OLMO 18K-12K+12K

OLMO 18,000 BTU Dual Zone 12K+12K Mini Split A/C and Heater Instruction Manual

Model: 18K-12K+12K

Introducció

This manual provides essential instructions for the installation, operation, and maintenance of your OLMO 18,000 BTU Dual Zone Mini Split Air Conditioner and Heater (Model: 18K-12K+12K). Please read this manual thoroughly before using the unit to ensure proper function and safety. Retain this manual for future reference.

Informació important de seguretat

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons. This unit operates on 208-230V and requires professional installation. Do not attempt to install or repair the unit yourself.

  • Ensure the power supply matches the unit's requirements (208-230V).
  • Do not block air inlets or outlets of the indoor or outdoor units.
  • Mantenir els nens allunyats de la unitat.
  • Desconnecteu l'alimentació abans de netejar o realitzar tasques de manteniment.
  • Contact qualified service personnel for repairs.

Components del producte

The OLMO 18,000 BTU Dual Zone Mini Split system includes the following main components:

  • One (1) Outdoor Condenser Unit (18,000 BTU)
  • Two (2) Wall Mount Indoor Air Handlers (12,000 BTU each)
  • Dos (2) comandaments a distància
  • Two (2) 16ft Pre-Flared and Insulated Copper Line Sets
  • Two (2) Communication Wires
  • Two (2) 16ft Drainage Extensions with accessories
OLMO Dual Zone Mini Split System Components
Imatge: Més deview of the OLMO Dual Zone Mini Split system components, including the outdoor condenser, two indoor wall-mount units, two remote controls, and installation kits.

This image displays the complete package: the outdoor condenser, two indoor wall-mount units, two remote controls, and the necessary installation kits, including copper line sets, communication wires, and drainage extensions.

Configuració i instal·lació

Professional installation is required for this equipment. Improper installation can lead to electric shock, fire, water leakage, and other hazards. Ensure that the installation is performed by a qualified HVAC technician.

Llista de verificació prèvia a la instal·lació:

  • Verify that the power supply meets the unit's specifications (208-230V).
  • Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm all included components are present (refer to "Product Components" section).
  • Prepare necessary tools and safety equipment for installation.

Installation Kit Details:

The system includes a 16ft installation kit for each air handler, comprising:

  • 99.9% Copper (ASTM B-280) Pre-insulated (ASTM D154) UV & UV-C Protected Pre-flared Line Set
  • 4/16 AWG Connecting Cable
  • Rubberized 16' Drainage Hose
  • Bandage Tape
  • Màniga de paret
  • Neoprè
OLMO Mini Split Installation Kit
Imatge: Detallada view of the included installation kit components, such as copper line sets, drainage hose, and electrical cables.

This image illustrates the various parts of the installation kit, including the pre-flared copper line sets, communication wires, drainage hose, and other small accessories required for connecting the indoor and outdoor units.

Outdoor Condenser Placement:

The outdoor condenser unit should be placed on a stable, level surface, away from direct sunlight and obstructions that could impede airflow. Ensure sufficient clearance around the unit for proper ventilation and maintenance.

OLMO Outdoor Condenser Unit
Imatge: Primer pla view of the OLMO outdoor condenser unit, highlighting its fan and protective grille.

This image shows the outdoor condenser unit, which houses the compressor and fan. Proper placement is crucial for efficient operation and heat dissipation.

Instruccions de funcionament

Your OLMO Mini Split system can be controlled via the included remote control or through the OLMO Remote app on your smartphone using smart port adapters.

Funcions de control remot:

OLMO Mini Split Remote Control
Image: The OLMO Mini Split remote control, displaying various buttons for mode selection, temperature adjustment, fan speed, and special functions.

This image displays the remote control for the OLMO Mini Split system. Key functions include:

  • Botó d'encesa: Encén o apaga la unitat.
  • Botó de mode: Cycles through operating modes (Cool, Heat, Dry, Fan, Auto).
  • Ajust de temperatura: Up/Down arrows to set desired temperature.
  • Velocitat del ventilador: Adjusts fan intensity (Low, Medium, High, Auto).
  • Mode de repòs: Optimitza la temperatura i la velocitat del ventilador per a un son còmode.
  • Temporitzador: Sets a timer for automatic on/off operations.
  • Louver Auto Swing: Controls the vertical movement of the air louvers.
  • Mode silenciós: Redueix el soroll de funcionament.
  • Mode econòmic: Funcionament d'estalvi d'energia.

Control de l'aplicació per a telèfon intel·ligent:

The OLMO Remote app allows you to control each air handler individually from your smartphone. Smart port adapters are included for this functionality.

OLMO Smart Connect App Interface
Image: A smartphone screen displaying the OLMO Smart Connect app interface, showing temperature settings, mode selection, and other control options.

