RWRAPS TM612
RWRAPS TM612 Programmable Timer Switch User Manual
Model: TM612 | Brand: RWRAPS
1. Introducció
The RWRAPS TM612 is a high-accuracy, programmable 24-hour time clock designed for automatic control of various electrical equipment. Featuring a large display and two relay outputs, this timer switch allows for precise scheduling with up to 44 ON/OFF programs per day or week. Its robust design includes a long-life silicone button and a high-power relay, ensuring reliable operation for extended periods. The device also incorporates a clock correction function and a keyboard lock to prevent unintended adjustments.
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your TM612 timer switch.
2. Característiques clau
- Alta precisió: Time error less than 1 second per day, ensuring precise timing.
- Horaris programables: Supports up to 44 ON/OFF programs daily or weekly for flexible control.
- Dual Relay Outputs: Equipped with two independent relay outputs (2NO 2NC) for versatile applications.
- Pantalla digital gran: Clear and easy-to-read big display for monitoring time and program status.
- Clock Correction/Calibration: Functionality to maintain accurate timekeeping.
- Bloqueig del teclat: Evita canvis accidentals en la configuració programada.
- Construcció duradora: Features long-life silicone buttons and a high-power relay for extended service life.
- Còpia de seguretat de la bateria: Built-in 3V rechargeable battery provides up to 60 days of blackout memory.
- Aplicació àmplia: Suitable for automatic control of street lights, neon lights, production equipment, radio and television, and other electrical appliances.
3. Configuració i instal·lació
Informació important de seguretat: Before proceeding with installation, ensure that the main power supply is disconnected to prevent electrical shock. Installation should only be performed by a qualified electrician or a knowledgeable individual familiar with electrical wiring.
3.1 Esquema de cablejat
The TM612 timer switch features 6 pins for connection. Refer to the diagram below for proper wiring. The device operates on a 220-250 VAC power supply.

Figura 1: Davant view of the RWRAPS TM612 timer switch. This image displays the digital screen, control buttons (Menu, Res, directional arrows, OK), and the terminal block connections at the top and bottom for power input and relay outputs. The model number "TM-612 top" is visible on the side.
- Entrada d'alimentació (L, N): Connect the live (L) and neutral (N) wires from your 220-250 VAC power source to the corresponding terminals.
- Relay Outputs (C1, 1, 2, C2, 4, 5): The TM612 has two independent relay outputs. Each relay has a common (C), normally open (NO), and normally closed (NC) contact.
- Relleu 1: C1 (Common), 1 (Normally Open), 2 (Normally Closed)
- Relleu 2: C2 (Common), 4 (Normally Open), 5 (Normally Closed)
3.2 Engegada inicial
En el moment de l'engegada inicial o després d'una apagada prolongadatage, the display may be blank. The internal rechargeable battery will charge automatically. Allow a few minutes for the display to activate. If the display remains blank, press the "Res" button to reset the device.

Figura 2: The TM612 timer switch displayed alongside its product packaging. This image displays the digital screen, control buttons, and terminal block connections, indicating its compact size and design.
4. Instruccions de funcionament
4.1 Configuració de l'hora i el dia actuals
- Premeu el botó "Menu" botó per entrar al menú principal.
- Utilitza el "+" or "-" buttons to navigate to the "Time" setting.
- Premeu "D'acord" per seleccionar.
- El dígit de l'hora parpellejarà. Feu servir "+" or "-" per ajustar l'hora. Premeu "D'acord" to confirm and move to minutes.
- Adjust minutes and then the day of the week (1=Monday, 7=Sunday) using the same method.
- Premeu "Menu" per sortir i desar la configuració.
4.2 Programació d'horaris d'encesa/apagada
The TM612 supports up to 44 ON/OFF programs. Each program consists of an ON time and an OFF time for a specific day or group of days.
- Premeu el botó "Menu" botó.
- Navigate to "Program" using "+" or "-". Premeu "D'acord".
- The display will show "1 ON". This is your first ON program.
- Ús "+" or "-" to set the desired ON hour, then press "D'acord". Repeat for minutes.
- Next, select the day(s) for this program. You can choose:
- Specific day (e.g., Mon, Tue)
- Dies laborables (de dilluns a divendres)
- Weekends (Sat-Sun)
- Every day (Mon-Sun)
- Custom combinations
- After setting the ON time and day(s), the display will show "1 OFF". Set the desired OFF hour and minutes using the same method.
- Premeu "D'acord" to confirm the OFF time.
- The display will now show "2 ON", ready for the next program. Repeat steps 4-7 for additional programs.
- To exit programming mode and save, press "Menu".
Nota: If you do not set an OFF time for an ON program, the device will remain ON until the next programmed OFF time or until manually switched.
4.3 Anulació manual
The TM612 allows for manual override of the current ON/OFF state without affecting programmed schedules. This is typically done via a dedicated button or a combination of buttons (e.g., pressing "OK" outside of menu mode).
Look for a button labeled "Manual" or "Mode" or try pressing the "OK" button when the device is displaying the current time. Each press will cycle through states like ON, OFF, AUTO ON, AUTO OFF.

