DATOUBOSS 10200W

DATOUBOSS 10200W Hybrid Solar Inverter 48V Instruction Manual

Model: 10200W

1. Introducció

This manual provides essential information for the installation, operation, and maintenance of your DATOUBOSS 10200W Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper use and safety. Keep this manual for future reference.

2. Instruccions de seguretat

AVÍS: Si no es segueixen aquestes instruccions de seguretat, es poden produir lesions greus o danys a l'equip.

  • The starting power of an inductive load must be at least three times the rated power of the inverter. Connecting loads with too high switching power can damage the inverter.
  • Ensure all circuits are connected correctly and install appropriate circuit breakers for each circuit to prevent overcurrent and short circuits.
  • Follow the correct ignition order during startup: First, connect the battery, then turn on the inverter, and finally connect the PV (solar panels), mains (utility grid), and load circuit breakers.
  • Follow the reverse order when shutting down the system: Disconnect load, mains, PV, then turn off the inverter, and finally disconnect the battery.
  • This inverter provides multiple protection methods including short circuit protection, over-current protection, over-voltage protecció, sota-voltage protection, overload protection, backfill protection, and over-temperature protection. However, proper installation and operation are crucial for safety.
DATOUBOSS Inverter Comprehensive Protection Features

Image: Comprehensive protection features of the DATOUBOSS Hybrid Solar Inverter, including short circuit, over-current, over-charge, under-voltage, sobrevoltage, backfill, over-load, and over-temperature protection.

3. Producte acabatview

The DATOUBOSS 10200W Hybrid Solar Inverter is a 48V DC to 220V/230V AC pure sine wave inverter with an integrated 160A MPPT solar charge controller. It is designed to provide reliable power for various home or office appliances and supports both lead-acid and lithium batteries.

3.1 Característiques clau

  • Sortida d'alta potència: 10.2KW rated power, capable of powering various electrical appliances.
  • Dual Photovoltaic Input: Features two independent MPPTs with a total of 36A, allowing connection of higher power solar panels for uninterrupted power supply.
  • Dual AC Output: Provides a primary and secondary output. The secondary output remains active when the primary circuit turns off due to low battery voltage or lack of PV/grid power, similar to a super power-saving mode.
  • Versatile Charging Modes: Offers 4 configurable charging modes: Solar Priority, Solar Only, Utility Priority, and Solar Hybrid and Utilities.
  • Modes de sortida flexibles: Includes 3 output modes: Solar Priority (SUB), Utility Priority (USB), and SBU (Solar-Battery-Utility).
  • Àmplia compatibilitat: Compatible with various battery types including FLD, GEL, SLD, AGM, and Lithium.
DATOUBOSS 10200W Hybrid Solar Inverter Front View

Imatge: Frontal view of the DATOUBOSS 10200W Hybrid Solar Inverter, showcasing its compact design and integrated display.

DATOUBOSS Inverter Key Specifications Overview

Imatge: Més deview of key specifications including 150V starting voltage, 10200W AC output power, 160A MPPT solar charge controller, and 500Vdc maximum PV array open circuit voltage.

3.2 Descripció de l'aparença

The inverter features an LCD display for monitoring, status and fault indicators, charging indicators, and touch function buttons for configuration. The rear panel includes various connection ports.

DATOUBOSS Inverter Labeled Front and Back Panels

Image: Detailed appearance description showing the LCD display, indicators, touch buttons on the front, and AC input, main output, second output, PV1/PV2 inputs, battery input, and communication ports on the rear panel.

4. Configuració i instal·lació

Proper installation is critical for the safe and efficient operation of your hybrid solar inverter. Ensure all connections are secure and follow local electrical codes.

4.1 Muntatge de l'inversor

Mount the inverter in a well-ventilated area, away from direct sunlight, moisture, and flammable materials. Ensure sufficient clearance around the unit for heat dissipation.

4.2 Connexions elèctriques

Refer to the system connection diagram for detailed wiring instructions. All wiring should be performed by a qualified electrician.

  • Connexió de la bateria: Connect the 48V battery bank to the designated battery input terminals. Ensure correct polarity.
  • Connexió d'entrada FV: Connect your solar panels to the PV1 and PV2 input terminals. The inverter supports dual MPPT inputs, allowing for flexible solar array configurations. The PV operating voltage range is 90Vdc-450Vdc, with a maximum open circuit voltage de 500V DC.
  • Connexió d'entrada de CA: Connect the utility grid (mains power) to the AC input terminal.
  • Connexió de sortida de CA: Connect your household or office appliances to the main output and second output terminals.
DATOUBOSS Inverter Dual MPPT Inputs and Battery Compatibility

Image: Illustration of dual MPPT inputs for solar panels and compatibility with multiple battery types including FLD, GEL, SLD, AGM, and Lithium.

