1. Introducció
This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 1000 AT FR Online Uninterruptible Power Supply (UPS). The VFI AT series utilizes double-conversion technology to provide reliable power protection for critical devices. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Instruccions de seguretat
WARNING: Failure to follow these safety instructions can result in fire, electric shock, serious injury, or death.
- No obriu el SAI casing. No hi ha peces a l'interior que l'usuari pugui reparar. Demaneu totes les tasques de manteniment a personal de servei qualificat.
- Do not connect appliances that could overload the UPS, such as hair dryers or vacuum cleaners.
- Ensure the UPS is connected to a properly grounded power outlet.
- Do not block ventilation openings. Maintain adequate clearance around the UPS for proper airflow.
- Avoid installing the UPS in areas with excessive dust, humidity, or extreme temperatures.
- In case of emergency, press the OFF button and disconnect the UPS from the AC power source.
3. Producte acabatview
The PowerWalker VFI 1000 AT FR UPS is designed to provide clean, stable power to your connected equipment. It features a user-friendly interface and various connectivity options.
3.1 Tauler frontal

Figure 3.1: Front Panel of the UPS. This image shows the main display screen indicating input and output voltage, battery status, and load level. Below the screen are four control buttons: ON, OFF, ENTER, and ESC.
The front panel includes an LCD display that provides real-time information about the UPS status, such as input/output voltage, battery charge, and load level. Control buttons allow for easy navigation and configuration.
- Pantalla LCD: Mostra l'estat i els paràmetres de funcionament.
- Botó ON: Powers on the UPS.
- Botó OFF: Apaga el SAI.
- Botó ENTER: Confirma seleccions o accedeix a menús.
- Botó ESC: Surt dels menús o cancel·la operacions.
3.2 Panell posterior

Figure 3.2: Rear Panel of the UPS. This image displays the connectivity options including a serial port (DB9), cooling fan, multiple Type F outlets, a USB port, an EPO (Emergency Power Off) terminal, and the AC input socket.
The rear panel provides all necessary connections for input power, output to protected devices, and communication interfaces.
- Entrada de CA: Connecta el SAI a la font d'alimentació principal.
- Endolls de sortida: Type F, Type E, or Type G outlets (depending on model) for connecting protected equipment.
- Port USB: For communication with a computer and monitoring software.
- RS-232 Port (Serial): For advanced communication and monitoring.
- EPO (Emergency Power Off) Terminal: Per a l'aturada d'emergència remota.
- Ranura intel·ligent: Per a targetes de comunicació opcionals (per exemple, targeta SNMP).
- Connector de la bateria externa: For connecting optional external battery packs to extend backup time.
4. Configuració
4.1 Desembalatge i inspecció
Carefully unpack the UPS and inspect it for any shipping damage. If any damage is found, do not install the unit and contact your dealer.
4.2 Col·locació
Place the UPS in a clean, dry, and well-ventilated area. Ensure sufficient clearance (at least 20 cm) around the unit for proper heat dissipation. Avoid direct sunlight, heat sources, and excessive moisture.
4.3 Càrrega inicial
Before initial use, connect the UPS to a standard AC power outlet for at least 8 hours to ensure the internal batteries are fully charged. The UPS will charge its batteries whether it is turned ON or OFF.
4.4 Equips de connexió
- Connect your critical equipment (computers, monitors, network devices) to the output sockets on the rear panel of the UPS.
- Connect the UPS power cord to a grounded AC power outlet.
- (Optional) Connect the USB or RS-232 cable from the UPS to your computer for monitoring and management.
- (Optional) If using external battery packs, connect them according to their specific instructions to the designated connector on the UPS.
5. Funcionament del SAI
5.1 Engegar el SAI
Manteniu premut el botó ON button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates. The UPS will perform a self-test and then enter normal operating mode.
5.2 Apagada del SAI
To turn off the UPS, press and hold the OFF button for approximately 2 seconds until the LCD display turns off. Ensure all connected equipment is properly shut down before turning off the UPS.
Pantalla LCD 5.3 i navegació
The LCD display provides various operational parameters. Use the ENTRAR i ESC buttons to navigate through menus and view different information screens. The display automatically darkens after a period of inactivity and can be woken up with a single button press.
5.4 Remote Shutdown (RPO)
The UPS supports Remote Power Off (RPO) functionality. Connect an external switch to the EPO terminal on the rear panel. Activating this switch will immediately shut down the UPS and connected equipment. Refer to the wiring diagram in the advanced user manual for proper connection.
6. Manteniment
6.1 Cura de la bateria
The UPS contains internal lithium batteries. To maximize battery life:
- Keep the UPS connected to AC power to keep batteries charged.
- Avoid storing the UPS in extreme temperatures.
- Perform a battery calibration (if available via software) or a full discharge/recharge cycle every 3-6 months.
- Replace batteries when their capacity significantly degrades. Battery replacement should only be performed by qualified personnel.
6.2 Neteja
Netegeu l'exterior del SAI amb un drap suau i sec. No utilitzeu netejadors líquids ni en aerosol. Assegureu-vos que les obertures de ventilació estiguin lliures de pols i deixalles.
6.3 Emmagatzematge
If storing the UPS for an extended period, ensure the batteries are fully charged. Recharge the batteries every three months to prevent permanent damage.
7. Solució De Problemes
This section provides solutions to common issues you may encounter with your UPS. If the problem persists, contact technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| El SAI no s'encén. | No AC input power; Low battery charge. | Check AC power connection; Allow UPS to charge for 8 hours. |
| El SAI emet un so continu. | Overload; Low battery; Fault condition. | Reduce connected load; Allow batteries to charge; Check LCD for error codes. |
| Temps de còpia de seguretat curt. | Batteries not fully charged; Batteries reaching end of life. | Ensure full charge; Consider battery replacement. |
| Connected equipment not receiving power. | UPS is off; Output sockets not enabled; UPS in fault mode. | Turn on UPS; Check LCD for status; Consult manual for output settings. |
8. Especificacions
| Característica | Detall |
|---|---|
| Model | VFI 1000 AT FR (Model Number: 10122183) |
| Marca | PowerWalker |
| Capacitat de potència de sortida | 900W |
| Entrada Voltage | 220V (Wide input voltagrang e) |
| Tipus de bateria | Liti |
| Endolls de sortida | Type F, Type E, Type G (various versions available) |
| Ports de comunicació | USB (HID support), RS-232, Intelligent Slot |
| Dimensions (A x A x P) | 50 x 10 x 48 cm (aproximadament) |
| Pes | 2 quilos |
| Característiques especials | Double-conversion online technology, Generator compatible, RPO, External battery pack support, Automatically darkening LCD. |
9. Garantia i Suport
The PowerWalker VFI 1000 AT FR UPS is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official PowerWalker weblloc web per obtenir informació detallada sobre els termes i condicions de la garantia.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact your local dealer or PowerWalker customer service. The EU Spare Part Availability Duration is 2 Years.