Figura 3: Side profile of the TM612 timer switch. This view highlights the compact design and the integrated clips for easy mounting on a DIN rail, common in electrical enclosures.
5. Manteniment
- Neteja: Use a soft, dry cloth to clean the exterior of the timer switch. Do not use abrasive cleaners, solvents, or spray directly onto the device.
- Bateria: The internal rechargeable battery is designed for long life and typically does not require replacement. Ensure the device is regularly connected to power to keep the battery charged.
- Medi ambient: Operate the device within its specified temperature range (-10°C to +50°C) and avoid environments with excessive dust, moisture, or corrosive gases.
- Inspecció: Periodically inspect the wiring connections to ensure they are secure and free from corrosion.

Figura 4: Darrera i inferior view of the TM612 timer switch. This perspective shows the back casing, ventilation slots, and the lower set of wiring terminals, providing a comprehensive view of its physical structure.
6. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla està en blanc. | Sense subministrament d'alimentació; bateria interna descarregada. | Check power connections. Allow device to charge for a few minutes. Press the "Res" Botó (Reiniciar). |
| Programs not executing. | Incorrect time/day setting; program not saved; manual override active; wiring issue. | Verify current time and day. Re-enter and save programs. Check if the device is in "AUTO" mode. Inspect wiring connections. |
| El dispositiu no respon a les pulsacions de botons. | Keyboard lock active; internal malfunction. | Check for keyboard lock (refer to manual for specific unlock procedure, usually a long press or combination). Try pressing the "Res" button. If issue persists, contact support. |
| Time drifts significantly. | Environmental factors; internal clock issue. | Ensure device is within operating temperature range. The device has a clock correction function; if drift is excessive, contact support. |
7. Especificacions tècniques
| Paràmetre | Valor |
|---|---|
| Model | TM612 |
| Interval de temperatura | -10 °C a +50 °C |
| Font d'alimentació | 220-250 VAC |
| Consum d'energia | 4.5VA (MAX) |
| Contacte de commutació | 2 changeover switches (2NO 2NC) |
| Programes | 44 ON/OFF per day or week |
| Histèresi | 2 sec/day (at 25°C) |
| Interval mínim | 1 minut |
| Capacitat | 16A 250V AC |
| Memòria de l'apagada | 60 days (with fully charged internal battery) |
| Interval del temporitzador | 1 minut a 168 hores |
| Recarrega la bateria | 3 V |
| Error mitjà | ±1 second / 24 hours (at 25°C) |
| Pes | 0.175 kg (6.2 unces) |
| Material | Silicone (for buttons) |

Figura 5: A comparative view of multiple RWRAPS timer switches, including the TM612. This image illustrates the consistent design language across the product line and their compact form factor suitable for various installations.
8. Garantia i Suport
For warranty information, technical support, or service inquiries regarding your RWRAPS TM612 Programmable Timer Switch, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase for warranty claims.
For the most up-to-date support resources, visit the official RWRAPS weblloc web o consulteu la informació de contacte que s'inclou amb l'embalatge del producte.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.