WASSERMANN 1/2SEP167-SJES

Manual d'instruccions de la bomba submergible d'aigües residuals WASSERMANN de 1/2 HP

Model: 1/2SEP167-SJES

Brand: WASSERMANN

1. Producte acabatview

The WASSERMANN 1/2 HP Submersible Sewage Pump is engineered for efficient and reliable removal of sewage and effluent. Its robust cast iron construction and automatic float switch ensure dependable operation for various demanding drainage tasks, including basement drainage, sump basins, and sewage wells.

WASSERMANN 1/2 HP Submersible Sewage Pump

Figure 1: WASSERMANN 1/2 HP Submersible Sewage Pump with float switch.

2. Característiques clau

  • Alt rendiment: 1/2 HP oil-filled split capacitor motor with a maximum flow rate of 5300 GPH and a maximum head of 23 feet.
  • Automatic/Manual Control: Equipped with separate plugs for automatic (float switch controlled) and manual operation.
  • Construcció duradora: Rugged cast iron casing ensures longevity and resistance to harsh environments.
  • Clog-Resistant Design: Features a reinforced engineered non-clogging vortex impeller and a 2-inch NPT discharge, capable of passing 2-inch diameter solids.
  • Protecció contra el sobreescalfament: Built-in protection to prevent motor damage from overheating.
  • Cable llarg: Comes with a 10-foot UL power cable for convenient placement.
Key features of WASSERMANN sewage pump including auto on/off, cast iron material, and non-clogging impeller.

Figure 2: Visual representation of key features like automatic operation, cast iron material, and clog-resistant impeller.

WASSERMANN pump in water showing 1/2 HP, 5300 GPH max flow, 21 ft max head, and 2 inch NPT discharge.

Figure 3: Pump operating in water, highlighting its 1/2 HP power, 5300 GPH maximum flow, 21 ft maximum head, and 2-inch NPT discharge.

3. Informació de seguretat

Please read and understand all safety warnings before operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Always disconnect power before servicing or moving the pump.
  • Do not lift the pump by its power cord or float switch cable. Always use the handle or a sturdy rope attached to the handle.
  • Ensure the pump is fully immersed in water when operating to prevent overheating.
  • This sewage pump is designed for water only. Do not use it for flammable, explosive, or corrosive liquids such as oil, gasoline, kerosene, or ethanol.
  • Do not override the float switch to force the pump to work in low water levels, as this can damage the motor and shaft seal.
  • When a check valve is used, drill a relief hole (1/8" or 3/16" in diameter) in the discharge pipe between the pump and the check valve to prevent airlock.
Safety warnings for WASSERMANN pump, including proper lifting and liquid types.

Figure 4: Important safety guidelines for pump operation, emphasizing proper immersion and handling.

4. Configuració i instal·lació

Installing your WASSERMANN sewage pump is straightforward. Follow these steps for proper setup:

  1. Prepare the Discharge Pipe: Connect the PVC pipe to the pump's 2-inch NPT discharge outlet using appropriate glue and Teflon tape for a secure, watertight seal.
  2. Drill Airlock Relief Hole: If using a check valve, drill a 3/16-inch diameter relief hole in the discharge pipe between the pump and the check valve. This prevents air from becoming trapped, which can cause the pump to run dry.
  3. Posició de la bomba: Place the pump in the sump basin or sewage well, ensuring it is on a stable, level surface. The float switch should have free movement and not be obstructed by the basin parets o altres objectes.
  4. Connectar l'alimentació:
    • Funcionament automàtic: Connect the pump's power plug to the float switch's plug, then plug the float switch's plug into a grounded 115V electrical outlet. The pump will automatically start when the water level reaches approximately 17 inches and stop when it drops to about 7 inches.
    • Funcionament manual: For continuous operation, bypass the float switch by plugging the pump's power plug directly into a grounded 115V electrical outlet. The pump will run continuously as long as it is powered.
Close-up of pump components: 2 inch NPT discharge, adjustable float switch, auto plug, and manual plug.

Figure 5: Key components for installation, including discharge port and power plugs.

Diagram showing pump installation in a sump basin with ON and OFF water levels.

