Micsig SM-ETO3504

Manual d'usuari de l'oscil·loscopi de tauleta Micsig ETO3504 / ETO5004

Model: ETO3504 (SM-ETO3504) / ETO5004

1. Producte acabatview

The Micsig ETO Series Tablet Oscilloscopes (models ETO3504 and ETO5004) are advanced portable measurement instruments designed for professional use in laboratories and field environments. These devices feature a 14-inch integrated touch screen, a large-capacity battery, and a multi-tasking operating system, providing a comprehensive solution for waveform analysis.

Les característiques clau inclouen:

  • Up to 500MHz bandwidth and 3GSa/s samptaxa de ling.
  • 4 analog channels for multi-signal analysis.
  • 360Mpts memory depth for extended waveform capture.
  • 14-inch, 1920x1200 resolution touch screen display.
  • Integrated 13,500mAh Li-ion battery for portable operation.
Micsig ETO Series Tablet Oscilloscope with waveform display

Figure 1.1: Micsig ETO Series Tablet Oscilloscope in operation, displaying multiple waveforms.

2. Configuració inicial

2.1 Desembalatge i inspecció

Carefully remove the oscilloscope and all accessories from the packaging. Inspect for any signs of damage. Retain the packaging for future transport or storage.

2.2 Engegada i càrrega

The device includes a 13,500mAh Lithium Metal battery. Before first use, it is recommended to fully charge the battery using the provided power adapter. Connect the power adapter to the device's power input and then to a suitable power outlet. The charging indicator will show the charging status.

2.3 Connecting Probes and Accessories

The ETO series features 4 analog channels. Connect your probes to the BNC connectors on the device. The Mic-OPI™ probe interface automatically matches probe attenuation, simplifying setup. Ensure all connections are secure.

Micsig ETO Series Tablet Oscilloscope showing various interfaces and mounting options

Figura 2.1: Mésview of the oscilloscope's rear panel, showing the battery compartment, VESA mounting points, and various interfaces including USB, HDMI, and probe connections.

2.4 S'ha acabat la interfícieview

The oscilloscope is equipped with various interfaces for connectivity and expansion:

  • USB 3.0/2.0 Host: Per connectar dispositius d'emmagatzematge externs o perifèrics.
  • USB Device (Type-C): For PC connection and data transfer.
  • HDMI: For external display output.
  • Trigger Out: For external triggering.
  • Grounding Socket: Per a una connexió a terra segura.
  • Mic-OPI™ Probe Interface: For intelligent probe detection and compensation.

3. Instruccions de funcionament

3.1 User Interface and Touch Control

The ETO series features an intuitive operating interface designed for ease of use. The 14-inch full touch-capacitive display allows for direct interaction with waveforms and settings. Use gestures such as pinch-to-zoom, drag-to-pan, and tap-to-select for efficient operation.

Micsig ETO Series Tablet Oscilloscope showing touch control and UI elements

Figure 3.1: Demonstrates smooth touch control for waveform manipulation, intuitive user interface, large memory depth, segmented storage, low noise, and faster time base selection.

3.2 Mesures bàsiques

After connecting your probes and powering on the device, you can begin taking measurements. Adjust the vertical scale (Volts/Div) and horizontal time base (Sec/Div) using the on-screen controls or physical knobs (if available on your model). The oscilloscope automatically displays key waveform parameters.

3.3 Funcions avançades

  • Hardware Digital Filtering: Apply high-pass or low-pass filters to isolate specific frequency components of a signal.
  • Serial Bus Decoding and Analysis: Supports various serial bus protocols including RS-232/422/485, UART, CAN, CAN FD, LIN, SPI, I2C, and ARINC-429, MIL-STD-1553B. Decoded data can be exported to CSV format.
  • Multiple Trigger Functions: Offers various trigger types such as edge, pulse width, logic, Nth edge, runt, slope, bus, window, and interval to capture specific events.
  • Statistics Measurement: Automatically calculates average, maximum, minimum, and root mean square (RMS) values for up to 50,000 waveform events.
  • Funcions matemàtiques avançades: Includes addition, subtraction, multiplication, division, integration, differentiation, and FFT (Fast Fourier Transform) for detailed signal analysis.
  • Diversos File Desa: Save waveforms and measurement results in binary (.BIN) or CSV format. Images can also be saved.
Micsig ETO Series Tablet Oscilloscope showing advanced analysis features

Figure 3.2: Illustrates hardware digital filtering, serial bus decoding, multiple trigger functions, statistics measurement, advanced math functions, and diverse file saving options.

