Dasan DA-RN3012C6-BG

Dasan Rainfall Dual Shower System User Manual

Model: DA-RN3012C6-BG

Brand: Dasan

1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Dasan Rainfall Dual Shower System, model DA-RN3012C6-BG. This system features a 12-inch round rainfall shower head, a 6-inch round wall-mounted shower head, and a handheld shower, all controlled by an upgraded button diverter and a pressure balance valve.

Please read this manual thoroughly before installation and use to ensure proper function and longevity of your shower system. Keep this manual for future reference.

Dasan Dual Shower System in use, showing water flowing from both shower heads and the handheld shower.

Image 1.1: Dasan Dual Shower System in operation, illustrating the simultaneous use of multiple shower functions.

2. Components inclosos

Verify that all components listed below are present and undamaged before beginning installation.

Explotat view of Dasan Dual Shower System components with numbered labels.

Image 2.1: All components included in the Dasan Rainfall Dual Shower System package.

  1. 12" Round Shower Head
  2. Shower Valve (with rough-in box)
  3. Placa de cara
  4. Mànec de vàlvula
  5. 6" Round Shower Head
  6. Ceiling Mount Shower Arm (for 12" head)
  7. Dutxa de mà
  8. 59" Shower Hose
  9. Wall Mount Shower Arm (for 6" head)
  10. Handheld Shower Bracket
  11. Trim Plate (Long Shower Arm)
  12. Trim Plate (Short Shower Arm)
  13. Escutcheon (Shower Bracket)
  14. Kit de muntatge (cargols, ancoratges)
  15. Manual d'instal·lació (aquest document)
All components of the Dasan Brushed Gold Dual Shower System laid out.

Imatge 2.2: acabatview of the Dasan Rainfall Dual Shower System components.

3. Especificacions del producte

Característica Especificació
Número de model DA-RN3012C6-BG
Marca Dasan
Color Or raspallat
Material Llautó, acer inoxidable
Tipus d'acabat Raspallat
Nombre de nanses 1 (for temperature control)
Pes de l'article 5.69 quilograms (12.51 lliures)
Tipus de muntatge Wall Mount (for valve, 6" head, handheld), Ceiling Mount (for 12" head)
Caudal 1.8 GPM (galons per minut)
Shower Head Sizes 12-inch Round, 6-inch Round
Longitud de la mànega de mà 59 polzades
Tipus de vàlvula Pressure Balance Valve with Sedal Ceramic Cartridge
Tipus de desviador Button Diverter (3 independent buttons)
Detallada view of the shower valve body, Sedal ceramic cartridge, and button diverter mechanism.

Image 3.1: Internal components of the Dasan shower valve, highlighting the durable Sedal ceramic cartridge and forged brass body.

4. Instruccions d'instal·lació

Professional installation is recommended. Ensure all local plumbing codes are followed. Turn off the main water supply before starting installation.

4.1. Tools and Materials Required (Not Included):

  • Clau ajustable
  • Pipe sealant tape (Teflon tape)
  • Tornavís (Phillips i cap pla)
  • Trepant
  • Nivell
  • Cinta mètrica
  • Ulleres de seguretat

4.2. Passos generals d'instal·lació:

  1. Prepara el mur: Ensure the wall cavity is clear and properly reinforced for the shower valve and arms.
  2. Install the Rough-in Valve: Mount the shower valve body securely within the wall, ensuring it is level and at the correct depth according to the trim plate specifications. Connect the hot and cold water lines to the designated inlets on the valve.
  3. Connect Outlet Pipes: Connect the outlet pipes from the valve to the locations for the 12-inch shower head (ceiling mount), 6-inch shower head (wall mount), and handheld shower bracket.
  4. Install Shower Arms: Securely install the ceiling-mount shower arm for the 12-inch shower head and the wall-mount shower arm for the 6-inch shower head. Apply pipe sealant tape to all threaded connections.
  5. Install Shower Heads: Attach the 12-inch round shower head to the ceiling arm and the 6-inch round shower head to its wall arm. Ensure they are tightened properly.
  6. Install Handheld Shower Bracket and Hose: Mount the handheld shower bracket to the wall. Connect the 59-inch shower hose to the handheld shower and the outlet on the valve. Place the handheld shower into its bracket.
  7. Instal·leu el kit d'acabat: Once all plumbing connections are complete and tested for leaks, install the face plate, valve handle, and trim plates/escutcheons.
  8. Prova el sistema: Turn on the main water supply and check all connections for leaks. Test the functionality of each shower component and the temperature control.

