Producte acabatview
The Micsig SATO1004 is a 4-channel automotive digital oscilloscope featuring an 8-inch touch screen, 100MHz bandwidth, a maximum 1GSa/s sampling rate, and up to 70Mpts of memory depth. Designed for automotive diagnostics, it supports various tests including ignition, sensors, actuators, networks, charging circuits, starter circuits, and communication protocols like CAN, LIN, FlexRay, and K-line. It also includes 32GB of internal storage for waveforms, screenshots, and recorded videos, and is highly portable with a built-in 7500mAh Li-ion battery providing 4-5 hours of operation.

Figura 1: Frontal view of the Micsig SATO1004 Automotive Digital Oscilloscope displaying various waveforms on its 8-inch touch screen.
Què hi ha a la caixa
The standard kit for the SATO1004 includes the following components:
- 1 x SATO Series Automotive Oscilloscope (built-in battery)
- 2 x Passive Probes
- 2/4 x BNC-Banana Cables (quantity may vary by kit)
- 1/2 Pair x Alligator Clips (quantity may vary by kit)
- 1/2 Pair x Soft Pin Probes (quantity may vary by kit)
- 1 x protector de pantalla
- 1 x adaptador de corrent
- 1 x Power Cord (localized)
- 1 x Quick Guide Collection

Figure 2: All accessories included in the standard SATO1004 kit, neatly arranged in their packaging.
Configuració
- Desembalatge i inspecció: Upon receiving the Micsig SATO1004, inspect the outer packaging for any signs of damage before opening.
- Verifica el contingut: Open the box and verify all contents against the packing list. Ensure the Calibration Certificate, Packing List, Quick Guide, and QC Pass are present.
- Remove Protective Plastic: Carefully remove the sealed plastic film from the oscilloscope. Important: Do not turn on the oscilloscope with the sealed plastic on, as it will block the heat dissipation from the fan located at the back.
- Power Switch Lock: Locate the power switch lock on the device. By default, it is set to OFF to prevent accidental power-on during transit. Slide the switch to the ON position.
- Encès: Press the power button to turn on the oscilloscope. The power indicator light will illuminate.
- Adjust Back Stand: Open the back stand until you hear a click, ensuring the oscilloscope sits solidly on a flat surface for stable operation.
Video 1: This official Micsig video provides a comprehensive guide to unboxing the SATO1004, identifying its interfaces, introducing accessories, demonstrating probe calibration, and showcasing basic signal measurement. It covers the initial setup steps in detail.
Interfície acabadaview:
The SATO1004 features several interfaces for connectivity and functionality:
- Botó d'encesa: Per encendre/apagar el dispositiu.
- Grounding Jack: Per a una correcta connexió a terra del dispositiu.
- Probe Calibration Port: Used for calibrating oscilloscope probes.
- USB 2.0 and USB 3.0 Connectors: For connecting external USB devices.
- Port HDMI: Per connectar a una pantalla externa.
- Port USB tipus C: Per a la transferència de dades i la càrrega.
- Port d'alimentació DC 12V: Entrada d'alimentació principal.

Figura 3: posterior view of the SATO1004, highlighting the foldable stand and the array of input/output ports for connectivity.
Instruccions de funcionament
Calibració de la sonda:
Proper probe calibration is crucial for accurate measurements. Follow these steps:
- Connect the BNC probe to Channel 1 on the oscilloscope. Rotate the metal ring on the probe connector to secure it.
- Press the probe head to extend the hook.
- Connect the hook to the calibration port on the oscilloscope. Ensure the lower part of the calibration port (output) is connected to the probe tip and the upper part (ground) is connected to the probe's ground clip.
- Press the "AUTO" button on the oscilloscope. The device will automatically adjust settings to display a square waveform.
- Observe the waveform. If it shows overcompensation (rounded top corners) or undercompensation (slanted top corners), the probe needs calibration.
- Locate the screw stick in the probe kit. Insert it into the small hole on the probe connector and slowly rotate to adjust until the waveform displays a flat, clean square edge.
- For easy identification, you can fit the probe with a color ring that matches the channel color on the oscilloscope.
Measuring Signals:
When testing signals, try to use a short ground lead as possible, such as the ground pogo pin. The ground connection should be close to the signal source to greatly reduce interference and improve signal fidelity.
- Pin Probe: The pin probe can pierce the sensor signal line for direct measurement.
- Pinces de cocodril: Alligator clips are typically used for grounding connections.
- BNC to Banana Cable: Connect a BNC to Banana cable to any channel. The banana head can be connected to a pin probe or an alligator clip depending on the measurement requirement.
CAN FD Bus Decoding:
The SATO1004 supports CAN FD bus decoding for advanced automotive diagnostics.
- Connect the CAN FD bus signal to the oscilloscope.
- Open the serial bus menu on the oscilloscope's touch screen.
- Select "CAN FD" from the available options.
- According to the input signal, set the Source, Signal, Baud rate, and Sampposició de la llengua.
- Set the trigger to "Bus decoding".
- Adjust the Level to the middle of the waveform and set the time base and vertical scale to the proper position to clearly view the decoded data.
- Tu pots view the decoded data directly on the screen.
- To record data, open TXT mode. This mode can record all the data.
- Click "QuickSave" to save the decoded data to a CSV file per a una anàlisi posterior.
Automotive Diagnostic Presets:
The SATO1004 comes with various pre-configured settings for common automotive diagnostic tests, simplifying setup and analysis:
- Encesa primària
- cigonyal
- Bus CAN
- Posició de l'accelerador
- Variable-speed cooling Fan
- Start/Charging Current
- Arbre de lleves
- Carbon Canister Solenoid Valve
- Mesurador de cabal d'aire
- Regulador de pressió
- Alternator AC Ripple
- Injector (Diesel)
- CAN H&L
- Camshaft + Crankshaft Combination
- Phase Rulers

