Elitech Loget 260-TH

Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger User Manual

1. Introducció

This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.

1.1. Contingut del paquet

  • Elitech Loget 260-TH Data Logger (Reusable version)
  • Built-in 4G SIM Card
  • Manual d'usuari
  • Cable USB-Type C

2. Producte acabatview

The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Elitech Loget 260-TH Data Logger with labeled parts

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.

2.1. Identificació de components

  1. Pantalla LCD: Shows current readings, status, and alerts.
  2. Llum indicador LED: Provides visual status updates (e.g., OK, Alarm).
  3. Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
  4. Sensor intern: Measures ambient temperature and humidity.
  5. Back Hanging Hole: For mounting or securing the device.
  6. Botó d'inici / aturada: Initiates or terminates data logging.
  7. Número de sèrie: Unique identifier for the device.
  8. Sensor de llum: Detects ambient light levels.
  9. Data Transmission Indicator: Shows network activity and data upload status.

2.2. Característiques clau

  • Double Data Security: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
  • Multi-Source Sensing: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
  • Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
  • Sistema d'alarma integral: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platform. The device also provides local sound, screen, and indicator light alarms for offline events.
  • Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
  • iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.

3. Configuració

3.1. Càrrega inicial

Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.

3.2. Device Activation and Platform Connection

  1. Encès: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
  2. Connexió de xarxa: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
  3. iCold Account Setup:
    • Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web plataforma (http://new.i-elitech.com).
    • Registra't per obtenir un compte nou o inicia la sessió si ja en tens un.
    • Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
  4. Configuració: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.

4. Instruccions de funcionament

4.1. Inici i aturada del registre

  • Comença a registrar: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
  • Atura el registre: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.

4.2. Mode avió

Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Elitech Loget 260-TH Data Logger displaying Flight Mode feature

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.

  • Activació manual: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
  • Scheduled Activation: Configure specific times for airplane mode activation via the iCold platform.
  • Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.

4.3. Data Access and Alarms

Elitech Loget 260-TH Data Logger next to a smartphone displaying the iCold app interface with data graphs

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.

  • Dades en temps real: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web plataforma.
  • Dades històriques: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
  • Notificacions d'alarma: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.
Elitech Loget 260-TH Data Logger with a laptop showing PDF and CSV report export options from the iCold platform

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.

5. Manteniment

5.1. Cura de la bateria

  • Recharge the device regularly, especially if it will be stored for an extended period.
  • Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.

5.2. Neteja

  • Netegeu el dispositiu amb un drap suau i sec.
  • No utilitzeu netejadors ni dissolvents abrasius, ja que poden danyar el casing or sensors.

5.3. Emmagatzematge

  • Guardeu el dispositiu en un lloc fresc i sec, lluny de la llum solar directa.
  • Assegureu-vos que la bateria estigui parcialment carregada (al voltant del 50%) abans d'emmagatzemar-la a llarg termini.

6. Solució De Problemes

6.1. El dispositiu no s'encén

  • Ensure the device is fully charged. Connect it to a power source using the USB Type-C cable.
  • Verify that the 'Start/Stop' button is pressed and held for the required duration.

6.2. No 4G Network Connection

  • Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
  • Ensure airplane mode is not active.
  • Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.

6.3. Data Not Uploading to iCold Platform

  • Confirm the device has a stable 4G connection.
  • Verify that the device is correctly added and configured in your iCold account.
  • Check the upload interval settings in the iCold platform.

6.4. Lectures inexactes

  • Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
  • Allow the device to stabilize in a new environment for a few minutes before taking critical readings.

7. Especificacions

ParàmetreValor
Número de modelUS-LogEt260-TH-10PACK
Temperature Range (Internal)-30 ℃ a 60 ℃ (-22 ℉ a 140 ℉)
Humidity Range (Internal)0% a 100% HR
Interval del sensor de llumDe 0 a 52000 lux
Shock Sensor Range0 g a 16 g
Seguiment d'ubicacióLBS (Location-Based Service)
Capacitat d’emmagatzematge de dades100,000 points (offline)
Connectivitat4G (Built-in SIM Card)
Interval de càrregaConfigurable (1 minute to 24 hours)
Tipus de bateriaIó de liti (inclòs)
InterfícieUSB tipus C
ComplimentDo160 (Aviation Safety), FDA CFR 21 Part 11

8. Garantia i Suport

For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. directly. Refer to the official Elitech website or the contact information provided with your purchase for the most up-to-date support details.

Plataforma Elitech iCold: http://new.i-elitech.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.