5. Instruccions de funcionament

Your Dasan Rainfall Dual Shower System is designed for ease of use with its intuitive button diverter and temperature control handle.

5.1. Control de temperatura:

  • The main handle on the face plate controls the water temperature.
  • Rotate the handle to adjust between hot and cold water. The pressure balance valve maintains a consistent temperature, preventing sudden changes.

5.2. Function Selection (Button Diverter):

The system features three independent buttons to control the water flow to each shower component. These can be operated simultaneously.

  • Botó 1: Activates/Deactivates the 12-inch Rainfall Shower Head.
  • Botó 2: Activates/Deactivates the 6-inch Wall-Mounted Shower Head.
  • Botó 3: Activates/Deactivates the Handheld Shower.

Press a button to turn on the corresponding shower function. Press it again to turn it off. You can use any combination of these functions simultaneously for a customized shower experience.

Close-up of the shower valve with three buttons and a temperature control handle, illustrating simultaneous function.

Image 5.1: The button diverter allows for simultaneous activation of multiple shower functions.

Woman enjoying the rainfall shower head with air injection technology, showing water saving and pressure increasing benefits.

Image 5.2: The 12-inch rainfall shower head features air injection technology for enhanced pressure and water saving.

6. Cura i Manteniment

Proper care and maintenance will ensure the longevity and appearance of your Dasan shower system.

6.1. Neteja:

  • Clean the surfaces regularly with a soft cloth and mild soap or a non-abrasive cleaner specifically designed for brushed finishes.
  • Avoid using abrasive cleaners, harsh chemicals, or scouring pads, as these can damage the brushed gold finish.
  • For shower heads with silicone nozzles, gently rub the nozzles with your finger to dislodge any mineral buildup.
  • Wipe dry with a soft cloth after cleaning to prevent water spots.
Close-up of a rainfall shower head with a finger cleaning the soft silicone nozzles.

Image 6.1: Easy-to-clean silicone nozzles on the rainfall shower head.

6.2. Atenció general:

  • Comproveu periòdicament totes les connexions per evitar fuites.
  • If water flow decreases, check for mineral buildup in the shower heads or aerators and clean as necessary.

7. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves solucions.

Problema Causa possible Solució
Low water flow from shower heads. Mineral buildup in nozzles; partially closed shut-off valves; low water pressure in household. Clean shower head nozzles by gently rubbing them. Ensure shut-off valves are fully open. Consult a plumber if household water pressure is consistently low.
Water temperature fluctuates. Pressure balance valve issue; hot/cold water supply imbalance. Ensure hot and cold water supplies are stable. If problem persists, contact a qualified plumber to inspect the pressure balance valve.
Fuites a les connexions. Loose connections; insufficient pipe sealant tape. Turn off water supply. Tighten connections. If necessary, disassemble, reapply pipe sealant tape, and reassemble.
Diverter buttons not working correctly. Debris in diverter mechanism; worn cartridge. Flush the system. If the issue persists, the diverter cartridge may need inspection or replacement by a professional.

8. Informació de la garantia

Dasan provides the following limited warranty for this product:

  • Ús residencial: Garantia limitada de 10 anys
  • Ús comercial: Garantia limitada de 5 anys

This warranty covers defects in material and workmanship under normal use and service. It does not cover damage resulting from improper installation, misuse, abuse, accident, or unauthorized repairs. Please retain your proof of purchase for warranty claims.

9. Atenció al client

For technical assistance, replacement parts, or warranty inquiries, please contact Dasan customer support through the retailer where the product was purchased or visit the official Dasan weblloc per obtenir informació de contacte.

When contacting support, please have your model number (DA-RN3012C6-BG) and proof of purchase readily available.

© 2025 Dasan. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.