BONKZEBU BONKZEBUny28bhqrxa-11

BONKZEBU Submersible Pump Control Box (US Plug 110V) Instruction Manual

1. Producte acabatview

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your BONKZEBU Submersible Pump Control Box. This control box is designed to connect and manage deep well submersible pumps, ensuring reliable water supply and drainage.

BONKZEBU Submersible Pump Control Box

Imatge 1.1: Frontal view of the BONKZEBU Submersible Pump Control Box.

Característiques principals:

  • Carcassa d'ABS resistent: Constructed from high-quality ABS material, offering impact resistance, scratch resistance, and environmental friendliness.
  • Control box highlighting ABS shell construction

    Image 1.2: The control box features a durable ABS shell.

  • Integrated Thermal Protection: Features a built-in thermal protection circuit breaker for enhanced safety and longevity of the pump system.
  • Construcció robusta: Made with excellent, strong, and thick materials, ensuring a smooth surface and extended service life.
  • Fàcil operació: Designed for straightforward connection and control of deep well submersible pumps.
  • Corrosion-Resistant Components: Utilizes stainless steel materials for erosion resistance, good mechanical properties, and high strength.

2. Informació de seguretat

ADVERTIMENT: Before performing any installation, maintenance, or troubleshooting, always ensure the power supply to the control box is completely disconnected. Failure to do so can result in electric shock, serious injury, or death.

Warning label on the control box indicating to disconnect power

Image 2.1: Warning label indicating to disconnect power before removing the cover.

  • Llegiu atentament totes les instruccions abans de la instal·lació i el funcionament.
  • Assegureu-vos que totes les connexions elèctriques les faci un electricista qualificat i que compleixin les normes elèctriques locals.
  • No feu funcionar la caixa de control si està danyada o sembla que no funciona correctament.
  • Keep children and unauthorized personnel away from the control box during operation.
  • Protect the control box from moisture and direct exposure to weather unless specifically rated for outdoor use.

3. Configuració i instal·lació

The BONKZEBU Submersible Pump Control Box is designed for direct installation and connection to a deep well submersible pump.

Passos d'instal·lació:

  1. Desconnexió d'alimentació: Ensure the main power supply to the installation area is completely turned off at the circuit breaker.
  2. Muntatge: Securely mount the control box in a dry, protected location, away from direct sunlight and extreme temperatures. Use appropriate fasteners for the mounting surface.
  3. Connexió de la bomba: Connect the submersible pump's power cable to the designated terminals inside the control box. Refer to the wiring diagram provided with your submersible pump for correct terminal identification.
  4. Connexió d'alimentació: Connect the incoming 110V AC power supply to the control box. The control box features a US plug for standard 110V outlets.
  5. Control box with US plug for 110V power

    Image 3.1: The control box features a US plug for 110V power supply.

  6. Posada a terra: Ensure proper grounding of the control box and the pump system according to local electrical codes.
  7. Prensacables: Tighten all cable glands securely to prevent moisture ingress and ensure strain relief for the cables.
  8. Close-up of cable glands on the control box for secure connections

    Image 3.2: Securely tightened cable glands.

  9. Comprovació final: Comproveu dues vegades que totes les connexions estiguin ben ajustades i correctes abans de restablir l'alimentació.

4. Instruccions de funcionament

Once the control box is properly installed and connected, operating your submersible pump is straightforward.

To Operate the Pump:

  1. Restaura l'alimentació: Turn on the main power supply to the control box at the circuit breaker.
  2. Activar la bomba: Locate the ON/OFF switch on the front of the control box. Flip the switch to the "ON" position to start the submersible pump.
  3. Close-up of the red ON/OFF switch on the control box

    Image 4.1: The red ON/OFF switch for pump activation.

  4. Deactivate Pump: To turn off the pump, flip the switch to the "OFF" position.

The built-in thermal protection circuit breaker will automatically trip if the pump motor overheats or draws excessive current, protecting the pump from damage. If this occurs, turn off the control box, allow the pump to cool, and investigate the cause of the overload before resetting and restarting.

5. Manteniment

Regular maintenance helps ensure the longevity and optimal performance of your BONKZEBU Submersible Pump Control Box.

  • Inspecció periòdica: Periodically inspect the control box for any signs of physical damage, corrosion, or loose connections.
  • Neteja: Mantingueu l'exterior de la caixa de control net i lliure de pols i deixalles. Utilitzeu un drap suau i sec per netejar-lo. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Comprovacions de connexió: Annually, or as needed, with the power disconnected, check all electrical connections for tightness.
  • Protecció del medi ambient: Ensure the control box remains protected from harsh environmental conditions, especially moisture.

For any internal maintenance or repairs, it is recommended to consult a qualified technician.

6. Solució De Problemes

This section provides solutions to common issues you might encounter with your control box.

ProblemaCausa possibleSolució
Pump does not start when switch is ON.
  • No power supply to the control box.
  • Thermal protection circuit breaker tripped.
  • Connexions elèctriques soltes.
  • Faulty pump motor.
  • Check main power supply and circuit breaker.
  • Turn off the control box, allow to cool, then reset the breaker (if applicable) and restart. Investigate overload cause.
  • (Apagar) Comproveu totes les connexions del cablejat per a l'estanquitat.
  • Consult a pump technician.
Pump runs intermittently or cycles too frequently.
  • Low water level in well.
  • Pressure switch malfunction (if applicable to your system).
  • Control box component issue.
  • Check well water level.
  • Inspect and test pressure switch.
  • Consult a qualified electrician or technician.
Control box feels hot.
  • Overload condition on the pump.
  • Poor ventilation around the control box.
  • Falla dels components interns.
  • Turn off power, allow to cool, investigate pump for issues (e.g., clogged impeller, low voltagi).
  • Assegureu-vos que hi hagi un flux d'aire adequat al voltant de la caixa.
  • Consult a qualified electrician or technician.

If you are unable to resolve an issue using the troubleshooting guide, contact a qualified electrician or the manufacturer for assistance.

7. Especificacions

CaracterísticaDetall
Número de modelBONKZEBUny28bhqrxa-11
Potència nominal2.2 kW (3.0 CV)
Condensador70 uf
Valoració actual20A
Voltage110V (endoll dels EUA)
MaterialAcrilonitril butadiè estirè (ABS), acer inoxidable
Pes de l'article1.55 lliures
Dimensions del paquet8.27 x 6.3 x 3.15 polzades
Protecció integradaThermal protection circuit breaker

For detailed electrical specifications, refer to the label on the control box itself.

Close-up of the technical specification label on the control box

Image 7.1: Technical specification label on the control box.

8. Garantia i Suport

For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact the seller directly.

If you require technical support or have questions not covered in this manual, please contact BONKZEBU customer service through your purchase platform or the official BONKZEBU weblloc.