Goodman GLXS4BA2410CAPTA2422B3

Goodman GLXS4BA2410 Condenser and CAPTA2422B3 Vertical Coil AC System User Manual

Model: GLXS4BA2410CAPTA2422B3

1. Producte acabatview

This manual provides essential information for the Goodman 2 Ton 14.3 SEER2 AC Only System, comprising the GLXS4BA2410 condenser and CAPTA2422B3 vertical coil. This system is designed to provide efficient cooling for your home. Please note that this is not a complete system and requires a separate furnace or modular blower for full functionality. Proper installation by a qualified HVAC professional is crucial for safe and optimal performance.

Goodman GLXS4BA2410 Condenser and CAPTA2422B3 Vertical Coil AC System

Image 1: Goodman GLXS4BA2410 Condenser and CAPTA2422B3 Vertical Coil AC System. This image shows both the outdoor condenser unit and the indoor vertical coil.

2. Informació de seguretat

WARNING: Installation and servicing of air conditioning equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only trained and qualified personnel should install, repair, or service this equipment.

  • Desconnecteu sempre l'alimentació abans de fer el servei.
  • This system uses R-32 refrigerant, which is mildly flammable. An R-32 leak detection system is required for safe operation, particularly when used with a furnace.
  • Ensure proper ventilation during installation and servicing.
  • Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi guants i protecció ocular.
  • Refer to all local and national safety codes and regulations.

3. Components del producte

3.1. GLXS4BA2410 Air Conditioner Condenser

Goodman GLXS4BA2410 Air Conditioner Condenser

Image 2: Goodman GLXS4BA2410 Air Conditioner Condenser. This is the outdoor unit responsible for releasing heat from your home.

The GLXS4BA2410 is a 2 Ton, 14.3 SEER2 single-stage AC condenser. It features service valves, gauge ports, and inspection points for ease of maintenance. The unit is pre-charged for 15 feet of tubing and includes a factory-installed filter drier for cleaner operation.

3.2. CAPTA2422B3 Vertical Coil

Goodman CAPTA2422B3 Vertical Coil

Image 3: Goodman CAPTA2422B3 Vertical Coil. This indoor coil works with your furnace or air handler to cool the air.

The CAPTA2422B3 is a vertical coil designed for optimal airflow and heat transfer. Constructed with corrosion-resistant aluminum and featuring grooved tubing, it undergoes rigorous helium pressure tests to ensure quality and durability. This coil is intended to be paired with a furnace or modular blower.

4. Pautes d'instal·lació

Installation of this Goodman AC system must be performed by a qualified HVAC technician. Incorrect installation can lead to system malfunction, safety hazards, and void the product warranty.

  • Ensure the GLXS4BA2410 condenser and CAPTA2422B3 coil are compatible with your existing or new furnace/blower.
  • Proper sizing of the system to your home's cooling load is essential for efficiency and comfort.
  • The R-32 refrigerant requires specific tools and procedures for handling and charging.
  • An R-32 leak detection system must be installed, especially when the system is paired with a furnace, to ensure safety.
  • Follow all manufacturer's instructions and local building codes.

4.1. Condenser and Coil Combination

For detailed information regarding the combination of condenser and coil, please watch the following video:

Video 1: Condenser with Coil Combination. This video explains important considerations when pairing a condenser with a coil.

4.2. Understanding Your System Type

To ensure proper installation and compatibility, it is important to understand the type of HVAC system you have. The following video provides an overview of different system types:

Video 2: What type of system do you have? This video helps identify common HVAC system configurations.

5. Instruccions de funcionament

Once installed by a qualified technician, your Goodman AC system will operate automatically based on your thermostat settings. For optimal performance:

  • Set your thermostat to your desired cooling temperature.
  • Avoid frequently adjusting the thermostat, as this can reduce efficiency.
  • Ensure all vents are open and unobstructed for proper airflow.
  • Keep windows and doors closed while the system is operating.

6. Manteniment

Regular maintenance is essential for the longevity and efficiency of your AC system. It is recommended to have your system inspected and serviced annually by a qualified HVAC technician.

  • Substitució del filtre: Check and replace your air filter monthly, or as recommended by your technician, to ensure proper airflow and indoor air quality.
  • Neteja de la unitat exterior: Keep the area around the outdoor condenser unit clear of debris, leaves, and vegetation to prevent airflow obstruction.
  • Neteja de bobines: The indoor and outdoor coils should be professionally cleaned periodically to maintain heat transfer efficiency.
  • Drain Line Check: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.

7. Solució De Problemes

If you experience issues with your AC system, consider the following basic troubleshooting steps before contacting a technician:

  • Sense refrigeració: Check your thermostat settings to ensure it's set to 'Cool' and the temperature is below the current room temperature. Verify that the circuit breaker for the HVAC system has not tripped.
  • Flux d'aire feble: Check and replace the air filter if it's dirty. Ensure all supply and return vents are open.
  • Sorolls inusuals: Strange noises can indicate a mechanical issue. Turn off the system and contact a qualified technician.
  • El sistema no s'encén: Check the thermostat for power and correct settings. Inspect the outdoor unit for any visible damage or obstructions.

For any persistent issues or complex problems, always contact a qualified HVAC professional.

8. Especificacions

CaracterísticaDetall
MarcaGoodman
Número de modelGLXS4BA2410CAPTA2422B3
Capacitat2 tones
Potència de refrigeració24000 unitats tèrmiques britàniques
Ràtio d'eficiència energètica estacional (SEER2)14.3
Tipus de refrigerantR-32
Tipus de bobinaVertical
ColorArchitectural Gray
Pes de l'article197 lliures
Certificat AHRIYes, Certificate Number 215213886

8.1. Energy Efficiency Rating

EnergyGuide Label for Goodman GLXS4BA2410 AC Unit

Image 4: EnergyGuide Label. This label indicates the efficiency rating of the GLXS4BA2410 condenser.

8.2. SEER2 Regulations

The Seasonal Energy Efficiency Ratio 2 (SEER2) is a new standard for measuring the energy efficiency of air conditioning systems. The following video provides important information about these regulations:

Video 3: SEER2 Regulations - 01. This video explains the updated energy efficiency standards for HVAC equipment.

8.3. R-32 Refrigerant Information

This system utilizes R-32 refrigerant. It is important to understand the characteristics and regulations surrounding this refrigerant. The following videos offer insights into R-32:

Video 4: R-32 Fact vs Fiction. This video clarifies common misconceptions about R-32 refrigerant.

Video 5: Info about the refrigerant regulations. This video provides details on current refrigerant regulations affecting HVAC systems.

9. Informació de la garantia

This Goodman AC system comes with a Garantia limitada de peces de 10 anys. To qualify for the full warranty, the system must be installed by a qualified installer and registered online within 60 days of installation. Online registration is not required in California.

10 Year Limited Warranty Shield

Image 5: 10 Year Limited Warranty Shield. This emblem signifies the product's warranty coverage.

For complete warranty details and terms, please contact Goodman customer support or your qualified installer.

10. Suport i contacte

For technical assistance, service, or warranty inquiries, please contact your installing HVAC professional. They are best equipped to diagnose and resolve any issues with your Goodman AC system.

You may also visit the official Goodman weblloc web per obtenir informació addicional sobre el producte i recursos d'assistència.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.