The INFICON D-TEK Stratus is an advanced refrigerant leak detector and portable monitor designed for efficient and accurate leak detection. This device combines the precision of D-TEK Select detectors with the broad area scanning capability of a portable monitor, offering a comprehensive solution for identifying refrigerant leaks.

It features an infrared sensor, dual operating modes (Cloud Hunting and Pinpoint), and a robust design for field use. This manual provides essential information for the proper setup, operation, and maintenance of your D-TEK Stratus unit.

2. Característiques clau

  • Modes de funcionament duals: Cloud Hunting mode for locating the general area of highest concentration and Pinpoint mode for precise leak identification.
  • Advanced Infrared Sensor: Redesigned for enhanced performance and an extended lifespan of over 2,000 hours.
  • Alta sensibilitat: Detects leaks as small as 0.03 oz./year (1 g/year) without degradation over time.
  • Versatile Refrigerant Detection: Compatible with CFCs, HCFCs, HFCs, HFOs, and A2Ls. Optional sensors are available for CO2 and flammable refrigerants.
  • Field Replaceable Components: Sensor, battery, filters, and probe are easily replaceable in the field.
  • Bateria de ions de liti: Provides extended operation with quick charge capability.
  • Interfície fàcil d'utilitzar: Large, easy-to-read LCD display and intuitive controls.
  • Automatic and Manual Zero Modes: For optimal calibration in various environments.

3. Contingut del paquet

En obrir el paquet, comproveu que hi hagi tots els elements següents:

INFICON D-TEK Stratus package contents including the device, chargers, earbuds, and carry case.

Image: The INFICON D-TEK Stratus device shown with its complete set of accessories, including the main unit, various international AC wall chargers, a DC car charger, earbuds, spare filters, an extra-long probe, an infrared sensor, a lithium-ion battery, and a durable carry case.

  • D-TEK Stratus Unit
  • Infrared Sensor (pre-installed or separate)
  • Bateria de ions de liti (preinstal·lada o separada)
  • AC Wall Charger (US & International adapters)
  • Carregador de cotxes DC
  • Extra-Long Probe
  • Auriculars
  • Filtres de recanvi
  • Maleta de transport

4. Configuració

4.1 Càrrega inicial

Before first use, fully charge the lithium-ion battery. Connect the provided AC wall charger or DC car charger to the micro USB power input port on the device. The charging indicator on the display will show the charging status.

4.2 Sensor and Filter Installation

Ensure the infrared sensor and filter are correctly installed. The sensor is typically pre-installed. Filters are located at the probe tip and should be clean and free of debris for optimal performance.

INFICON D-TEK Stratus Refrigerant Leak Detector

Image: The INFICON D-TEK Stratus device, showing its main body, flexible probe, and digital display indicating a refrigerant concentration of 1345 ppm. This image highlights the device's ergonomic design and clear interface.

4.3 Dispositiu acabatview

Familiarize yourself with the device's controls and components:

INFICON D-TEK Stratus device components labeled

Imatge: Una imatge detallada view of the INFICON D-TEK Stratus, with labels pointing to key components such as the probe tip/filter, headphone jack, volume button, battery cover, eject button, micro USB power input, SENS/ZERO button, and Mode/Max button. The power button is indicated as not visible in this view.

  • Botó d'encesa: Encén/apaga el dispositiu.
  • Mode/Max Button: Toggles between Cloud Hunting and Pinpoint modes, and displays maximum readings.
  • SENS/ZERO Button: Adjusts sensitivity and performs manual zeroing.
  • Auriculars Jack: For connecting earbuds for audio alerts.
  • Botó de volum: Adjusts audio alert volume.
  • Entrada d'alimentació micro USB: Per carregar el dispositiu.
  • Botó d'expulsió: Releases the sensor module for replacement.
  • Tapa de la bateria: Provides access to the battery compartment.
  • Probe Tip/Filter: The detection point, containing a replaceable filter.

5. Instruccions de funcionament

5.1 Powering On and Initial Calibration

  1. Manteniu premut el botó d'engegada per encendre el dispositiu.
  2. Allow the device to warm up and perform its automatic zeroing process in a clean, leak-free environment. This ensures accurate readings.

5.2 Modes de funcionament

The D-TEK Stratus offers two distinct operating modes for efficient leak detection:

INFICON D-TEK Stratus Cloud Hunting and Pinpoint Modes

Image: This graphic illustrates the two primary operating modes of the INFICON D-TEK Stratus. The top section shows "Cloud Hunting Mode" with a digital display indicating 1345 ppm, used for finding areas of highest concentration. The bottom section shows "Pinpoint Mode" with a color-coded bar graph, used for precisely locating the leak source.

5.2.1 Cloud Hunting Mode

  • Use this mode to quickly scan large areas and identify the general vicinity of a refrigerant leak.
  • The display will show refrigerant concentration in parts per million (ppm).
  • Move the probe slowly through the suspected area. Higher readings indicate proximity to a leak.

5.2.2 Pinpoint Mode

  • Once the general leak area is identified using Cloud Hunting, switch to Pinpoint mode for precise leak location.
  • In this mode, the device provides a more focused indication, often with a visual bar graph or escalating audio tone, to guide you directly to the leak source.
  • Move the probe very slowly and methodically around suspected leak points.

5.3 Adjusting Sensitivity and Zeroing

  • Sensibilitat: Press the SENS/ZERO button to cycle through sensitivity levels. Adjust sensitivity based on the size of the suspected leak and environmental conditions.
  • Manual Zero: If the device is alarming in a clean environment, move the probe to an area free of refrigerants and press and hold the SENS/ZERO button to perform a manual zero.

