KKnoon ET618

KKnoon TOOLTOP ET618 Handheld Portable Cable Tester User Manual

Model: ET618

1. Introducció

The KKnoon TOOLTOP ET618 is a versatile handheld portable cable tester designed for network and electrical professionals. It integrates multiple functions including cable tracing, cable length measurement, Power over Ethernet (PoE) testing, and a full-featured digital multimeter. This manual provides detailed instructions for the safe and effective use of your ET618 device.

KKnoon TOOLTOP ET618 Handheld Portable Cable Tester main unit and receiver

Figure 1: KKnoon TOOLTOP ET618 Handheld Portable Cable Tester (Main Unit and Receiver)

2. Informació de seguretat

Si us plau, llegiu i comprengui tots els avisos de seguretat i les instruccions d'ús abans d'utilitzar aquest producte. Si no segueix aquestes instruccions, pot provocar descàrregues elèctriques, incendis o lesions greus.

  • No utilitzeu el dispositiu si sembla que està danyat o no funciona correctament.
  • Always ensure the device is powered off before connecting or disconnecting cables.
  • No exposeu el dispositiu a la humitat ni a temperatures extremes.
  • Use only the specified charging cable and accessories.
  • Do not attempt to open or repair the device; refer all servicing to qualified personnel.
  • Be cautious when working with live circuits, especially during multimeter functions.

3. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:

  • 1 x ET618 Host (Main Unit)
  • 1 x receptor
  • 1 x Manual d'usuari (aquest document)
  • 1 x Clip Line
  • 1 x Cable de xarxa
  • 1 x Recharging Line (USB cable)
  • 1 x bossa d'emmagatzematge
  • 1 x Temperature Probes
  • 1 x Multimeter Probes

4. Producte acabatview

The ET618 combines a cable tester and a digital multimeter into one compact device. It features an LCD display for clear readings and a built-in flashlight for use in low-light conditions.

KKnoon TOOLTOP ET618 Main Unit and Receiver with Dual Flashlight feature

Figure 2: ET618 Main Unit and Receiver with Dual Flashlight

Característiques principals:

  • Traçat de cables: Quickly locate target cables in bundles.
  • Cable Length Test: Measure the length of various metal cables up to 500 meters.
  • Prova PoE: Check cable mapping polarity and voltage of PoE network switches.
  • Funcions del multímetre: Measure DC/AC voltage, DC/AC current, resistance, continuity, diode, and temperature.
  • Pantalla LCD: Large screen for clear data visualization.
  • Llanterna: Integrated light for improved visibility in dark environments.
  • Sensibilitat ajustable: Digital tracing sensitivity can be adjusted.
Comparison between ET616 and ET618 models, highlighting ET618's multimeter and longer length measurement

Figure 3: Product Differentiation (ET616 vs. ET618)

The ET618 model includes all features of the ET616, plus a comprehensive multimeter function and an extended cable length measurement range of up to 500 meters.

5. Configuració

5.1 Càrrega de la bateria

The ET618 main unit is powered by a rechargeable lithium battery. Before first use, fully charge the device.

  1. Connect the provided recharging line (USB cable) to the charging port on the ET618 main unit.
  2. Connecteu l'altre extrem del cable USB a un adaptador de corrent USB estàndard (no inclòs) o a un port USB de l'ordinador.
  3. The charging indicator on the device will show the charging status. Once fully charged, disconnect the cable.
ET618 main unit showing charging port and battery icon on display

Figure 4: Charging the ET618 Lithium Battery

5.2 Engegada/apagada

Press and hold the power button on the main unit to turn the device on or off. The LCD display will illuminate upon power-on.

6. Instruccions de funcionament

6.1 Cable Tracing Function

This function helps locate a specific cable among many, useful for telephone systems, computer networks, and BNC cables.

  1. Connect the cable to be traced to the appropriate port on the ET618 main unit (e.g., RJ45 for network cables).
  2. Select the "Trace" mode on the main unit.
  3. Use the receiver to scan the cables. The receiver will emit an audible tone or visual indication when it detects the signal from the target cable.
  4. Adjust the sensitivity on the receiver for precise tracing.

6.2 Prova de longitud de cable

Measure the length of various metal cables with at least two cores, including network cables, telephone lines, and BNC cables.

  1. Ensure the cable is disconnected from any active network or power source.
  2. Connect one end of the cable to the main unit's appropriate port.
  3. Select the "Length" test mode. The device will display the measured cable length on the LCD.