Figure 4: The SATO1004's interface displaying a selection of automotive diagnostic presets for quick and efficient testing.
Manteniment
To ensure the longevity and optimal performance of your Micsig SATO1004 oscilloscope, follow these maintenance guidelines:
- Neteja: Use a soft, dry cloth to clean the exterior of the oscilloscope. For the touch screen, use a screen-specific cleaning solution and a microfiber cloth. Avoid abrasive cleaners or solvents that could damage the display or casing.
- Emmagatzematge: Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When not in use, ensure the back stand is folded and the device is placed in its protective packaging or a suitable carrying case.
- Cura de la bateria: The built-in 7500mAh Li-ion battery provides 4-5 hours of operation. For optimal battery life, avoid fully discharging the battery frequently. Charge the device regularly, and if storing for extended periods, ensure the battery is charged to about 50-70%.
- Ventilació: Ensure the fan vents on the back of the oscilloscope are clear of obstructions to allow for proper heat dissipation. This is critical for preventing overheating and maintaining performance.
- Cura de la sonda: Handle probes carefully. Store them properly to prevent damage to the tips and cables. Calibrate probes regularly as demonstrated in the operating instructions to ensure measurement accuracy.
- Actualitzacions de programari: Connect to Wi-Fi and open the AppMarket to download WPS (Wireless Protection Setup) and other software updates. Regularly updating the device's software ensures access to the latest features, bug fixes, and performance improvements.
Resolució de problemes
This section provides solutions to common issues you might encounter with your Micsig SATO1004 oscilloscope.
Issue: Device does not power on.
- Solució 1: Check the power switch lock. Ensure it is slid to the "ON" position. It is set to OFF by factory to prevent accidental turn-on.
- Solució 2: Verify the battery charge. Connect the oscilloscope to the power adapter and allow it to charge for some time before attempting to power on again.
- Solució 3: Ensure the power adapter and power cord are securely connected to both the oscilloscope and a working power outlet.
Issue: Waveforms are distorted or inaccurate.
- Solució 1: Perform probe calibration as detailed in the "Operating Instructions" section. Incorrect probe compensation is a common cause of waveform distortion.
- Solució 2: Ensure the probe's ground lead is connected as close as possible to the signal source to minimize interference.
- Solució 3: Check the probe's attenuation setting (e.g., 1X, 10X) on the probe itself and ensure it matches the setting on the oscilloscope channel.
- Solució 4: Adjust the vertical scale (Volts/Div) and time base (Sec/Div) settings to properly display the waveform. Use the "AUTO" button for an initial automatic setup.
Issue: Device overheats.
- Solució 1: Ensure the sealed plastic film has been completely removed from the device, especially from the fan area on the back.
- Solució 2: Check that the fan vents are not obstructed by anything (e.g., clothing, papers, dust). Ensure adequate airflow around the device.
- Solució 3: Operate the device in a well-ventilated area and avoid direct sunlight or other heat sources.
Issue: Cannot save data or access files.
- Solució 1: Check the internal storage. Ensure there is sufficient free space on the 32GB internal storage.
- Solució 2: If saving to an external USB drive, ensure the drive is properly formatted and connected to one of the USB ports (USB 2.0 or USB 3.0).
- Solució 3: For CSV file access, ensure you have downloaded a compatible application like WPS from the AppMarket and that the file is saved in the correct directory.
Especificacions
| Característica | Especificació |
|---|---|
| Model | SATO1004 |
| Canals | 4 |
| Ample de banda | 100 MHz |
| Max SampTarifa ling | 1GSa/s |
| Profunditat de memòria | 70 Mpts |
| Mostra | Pantalla tàctil de 8" |
| Emmagatzematge intern | 32 GB |
| Bateria | 7500mAh Li-ion (4-5 hours battery life) |
| Fabricant | Micsig |
| Data de primera disponibilitat | 20 d'abril de 2023 |
| ASIN | B0C33PGLSN |
Garantia i Suport
For detailed warranty information and technical support, please visit the official Micsig website or contact their customer service. The manufacturer, Micsig, is committed to providing high-quality signal test and measurement instruments.
Micsig Official Weblloc: www.micsig.com
For any inquiries or assistance, refer to the contact information provided on the official weblloc web o la documentació de la compra.