Figure 6: Typical installation in a sump basin, illustrating automatic water level activation (ON: 17", OFF: 7").

Video 1: Demonstrates the installation process and operation of the WASSERMANN submersible sewage pump, including connecting PVC pipes, drilling the airlock hole, and plugging in for automatic and manual modes.

5. Instruccions de funcionament

The WASSERMANN sewage pump offers both automatic and manual operating modes:

  • Mode automàtic: When the pump is connected via its float switch, it will automatically activate when the water level rises to approximately 17 inches and deactivate when the water level falls to about 7 inches. This mode is ideal for continuous, unattended operation in sump basins or sewage wells.
  • Mode manual: If the pump's power plug is connected directly to the electrical outlet (bypassing the float switch), the pump will run continuously. This mode is suitable for situations requiring constant pumping or for completely draining a basin. Ensure the pump remains fully submerged to prevent damage during manual operation.

The pump is designed for use in various applications:

Image showing a flooded basement, indicating a suitable application for the pump.

Figura 7: Aplicació example: Basement drainage.

Image showing a sump basin, indicating a suitable application for the pump.

Figura 8: Aplicació example: Sump basin drenatge.

Image showing a sewage well, indicating a suitable application for the pump.

Figura 9: Aplicació example: Sewage well drainage.

6. Manteniment

Regular maintenance ensures the longevity and optimal performance of your WASSERMANN sewage pump. Always disconnect the pump from power before performing any maintenance.

  • Inspeccionar regularment: Periodically check the pump, power cord, and float switch for any signs of damage, wear, or corrosion.
  • Impulsor net: If the pump's performance decreases, the impeller may be clogged. Disconnect power, remove the pump, and clear any debris from the impeller area.
  • Check Sump Basin: Keep the sump basin free of excessive debris that could obstruct the pump or float switch.
  • Test Float Switch: Occasionally test the float switch by manually lifting it to ensure the pump activates and deactivates correctly.

7. Solució De Problemes

Si la bomba no funciona com s'espera, consulteu els problemes i solucions habituals següents:

Problema Causa possible Solució
La bomba no arrenca. No power; Float switch stuck; Clogged impeller. Check power supply/breaker; Ensure float switch moves freely; Clear debris from impeller.
La bomba funciona contínuament. Float switch stuck in "ON" position; Pump plugged directly into outlet (manual mode). Ensure float switch moves freely; If in manual mode, unplug when not needed or connect via float switch for automatic operation.
Flux d'aigua baix o nul. Clogged discharge pipe or impeller; Airlock in discharge pipe; Pump not fully submerged. Clear obstructions; Ensure airlock relief hole is present and clear; Ensure pump is fully submerged.
La bomba circula amb massa freqüència. Sump basin too small; Float switch set incorrectly. Consider a larger sump basin; Adjust float switch settings if possible (refer to installation diagram).

8. Especificacions

Especificació Valor
Poder 1 / 2 HP
Ampere 7A
Voltage / Freqüència 115V/60Hz
Caudal màxim 5300 GPH (88.3 galons per minut)
Alçada màxima d'elevació (capçal) 23 peus
Mida de descàrrega 2" NPT
Longitud del cable d'alimentació 10 peus
Minimum Starting Water Level 17 polzades
Minimum Stopping Water Level 7 polzades
Màxima profunditat submergible 23 peus
Pes 23.1 lliures
Material Ferro colat
Dimensions del producte (L x A x A) 9.1 cm de llargada x 6.1 cm d'amplada x 15.81 cm d'alçada
Technical specifications table for WASSERMANN sewage pump, including power, voltage, flow rate, and dimensions.

Figure 10: Detailed technical specifications of the pump.

Performance curve graph for WASSERMANN sewage pump showing flow rate versus head.

Figure 11: Pump performance curve illustrating flow rate at various head heights.

9. Garantia i Suport

For warranty information, technical assistance, or any product-related inquiries, please contact WASSERMANN customer service through the retailer's platform or the official WASSERMANN website. Please have your model number (1/2SEP167-SJES) and purchase date available when contacting support.

© 2025 WASSERMANN. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.