6.3 Prova POE

Test Power over Ethernet (PoE) network switches to check cable mapping polarity and voltage.

  1. Connect the network cable from the PoE switch to the main unit's RJ45 port.
  2. Select the "POE" test mode.
  3. The LCD will display information regarding PoE voltage and cable mapping.

6.4 Multimeter Function (ET618 Only)

The ET618 includes a full-featured multimeter for various electrical measurements. Use the provided multimeter probes for these tests.

ET618 Multimeter functions: DC Voltage, AC Voltage, Resistance, Diode

Figure 5: ET618 Multimeter Functions in Use

  • DC Voltage Mesura: Connect probes to the circuit, select DCV mode.
  • Vol. ACtage Mesura: Connect probes to the circuit, select ACV mode.
  • Mesura de corrent DC: Connect probes in series with the circuit, select DCA mode.
  • Mesura de corrent CA: Connect probes in series with the circuit, select ACA mode.
  • Mesura de la resistència: Connect probes across the component, select Ω mode.
  • Prova de continuïtat: Connect probes across the circuit; a beep indicates continuity.
  • Prova de díode: Connect probes across the diode; the forward voltagEs mostrarà una gota.
  • Mesura de la temperatura: Connect the temperature probe to the device and place the sensor at the measurement point.

Always ensure the correct function is selected and probes are connected properly to avoid damage to the device or circuit.

6.5 Ús de la llanterna

The ET618 main unit and receiver are equipped with flashlights. Press the dedicated flashlight button (if available) or refer to the device interface for activation in low-light conditions.

7. Manteniment

7.1 Neteja

Netegeu el dispositiu amb un drap suau i sec. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que no entrin líquids al dispositiu.

7.2 Cura de la bateria

Per allargar la durada de la bateria, eviteu descarregar-la completament amb freqüència. Si guardeu el dispositiu durant un període prolongat, carregueu-lo aproximadament al 50% i torneu-lo a carregar cada pocs mesos.

8. Solució De Problemes

  • El dispositiu no s'encén: Ensure the battery is charged. Connect the recharging line and try again.
  • Lectures inexactes: Check cable connections. Ensure the correct mode is selected for the measurement. For multimeter functions, verify probe connections and component integrity.
  • No signal during cable tracing: Ensure the main unit is in trace mode and the cable is properly connected. Adjust receiver sensitivity.
  • LCD display is dim: Pot ser que la bateria estigui baixa. Torneu a carregar el dispositiu.

9. Especificacions

The following table outlines the technical specifications for the ET618 model:

Technical specifications table comparing ET616 and ET618 features and ranges

Figura 6: Especificacions tècniques a continuacióview

CaracterísticaET618 Specification
Traçat analògic
Continuïtat
Seguiment del commutador (amb PoE)Per funció de multímetre
Mapatge de cables
Els indicadors de l'interruptor parpellegen
Seguiment digital gratuït sorollósDigital / Vibració
Voltage ProvesPer funció de multímetre
PoE voltage MesuramentVoltage / Polaritat
Mapatge d'identificació remotaOpcional
Gràfic de barres analògic
Main Body Flashlight
Multimeter Input Jack Indicator
Pantalla LCD
Llanterna blanca
Analogue Tracing Sound Adjustable
Indicador de bateria baixa
White Backlight
Indicador d'estalvi energètic
3km Analogue Tracing Signal Selectable
Multimeter Functions (ET618 Only)
DC Voltage400mV~1000V ±(0.8%+3)
Vol. ACtage4V~400V ±(1.5%+5)
Corrent DC1.0 A ~ 10.0 A ± (1.2% + 4)
Corrent alterna1.0 A ~ 10.0 A ± (2.0% + 5)
Resistència200 Ω~20 MΩ ±(2%+6)
Continuïtat< 50 Ω buzzer beeps
Díode
Temperatura (tipus K)-20~1000°C / -4~1832°F ±(2.0%+15)
Mesura de la longitud del cable de xarxa500M
Mesura de la longitud del cable BNC
Prova de curtcircuit/circuit obert del cable de xarxa
Main Body PowerBateria de liti recarregable de 1250 mAh
Alimentació del receptorBateria de 9 V

10. Garantia i Suport

This product comes with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official KKnoon weblloc.

© 2024 KKnoon. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.