1. Producte acabatview
The SCHMERSAL AZ 17-02ZRI-ST B6L is a safety switch with a separate actuator, designed for industrial applications requiring reliable position monitoring and safety interlocking. It features a compact thermoplastic enclosure and is engineered for long life and high contact reliability, even with low voltages and currents. This switch is particularly suitable for installations with very small actuating radii.

Figure 1: SCHMERSAL AZ 17-02ZRI-ST B6L Safety Switch with separate actuator. This image shows the SCHMERSAL AZ 17-02ZRI-ST B6L safety switch, highlighting its compact design and the separate actuator component. The main body of the switch is black, with the metallic actuator positioned above it, ready for installation.
2. Característiques clau
- Connector: M12 x 1, 4-pole, left-hand model.
- Designed for very small actuating radii, in line with or at 90° to the plane of the actuator.
- Thermoplastic enclosure for durability.
- Double-insulated for enhanced safety.
- Long operational life.
- Compact dimensions: 30 mm x 60 mm x 30 mm.
- Individual coding with "High" level according to ISO 14119.
- High level of contact reliability, even with low voltages i corrents.
- Insensitive to soiling.
- Includes slot sealing plug.
- Features 8 actuating planes.
- Standards Compliance: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1.
- Working Principle: Electromechanical.
- Number of Actuating Directions: 2.
- Number of Safety Contacts: 2.
- Number of Cable Glands: 1.
3. Configuració i instal·lació
Proper installation is crucial for the safe and reliable operation of the AZ 17-02ZRI-ST B6L safety switch. Refer to the detailed technical drawings and local safety regulations for precise mounting instructions.
3.1 Consideracions de muntatge
- The switch is designed for very small actuating radii. Ensure the actuator aligns correctly with the switch body.
- It can be mounted in line with or at 90° to the plane of the actuator. Choose the orientation that best suits your application and ensures proper engagement.
- Secure the switch body and the separate actuator firmly to prevent movement during operation.
3.2 Connexió elèctrica
- The switch utilizes an M12 x 1, 4-pole connector. Ensure proper wiring according to the provided electrical diagrams (not included in this general manual, refer to product datasheet).
- Comproveu que el vol operatiutage and current ratings of your system are compatible with the switch's specifications.
- Ensure all connections are secure and protected from environmental factors. The slot sealing plug should be used to maintain the enclosure's integrity.

Figure 2: Compact view of the SCHMERSAL AZ 17-02ZRI-ST B6L Safety Switch. A more compact view of the SCHMERSAL AZ 17-02ZRI-ST B6L safety switch, illustrating its overall dimensions and the integrated connector at the base. This view emphasizes the robust thermoplastic enclosure.
4. Instruccions de funcionament
The AZ 17-02ZRI-ST B6L operates on an electromechanical principle, functioning as a Normally Closed (NC) contact type. Its primary role is to ensure safety by monitoring the position of guards or doors.
4.1 Funcionament bàsic
- When the separate actuator is engaged with the switch body, the safety contacts are closed, allowing the machine or process to operate.
- When the actuator is disengaged (e.g., a guard is opened), the safety contacts open, interrupting the safety circuit and stopping the machine.
- The switch supports 2 actuating directions and features 8 actuating planes, offering flexibility in installation and operation.
4.2 Característiques de seguretat
- Individual Coding: The switch offers individual coding with a "High" level according to ISO 14119, enhancing tamper protecció.
- Contact Reliability: Designed for high contact reliability even with low voltages and currents, ensuring consistent performance in various electrical environments.
- Insensitivity to Soiling: The design minimizes the impact of dust and dirt, contributing to reliable operation in industrial settings.
5. Manteniment i cura
The SCHMERSAL AZ 17-02ZRI-ST B6L safety switch is designed for long life and minimal maintenance. However, periodic checks are recommended to ensure continued optimal performance and safety.
- Neteja: Periodically clean the switch body and actuator to remove any accumulated dust or debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Inspecció: Regularly inspect the switch and its wiring for any signs of physical damage, wear, or loose connections. Ensure the slot sealing plug is intact.
- Prova de funcionalitat: Perform routine functional tests to confirm that the safety contacts open and close correctly when the actuator is engaged and disengaged.
- Protecció del medi ambient: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats per evitar un desgast prematur.
6. Solució De Problemes
This section provides general guidance for common issues. For complex problems or if the issue persists, contact qualified technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| Switch not activating/deactivating | Actuator misalignment, damaged wiring, faulty connection, internal fault. | Check actuator alignment. Inspect wiring for damage. Verify M12 connector is secure. Test continuity of contacts. If problem persists, replace switch. |
| Funcionament intermitent | Loose connection, excessive vibration, contamination affecting contacts. | Tighten connections. Reduce vibration if possible. Clean switch and actuator. |
| Physical damage to enclosure | Impact, chemical exposure. | Replace the switch immediately to maintain safety integrity. |
7. Especificacions tècniques
| Especificació | Valor |
|---|---|
| Número de model | AZ 17-02ZRI-ST B6L |
| Fabricant | SCHMERSAL |
| Mode d'operació | ON-OFF |
| Valoració actual | 20531 Amps (Note: This value seems unusually high for a safety switch. Please verify with official product datasheet.) |
| Vol. Operatiutage | 200 Volts |
| Tipus de contacte | Normalment tancat |
| Tipus de connector | Plug In (M12 x 1, 4-pole) |
| Tipus d'actuador | Separate Actuator (Push Button mechanism) |
| Nombre de llocs | 2 |
| Protocol de connectivitat | Wi-Fi (Note: This seems incorrect for a safety switch. Please verify with official product datasheet.) |
| Quantitat neta | 1.0 comptes |
| País d'origen | Alemanya |
| Normes | EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1 |
| Coding Level | High (according to EN ISO 14119) |
| Principi de funcionament | Electromecànica |
| Increased Latching Force | Sí |
| Number of Actuating Directions | 2 |
| Number of Safety Contacts | 2 |
| Number of Cable Glands | 1 |
Note: Some specifications like "Current Rating" and "Connectivity Protocol" appear to be unusually high or incorrect for this type of industrial safety switch based on common industry knowledge. Always refer to the official SCHMERSAL product datasheet for the most accurate and up-to-date technical specifications.
8. Garantia i Suport
Specific warranty details for the SCHMERSAL AZ 17-02ZRI-ST B6L are not provided within this manual. Please refer to your purchase documentation or contact your supplier for warranty information.
8.1 Contacte del fabricant
For technical support, product inquiries, or service, please contact the manufacturer:
SCHMERSAL India Pvt. Ltd.Plot No - G-7/1, Ranjangaon MIDC,
Tal. - Shirur, Dist.- Pune 412 220
Índia
When contacting support, please have your product model number (AZ 17-02ZRI-ST B6L) and any relevant purchase details ready.