GAIN EXPRESS PHC-342_EU

GAIN EXPRESS PHC-342_EU Digital pH/ORP/Temperature 3-in-1 Water Quality Controller User Manual

Model: PHC-342_EU

1. Introducció

This manual provides comprehensive instructions for the GAIN EXPRESS PHC-342_EU Digital pH/ORP/Temperature 3-in-1 Water Quality Controller. This device is designed for precise and continuous monitoring of pH, Oxidation-Reduction Potential (ORP), and temperature in various water environments. Featuring Wi-Fi connectivity, it allows for remote data access, real-time monitoring, and control of external devices through its output relays. Please read this manual thoroughly before operation to ensure proper use and optimal performance.

2. Contingut del paquet

  • 1 x 3-in-1 Controller Unit
  • 1 sonda de pH
  • 1 sonda ORP
  • 1 x sonda de temperatura
  • 3 x pH Buffer Powders (pH 4.0, pH 6.86, pH 9.18)
  • 1 x ORP Buffer Powder (256 mV)
  • 2 x ventoses
  • 4 x cargols
  • 1 x font d'alimentació
  • 1 x Manual d'instruccions en anglès
Full package contents of the GAIN EXPRESS PHC-342_EU controller

This image shows all components included in the package: the main controller unit, pH and ORP probes, temperature probe, buffer powders, suction cups, screws, power supply, and the instruction manual.

3. Característiques clau

  • Control intel·ligent de Wi-Fi: Compatible with iOS and Android systems for remote viewing of current and historical pH/ORP data.
  • Monitorització 24/7: Continuous online monitoring and control capabilities for pH and ORP.
  • Output Power Relays: Connect external devices (e.g., oxygen pump, CO2 regulator, O3 ozonizer) to pH or ORP output sockets.
  • Interfície fàcil d'utilitzar: Separate electrodes for pH, ORP, and temperature ensure quick response and stable readings. Backlight control for easy viewing.
  • Alarmes personalitzables: Set upper and lower pH/ORP limits via the mobile application; receive smartphone notifications when limits are exceeded.
  • Registre de dades: Access and analyze historical data curves for pH and ORP over the last 30 days within the app.
  • High-Precision Replaceable Electrodes: Quick response and stable readings. Standard BNC connectors allow for easy replacement of pH or ORP probes.
  • Disseny de muntatge a la paret: Instal·lació convenient.
  • Easy 3-Point pH Calibration: Simplifies the calibration process.
  • Mesura simultània: Displays pH, ORP, and Temperature concurrently on the LCD.

4. Configuració i instal·lació

Follow these steps to set up your GAIN EXPRESS PHC-342_EU controller:

  1. Muntatge del controlador: Use the provided screws and suction cups to mount the controller unit and the power outlet module in a suitable location. Ensure it is away from direct water splashes. The wall mount design allows for secure placement.Wall mount design of the controller

    This image illustrates the wall mount design of the controller unit, showing the mounting holes and the separate power outlet module.

  2. Connecting the Probes:
    • Connect the pH probe to the BNC connector labeled "pH" on the controller.
    • Connect the ORP probe to the BNC connector labeled "ORP" on the controller.
    • Connect the temperature probe to the jack labeled "TEMP" on the controller.
    pH and ORP electrodes with BNC connector and temperature probe

    This image displays the pH and ORP electrodes, highlighting their BNC type connectors, and the temperature probe with its jack.

  3. Placing the Probes: Submerge the pH, ORP, and temperature probes into the water body you wish to monitor (e.g., aquarium, hydroponic system). Ensure the probes are fully immersed and securely positioned.Controller setup in an aquarium with probes submerged

    This image shows the GAIN EXPRESS controller connected and installed in an aquarium, with the pH, ORP, and temperature probes submerged in the water.

  4. Connexió d'alimentació: Connect the power supply to the controller unit and then plug it into a standard AC outlet (AC120V or AC220V, depending on your region). The LCD screen will illuminate.
  5. Connexió Wi-Fi: Ensure your Wi-Fi network is 2.4 GHz for compatibility with the device and its mobile application. Refer to the separate Wi-Fi setup guide for detailed instructions on connecting the controller to your network and mobile app.

5. Funcionament bàsic

Once the controller is powered on and probes are submerged, it will begin displaying real-time pH, ORP, and temperature readings on its LCD screen.

  • Visualització en temps real: The LCD shows current pH, ORP, and temperature values.
  • Control de la llum de fons: The controller features backlight control for improved visibility in various lighting conditions.
  • Compensació de temperatura: The device automatically compensates for temperature variations in measurements within the range of 0~50°C.

6. Calibració

Regular calibration ensures the accuracy of your pH and ORP readings. The pH electrode requires 3-point calibration.

