1. Producte acabatview
The Wisoqu JH-01 COP Ignition Waveform Probe is designed for measuring secondary ignition high-voltage waveforms in independent ignition systems, commonly known as Coil-on-Plug (COP) systems. This probe facilitates the analysis of ignition signals using an oscilloscope, providing a decay ratio of 5000:1 for accurate readings. Its specialized anti-interference design ensures reliable measurements, and it is compatible with various oscilloscope models.

Figura 1.1: The Wisoqu JH-01 COP Ignition Waveform Probe, showing its main body, cable, and BNC connector.
2. Especificacions
| Model | JH-01 COP |
| Número de model de l'article | Wisoqu4ut3orqv7g |
| Decay Ratio | 5000:1 |
| Longitud del producte | 43 cm (16.9 polzades) |
| Pes | Aproximadament 282 g (9.9 unces) |
| Tipus d'instal·lació | Coil-on-Plug |
| Tipus de servei del vehicle | Cotxe |
| Compatibilitat | Compatible with many kinds of oscilloscopes |

Figura 2.1: The probe's total length is 43 cm (16.9 inches), as indicated in the specifications.
3. Contingut del paquet
El paquet inclou els articles següents:
- 1 x Wisoqu JH-01 COP Ignition Waveform Probe
4. Configuració i connexió
Follow these steps to set up and connect the JH-01 COP probe to your oscilloscope:
- Prepare the Oscilloscope: Ensure your oscilloscope is powered on and properly configured for signal input.
- Connecteu la sonda: Connect the BNC connector of the JH-01 COP probe to the appropriate input channel on your oscilloscope.
- Col·loca el sensor: Place the sensor side of the probe tightly onto the independent ignition coil of the automobile engine. The probe is designed to induce the secondary ignition waveform without direct electrical contact.

Figura 4.1: The BNC connector for connecting the probe to an oscilloscope.

Figura 4.2: Illustrative diagram of the probe positioned on an engine's coil-on-plug for signal acquisition.
5. Instruccions de funcionament
Once the probe is connected and positioned, configure your oscilloscope settings to capture the ignition waveform effectively:
- Time-Base Setting: Set the oscilloscope's time-base to 1 ms.
- Vertical Grid Setting: Set the vertical grid to 1V.
- Waveform Stability: If necessary, select the "Normal" trigger mode on your oscilloscope and adjust the trigger position until the waveform remains stable on the screen.
- The probe is designed to easily capture ignition waveforms from automobiles.

Figura 5.1: The JH-01 COP probe actively measuring ignition waveforms on a vehicle engine.
6. Solució De Problemes
If you encounter issues while using the Wisoqu JH-01 COP probe, consider the following:
- Sense visualització de forma d'ona:
- Ensure the probe's BNC connector is securely attached to the oscilloscope.
- Verify the oscilloscope's input channel is correctly selected and enabled.
- Confirm the probe's sensor side is firmly and correctly positioned on the ignition coil.
- Check the oscilloscope's trigger settings. Adjusting the trigger level or mode (e.g., to Auto or Normal) might help.
- Forma d'ona inestable:
- Adjust the oscilloscope's time-base and vertical grid settings as recommended (1 ms time-base, 1V vertical grid).
- Ensure the probe is held steady and tightly against the ignition coil to minimize external interference.
- Experiment with different trigger settings on the oscilloscope to achieve a stable display.
- Incorrect Waveform Readings:
- Verify the oscilloscope's calibration.
- Ensure the probe is not damaged.
- Confirm the ignition system of the vehicle is functioning correctly.
7. Manteniment i cura
To ensure the longevity and optimal performance of your Wisoqu JH-01 COP probe, follow these maintenance guidelines:
- Neteja: Wipe the probe with a soft, dry cloth after each use. Avoid using harsh chemicals or abrasive cleaners.
- Emmagatzematge: Store the probe in a clean, dry environment, away from extreme temperatures and direct sunlight. Protect the cable and connectors from kinks or damage.
- Manipulació: Handle the probe with care. Avoid dropping it or subjecting it to excessive force, which could damage internal components or the sensor tip.
- Inspecció: Periodically inspect the cable, connectors, and probe body for any signs of wear, cuts, or damage. Do not use the probe if any damage is observed.
8. Garantia i Suport
Specific warranty information is not provided in the product details. For warranty claims, technical support, or further assistance, please contact the manufacturer, Wisoqu, or your point of purchase. Retain your purchase receipt as proof of purchase.
Podeu visitar el Wisoqu Store on Amazon for more information or to contact the seller.