight status.

6.2. Overload Alarm Setting

To set or adjust the current overload alarm threshold:

  1. Entra al mode de configuració: Press and hold the button for approximately 3 seconds until the current alarm threshold value starts flashing on the display.
  2. Adjust Threshold: While the value is flashing, briefly press the button to increase the threshold value. The value will cycle through available settings.
  3. Desa la configuració: Stop pressing the button. After 3 seconds of inactivity, the meter will automatically save the new threshold and exit the setting mode.

When the measured current exceeds the set threshold, the backlight will flash to alert you of an overload condition. The flashing will stop once the current drops below the threshold.

6.3. Energy Data Reset

To clear the accumulated energy consumption (kWh) data:

  1. Inicia el restabliment: Press and hold the button for 5 seconds until the energy consumption number starts flashing. Then release the button.
  2. Confirmeu el restabliment: Briefly press the button again. This action will clear the energy data and stop the flashing.
  3. Cancel Reset: If no button operation occurs within 5 seconds after the number starts flashing, the reset will be canceled, and the energy data will remain unchanged.
Aideepen LCD Digital AC Power Meter display with icons representing Overload Alarm, Backlight Control, Reset Energy Data, Data Storage, and Power Alarm Setting.

Figure 6.1: Icons illustrating key functions of the meter.

7. Manteniment

The Aideepen PZEM-022 power meter requires minimal maintenance:

  • Neteja: Feu servir un drap suau i sec per netejar la pantalla iasing. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Medi ambient: Ensure the meter is kept in a dry, dust-free environment within its specified operating temperature range.
  • Inspecció: Comproveu periòdicament les connexions del cablejat per comprovar si estan ben ajustades i si hi ha signes de desgast o danys.

8. Solució De Problemes

If you encounter issues with your power meter, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
La pantalla està en blancNo hi ha alimentació o cablejat incorrecte.Check the AC 80-260V power connections to the meter. Ensure power is supplied to the circuit.
Current/Power readings are zero or incorrectCT clamp not installed correctly or connected to the wrong wire.Ensure the load wire passes through the CT clamp and the CT is connected to the meter. Verify the arrow on the CT points from source to load.
Backlight flashing continuouslyOverload alarm triggered.Reduce the load on the circuit or adjust the overload alarm threshold if necessary (refer to Section 6.2).
Energy consumption resets unexpectedlyEnergy consumption exceeded 999kWh, or accidental reset.The meter automatically resets if 999kWh is exceeded. Be careful when using the reset function (Section 6.3).

9. Especificacions

ParàmetreValor
Número de modelPZEM-022
Vol. OperatiutageAC 80-260V
Interval actual0-100A
Potència0-22000W
Energy Consumption Range0-999kWh (resets after 999kWh)
Interval de freqüència45-65 Hz
Interval del factor de potència0-1PF
Tipus de visualitzacióLCD amb llum de fons
Dimensions del producte (L x A x A)11 x 7 x 3.5 cm
Pes de l'article160 grams
CertificacionsCE
Components inclososAmmeter *1, User Manual *1
Diagram showing the dimensions of the Aideepen LCD Digital AC Power Meter in centimeters and inches.

Figura 9.1: Dimensions del producte.

10. Garantia i Suport

Aideepen products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official Aideepen weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.