DATOUBOSS Inverter System Connection Diagram

Image: System connection diagram showing solar panels, generator, power grid, external battery packs, and home appliances connected to the DATOUBOSS Hybrid Solar Inverter.

5. Modes de funcionament

The DATOUBOSS Hybrid Solar Inverter offers flexible charging and output modes to optimize energy usage based on your preferences and available power sources.

5.1 modes de càrrega

The battery charging current can be configured via the LCD display. There are four available charging modes:

  1. Prioritat solar: Prioritizes solar power for charging the battery.
  2. Només solar: Charges the battery exclusively from solar power.
  3. Prioritat d'utilitat: Prioritizes utility grid power for charging the battery.
  4. Solar Hybrid and Utilities: Utilizes both solar and utility power for charging.

5.2 Modes de sortida

The inverter provides three output modes to manage power distribution to your loads:

  1. Solar Priority (SUB): Prioritizes solar power, then battery, then utility grid for powering loads.
  2. Utility Priority (USB): Prioritizes utility grid power, then solar, then battery for powering loads.
  3. SBU Priority (Solar-Battery-Utility): Prioritizes solar power, then battery, then utility grid for powering loads.
DATOUBOSS Inverter Charging and Discharge Modes

Image: Diagram illustrating the four charging modes (Priority of mains power supply, Solar priority, Mixed loading, Solar only) and three discharge modes (SUB Solar First, USB Utility First, SBU Priority).

6. Manteniment

Regular maintenance ensures the longevity and optimal performance of your DATOUBOSS Hybrid Solar Inverter.

  • Neteja: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation, which can hinder cooling. Use a dry, soft cloth.
  • Comprovació de connexions: Inspeccioneu anualment totes les connexions elèctriques (fotovoltaica, bateria, entrada/sortida de CA) per comprovar si estan ben ajustades i si hi ha signes de corrosió. Estrenyeu qualsevol connexió solta.
  • Control ambiental: Ensure the installation environment remains within the specified operating temperature range and free from excessive humidity or corrosive substances.
  • Actualitzacions de firmware: Comproveu el del fabricant weblloc web per a qualsevol actualització de firmware disponible per assegurar-vos que el vostre inversor tingui les darreres funcions i correccions d'errors.

7. Solució De Problemes

If you encounter issues with your inverter, refer to the following basic troubleshooting steps. For complex problems, contact customer support.

  • Sense alimentació/Pantalla apagada: Comproveu les connexions de la bateria, el volum de la bateriatage, and AC input power. Ensure the inverter's power switch is ON.
  • Alarma de sobrecàrrega: Reduce the connected load. Ensure the total load does not exceed the inverter's rated power. Remember inductive loads require higher starting power.
  • PV Input Error: Check solar panel connections, PV array voltage, and ensure no shading is affecting the panels. Verify PV operating voltage està dins de l'interval especificat.
  • Bateria baixa Voltage Alarma: Check battery charge level. Ensure solar panels are generating power or the utility grid is connected for charging.
  • Alarma de sobre temperatura: Ensure the inverter is in a well-ventilated area and its cooling fins are not obstructed. Clean any dust from the vents.

8. Especificacions

The following table details the technical specifications of the DATOUBOSS 10200W Hybrid Solar Inverter.

DATOUBOSS Inverter Detailed Specifications Label

Image: Detailed specifications label found on the inverter, including model number, power ratings, input/output voltages, and operating conditions.

CaracterísticaEspecificació
Número de model48V 10200W
Potència nominal10200 W (10.2 kW)
Entrada Voltage48V DC
Vol. De sortidatage220V/230V AC
Controlador de càrrega solar MPPT160A
Potència d’entrada màxima PV10200W
Vol d'operació fotovoltaicatage Rang90 Vdc-450 Vdc
Max PV circuit obert Voltage500V DC
Max PV Load Current160Amp
Corrent nominal de sortida44.3Amp
Eficiència de conversióFins al 99%
Dimensions del producte24.02 x 18.5 x 8.27 polzades
Pes de l'article33 lliures
Interval de temperatura de funcionament-10 a 50 ℃

9. Garantia i Suport

DATOUBOSS products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official DATOUBOSS website. For technical support, troubleshooting assistance, or spare parts, please contact DATOUBOSS customer service through the contact information provided on the product packaging or weblloc.

When contacting support, please have your product model number (48V 10200W) and serial number (if applicable) ready.

Ask a question about this manual