  1. Calibració del pH:
    • Prepare the pH buffer solutions (pH 4.0, pH 6.86, pH 9.18) using the provided powders and distilled water.
    • Press the "CAL" button next to the pH/TEMP display on the controller.Close-up of the controller showing the calibration button

      Aquesta imatge ofereix un primer pla view of the controller's display, highlighting the "CAL" button used for calibration.

    • Follow the on-screen prompts or refer to the detailed calibration steps in the separate English Instruction Manual for precise instructions on calibrating with the three buffer solutions.
  2. ORP Calibration:
    • Prepare the 256 mV ORP buffer solution.
    • Refer to the separate English Instruction Manual for specific ORP calibration procedures.

7. Mobile Application Monitoring

The controller supports remote monitoring via a dedicated mobile application, compatible with both iOS and Android devices.

  1. Instal·lació de l'aplicació: Download and install the "WiFi Online Control Monitor" app from your device's app store.
  2. Vinculació de dispositius: Follow the in-app instructions to pair your controller with the mobile application. (Note: Wi-Fi must be 2.4 GHz).
  3. Dades en temps real: View current pH, ORP, and temperature data remotely from your smartphone.Mobile application interface showing real-time pH and ORP data

    This image shows a smartphone screen displaying the mobile application interface, which provides real-time monitoring of pH, ORP, and temperature data.

  4. Dades històriques: Access and analyze historical data curves for pH and ORP over the last 30 days.
  5. Configuració d'alarma: Set custom upper and lower alarm limits for pH and ORP directly within the app. Receive push notifications on your smartphone if measurements fall outside these set limits.

8. Output Relay Control

The controller features output power relays that allow you to connect and control external devices based on your set pH or ORP parameters.

  1. Dispositius de connexió: Plug your external device (e.g., CO2 regulator, ozonizer, dosing pump) into the corresponding pH or ORP output socket on the power outlet module.
  2. Setting Control Points: Use the mobile application to define your desired pH or ORP set points.
  3. Control automatitzat: The output relay will activate (turn on your connected device) when the measured pH or ORP value goes above or below your selected set point, helping to maintain optimal water conditions automatically.Diagram showing the controller connected to external devices like CO2 reactor and O3 generator

    This diagram illustrates how the pH-ORP controller integrates with an aquarium system, showing connections to a CO2 reactor, solenoid valve, and O3 generator via the control output and power outlet.

9. Manteniment

Proper maintenance ensures the longevity and accuracy of your controller and probes.

  • Neteja d'elèctrodes: Regularly clean the pH and ORP electrodes according to their specific cleaning instructions to prevent buildup and ensure accurate readings.
  • Substitució d'elèctrodes: The high-precision electrodes are replaceable. If readings become unstable or inaccurate despite calibration, consider replacing the pH or ORP probe. Ensure replacement probes use standard BNC connectors.
  • Protecció de fusibles: The power outlet module includes a fuse for protection. If the unit loses power unexpectedly, check and replace the fuse if necessary.

10. Especificacions

ParàmetreValor
Rang de mesura del pH0.00 ~ 14.00 pH
ORP Measurement Range-2000mv ~ 2000mv
Interval de mesura de temperatura0 ~ 50 °C (32 ~ 122 °F)
Resolució de pH0.01 pH
Resolució ORP1 mv
Resolució de temperatura0.1 °C (0.2 °F)
Precisió del pH± 0.1 pH
Precisió de l'ORP± 5 mv
Precisió de la temperatura± 1.0 °C
Alarm Setting Range (pH)0.00 ~ 14.00 pH
Alarm Setting Range (ORP)-2000mv ~ 2000mv
Font d'alimentacióCA 120V o CA 220V
Compensació de temperatura0 ~ 50 °C
Temperatura de funcionament0 ~ 50 °C
Dimensions del controlador160 x 106 x 40 mm (6.29 x 4.17 x 1.57 polzades)
Power Outlet Module Dimensions130 x 65 x 55 mm (5.11 x 2.55 x 2.16 polzades)
PesAprox. 360 g
Requisit de Wi-Fi2.4 GHz
Número de modelPHC-342_EU
FabricantGain Express Holdings Ltd.
País d'origenXina
Dimensions of the controller and power outlet module

This image provides detailed dimensions of both the main controller unit and the separate power outlet module, indicating their length, width, and height in millimeters and inches.

11. Solució De Problemes

If you encounter any issues with your controller, please consider the following:

  • Sense energia: Ensure the power supply is correctly connected and the outlet is functional. Check the fuse in the power outlet module.
  • Lectures inexactes: Perform a calibration for pH and ORP. Ensure probes are clean and properly submerged. If issues persist, consider replacing the probes.
  • Problemes de connectivitat Wi-Fi: Verify your Wi-Fi network is 2.4 GHz. Ensure the controller is within range of your router. Re-pair the device with the mobile application if necessary.
  • L'aplicació no mostra dades: Check your internet connection and ensure the controller is successfully connected to Wi-Fi.

For further assistance, please refer to the full English Instruction Manual or contact customer support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.