6. Informació del sensor

The D-TEK Stratus utilizes an advanced infrared sensor for detecting a wide range of refrigerants. The sensor has an expected lifespan of over 2,000 hours.

6.1 Compatible Refrigerants

The standard infrared sensor detects:

  • CFCs (Chlorofluorocarbons)
  • HCFCs (Hydrochlorofluorocarbons)
  • HFCs (Hydrofluorocarbons)
  • HFOs (Hydrofluoroolefins)
  • A2Ls (Mildly Flammable Refrigerants)

6.2 Sensors opcionals

For detecting other gases, optional sensors are available and can be easily interchanged:

INFICON D-TEK Stratus interchangeable sensors

Image: This image displays three different sensor modules for the INFICON D-TEK Stratus. The red sensor is for CFCs, HCFCs, HFCs, HFOs, and A2Ls (included refrigerant sensor). The silver sensor is for flammable refrigerants (requires optional sensor). The green sensor is for CO2 (requires optional sensor). This illustrates the device's versatility with interchangeable sensors.

  • Sensor de CO2: Required for detecting Carbon Dioxide.
  • Flammable Refrigerants Sensor: Required for detecting flammable refrigerants.

7. Informació de la bateria

The D-TEK Stratus is powered by a rechargeable Lithium-Ion battery, providing approximately 9 hours of continuous operation on a full charge. The battery is designed for quick charging.

7.1 Càrrega

Use only the INFICON-supplied AC wall charger or DC car charger. Connect the charger to the micro USB port on the device. The battery indicator on the display will show the charging status.

7.2 Substitució de la bateria

The Lithium-Ion battery is field replaceable. Refer to the maintenance section for instructions on how to safely replace the battery.

8. Manteniment

Regular maintenance ensures the longevity and accuracy of your D-TEK Stratus.

8.1 Substitució del filtre

The probe tip contains a filter that prevents contaminants from entering the sensor. Replace the filter regularly, especially if operating in dusty or dirty environments, or if you notice a decrease in sensitivity. Spare filters are included with your unit.

  1. Gently unscrew the probe tip.
  2. Traieu el filtre antic.
  3. Inseriu un filtre nou.
  4. Screw the probe tip back on securely.

8.2 Substitució del sensor

The infrared sensor is field replaceable. When the sensor reaches the end of its lifespan (indicated by a message on the display or persistent inaccurate readings), it should be replaced.

  1. Assegureu-vos que el dispositiu estigui apagat.
  2. Locate the eject button (refer to Device Overview).
  3. Press the eject button to release the sensor module.
  4. Carefully remove the old sensor.
  5. Insert the new sensor module, ensuring it clicks into place.
  6. Power on the device and allow it to calibrate with the new sensor.

8.3 Neteja

Netegeu l'exterior del dispositiu amb un anunciamp cloth. Do not use abrasive cleaners or solvents. Ensure the probe tip and sensor area remain clean and free of obstructions.

9. Solució De Problemes

If you encounter issues with your D-TEK Stratus, consider the following common solutions:

  • El dispositiu no s'encén:
    • Assegureu-vos que la bateria estigui completament carregada.
    • Comproveu si la bateria està instal·lada correctament.
  • Inaccurate Readings or Constant Alarm:
    • Perform a manual zero in a clean air environment.
    • Check and replace the probe tip filter if it is dirty or clogged.
    • Verify the sensor is correctly installed and not at the end of its lifespan.
    • Ensure the correct sensor type is installed for the refrigerant being detected.
  • Sense detecció:
    • Increase the sensitivity setting.
    • Ensure the probe is moved slowly and methodically.
    • Check the sensor for proper installation and remaining lifespan.
    • Confirm the presence of refrigerant; test with a known leak source if possible.
  • Durada de la bateria curta:
    • Assegureu-vos que la bateria estigui completament carregada abans d'utilitzar-la.
    • Consider replacing the battery if it no longer holds a charge effectively.

For persistent issues, contact INFICON customer support.

10. Especificacions

MarcaInficon
Número de model724-202-G1
EstilMonitor
Font d'alimentacióFunciona amb bateria (ió de liti)
ColorBlanques
Dimensions del producte4 "P x 8" W x 12" H
Pes de l'article2.1 unces
Tipus d’alarmaVisual
Humitat de funcionament95% RH NC Max
Tipus de sensorinfrarojos
Vida del sensor> 2,000 hores
Sensibilitat0.03 oz./year (1 g/year)
Durada mitjana de la bateria9 hores
UPC810044830330

11. Garantia i Suport

INFICON stands behind the quality of its products.

INFICON D-TEK Stratus warranty and support information

Image: This graphic highlights INFICON's commitment to quality and customer support. It features icons and text indicating a "2 Year Replacement Warranty," "Made in the USA with US and Imported Parts," and "US Technician Support" available via email and phone.

11.1 Informació de la garantia

The INFICON D-TEK Stratus comes with a Two-Year Replacement WarrantyAquesta garantia cobreix els defectes de materials i de fabricació en condicions d'ús normal. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.

11.2 Suport tècnic

For technical assistance, troubleshooting, or warranty inquiries, please contact INFICON US Technician Support. Support is available via email and phone.

The product is proudly Fabricat als EUA with a combination of US and imported parts, reflecting a commitment to quality manufacturing.

© 2023 INFICON. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.