3.4 Control remot

The ETO series supports remote control via PC software, mobile applications, and HDMI screen projection. This allows for flexible operation and data analysis from a distance, enhancing efficiency in various testing scenarios.

4. Especificacions tècniques

Micsig ETO Series Tablet Oscilloscope specifications table

Figure 4.1: Detailed specifications for ETO5004 and ETO3504 models.

Micsig ETO Series Tablet Oscilloscope Specifications
CaracterísticaETO5004ETO3504
Ample de banda500 MHz350 MHz
Temps de pujada≤0.7ns≤1ns
Canals analògics44
S en temps realampTarifa ling3GSa/s3GSa/s
Profunditat de memòria360 Mpts360 Mpts
Max. Waveform Capture Rate230,000wfms/s
Sòl de soroll<90µVrms
InterfíciesUSB 3.0/2.0 Host, USB Type-C, HDMI, Trigger out
Mostra14 inches, 1920 x 1200 resolution, full touch
Bateria7.4V/13,500mAh Li-ion battery (included)
Dimensions / Pes Net353 * 245 * 56 mm / 3.6 kg (amb bateria)
Número de model de l'articleSM-ETO5004SM-ETO3504

5. Manteniment

5.1 Neteja

Per netejar el dispositiu, utilitzeu un suau, damp cloth. Avoid abrasive cleaners, solvents, or strong chemicals that could damage the screen or casing. Ensure the device is powered off and disconnected from all power sources before cleaning.

5.2 Cura de la bateria

For optimal battery life, avoid fully discharging the battery frequently. Store the device in a cool, dry place when not in use for extended periods. If storing for a long time, ensure the battery is charged to approximately 50% to prevent deep discharge.

5.3 Condicions ambientals

Operate and store the oscilloscope within the specified environmental ranges (temperature, humidity) to ensure proper function and longevity. Avoid exposure to extreme temperatures, direct sunlight, dust, and moisture.

6. Solució De Problemes

If you encounter issues with your Micsig ETO series oscilloscope, consider the following basic troubleshooting steps:

  • Sense energia: Ensure the power adapter is securely connected and the battery is charged. Check the power switch.
  • Pantalla sense senyal: Verify that probes are correctly connected to the input channels and the signal source. Check probe attenuation settings. Adjust vertical and horizontal scales.
  • Forma d'ona inestable: Adjust the trigger level and trigger source. Ensure the trigger mode is appropriate for the signal.
  • La pantalla tàctil no respon: Reinicieu el dispositiu. Si el problema persisteix, poseu-vos en contacte amb l'atenció al client.
  • Problemes de connectivitat: For USB or HDMI connections, ensure cables are properly seated and drivers (if applicable for PC software) are installed.

For more complex issues, refer to the detailed troubleshooting guide available on the Micsig official weblloc o contacteu amb el servei d'atenció al client.

7. Garantia i Suport

This product is manufactured by Shenzhen Micsig Technology Co., Ltd. For specific warranty information, please refer to the warranty card included with your product or visit the official Micsig weblloc. Els termes de la garantia solen cobrir els defectes de fabricació durant un període especificat a partir de la data de compra.

For technical support, service, or inquiries, please contact the Micsig Official Store or the manufacturer directly. Contact information can usually be found on the product packaging or the official Micsig weblloc.

Fabricant: Shenzhen Micsig Technology Co., Ltd.

Venedor: Micsig Official Store

© 2024 Micsig. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.