This image illustrates the user interface of the OLMO Smart Connect app on a smartphone, demonstrating how users can remotely monitor and adjust settings such as temperature, operating mode, and fan speed for their mini split units.

Modes de funcionament:

  • Mode de refrigeració: Provides cooling by removing heat from the indoor space.
  • Mode de calefacció: Provides heating, effective down to -13°F ambient temperature.
  • Mode sec (deshumidificació): Redueix la humitat a l'habitació.
  • Mode de ventilador: Fa circular l'aire sense escalfar ni refredar.
  • Mode automàtic: Automatically selects cooling or heating based on the set temperature and room temperature.

Manteniment

Regular maintenance ensures optimal performance and extends the lifespan of your OLMO Mini Split system. Always disconnect power before performing any maintenance.

Neteja del filtre d'aire:

  • The indoor unit's air filters should be cleaned every two weeks or more frequently depending on usage and air quality.
  • Obriu el panell frontal de la unitat interior i traieu els filtres.
  • Wash filters with lukewarm water and a mild detergent. Rinse thoroughly and allow to air dry completely before reinserting.
  • No utilitzeu la unitat sense filtres.

Neteja de la unitat exterior:

  • Periodically clean the outdoor unit's coils and fan blades to remove dust, leaves, and other debris.
  • Use a soft brush or vacuum cleaner. Avoid bending the coil fins.
  • Ensure the drainage outlet is clear of obstructions.

Inspecció professional:

It is recommended to have a qualified technician inspect the system annually to check refrigerant levels, electrical connections, and overall system health.

Resolució de problemes

Abans de contactar amb el servei tècnic, torneu aview els següents problemes i solucions habituals:

ProblemaCausa possibleSolució
La unitat no començaNo power; Remote control batteries low; Timer function active.Check power supply; Replace remote batteries; Deactivate timer.
Refrigeració/calefacció insuficientDirty air filters; Blocked air inlets/outlets; Incorrect temperature setting; Doors/windows open.Clean air filters; Clear obstructions; Adjust temperature; Close doors/windows.
Fuita d'aigua de la unitat interiorMànega de desguàs obstruïda; instal·lació incorrecta.Clear drain hose; Contact professional for inspection.
Soroll inusualPeces soltes; Obstrucció al ventilador; Unitat no anivellada.Inspect for loose parts; Remove obstructions; Ensure unit is level. If noise persists, contact service.

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb personal de servei qualificat.

Especificacions del producte

Below are the key specifications for the OLMO 18,000 BTU Dual Zone Mini Split A/C and Heater (Model: 18K-12K+12K).

CaracterísticaEspecificació
MarcaOLM
Número de model18K-12K+12K
Tipus de sistemaAire condicionat i calefacció mini split sense conductes de doble zona
Outdoor Condenser Capacity18,000 BTU
Indoor Air Handler Capacity (each)12,000 BTU
Voltage208-230 volts
Classificació SEER221
Heating Ambient Temperature RangeFins a -13 °F
RefrigerantR 410A
Tipus d'instal·lacióSplit System, Wall Mount
CertificacionsUL Listed, AHRI Certified, Energy Star
Dimensions del producte (unitat exterior)48 x 40 x 40 polzades (dimensions aproximades d'enviament)
Tipus de materialCoure, plàstic
OLMO Outdoor Unit Specifications Table
Image: Table detailing outdoor unit specifications for various OLMO models, including cooling/heating capacity, EER2, SEER2, HSPF2, dimensions, and refrigerant type.

This image presents a detailed table of outdoor unit specifications, including power supply, cooling and heating capacities, efficiency ratings (EER2, SEER2, HSPF2), dimensions, and refrigerant information for different OLMO outdoor models. The 18,000 BTU model (OS-MSR18-230VO) is relevant to this manual.

OLMO Indoor Unit Specifications Table
Image: Table detailing indoor unit specifications for various OLMO models, including cooling/heating capacity, power, current, airflow, noise level, and dimensions.

This image provides a comprehensive table of indoor unit specifications, covering power supply, cooling and heating capacities, output power, rated current, indoor airflow, noise levels, and net dimensions for various OLMO indoor models. The 12,000 BTU model (OS-MS12SRW-230VI) is relevant to this manual.

Garantia i Suport

OLMO provides a limited warranty for this product:

  • 5 anys de garantia limitada al compressor.
  • 2 anys de garantia limitada on parts.

For warranty claims or technical support, please contact OLMO customer service. Ensure you have your model number (18K-12K+12K) and proof of purchase available.

OLMO 5 Year Compressor and 2 Year Parts Warranty
Image: Graphic indicating a 5-year limited warranty on the compressor and a 2-year limited warranty on parts for OLMO products.

This image visually confirms the warranty terms: a 5-year limited warranty for the compressor and a 2-year limited warranty for other parts, providing assurance of product quality and support.

© 2024 OLMO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.