Informació important de seguretat
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Seguretat elèctrica: Always disconnect power to the spa before installing or servicing the ozone generator. Ensure all electrical connections are secure and comply with local electrical codes.
- Ozone Exposure: Ozone is a powerful oxidizer. While beneficial for water purification, direct inhalation of high concentrations can be harmful. Ensure proper ventilation and avoid direct exposure to the ozone output.
- Contacte amb l'aigua: This device is designed for use with spa water systems. Do not submerge the main unit in water. Ensure all tubing connections are watertight to prevent leaks.
- Nens i animals de companyia: Keep the ozone generator and its components out of reach of children and pets.
- Ús previst: Use this product only for its intended purpose of spa water purification. Any other use may void the warranty and pose safety risks.
Producte acabatview
The Briidea Ozone Generator LD-149 is designed to enhance spa water purification by producing ozone, which helps to refresh water without relying solely on chemical additives. This unit utilizes Corona Discharge (CD) technology for reliable performance.
Característiques principals:
- Enhanced Ozone Purification: Effectively refreshes spa water.
- Upgraded Sampling Module: Includes a 6mm food-grade silicone tube and a non-pressure check valve for improved performance and safety.
- Compatibilitat versàtil: Compatible with Hot Spring, Tiger River, and Limelight spa models manufactured from 1995 to current, including Watkins Freshwater III Ozone System 72602.
- Funció de temporitzador convenient: Features a user-friendly LED display with timer options for 10 minutes, 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, and 5 hours.
- Construcció duradora: Built with robust materials and Corona Discharge (CD) technology for longevity and reliable operation.

This image displays the Briidea Ozone Generator LD-149 unit alongside icons highlighting its main features: enhanced ozone purification, an upgraded sampling module, Corona Discharge (CD) technology, a timer function, and versatile compatibility with various spa models.
Contingut del paquet
Verifiqueu que tots els components siguin presents al paquet abans de continuar amb la instal·lació:
- Briidea Ozone Generator Unit
- Cable d'alimentació
- Ozone-resistant Tubing (6mm food-grade silicone tube)
- Non-pressure Check Valve
- Injector
- Connector de 4 clavilles

This image shows the individual components of the upgraded sampling module: a 4-prong connector, a non-pressure check valve, and food-grade silicone tubing, which are part of the installation package.
Instruccions d'instal·lació
Installation should be performed by a qualified individual. Always ensure the spa's power is disconnected before beginning installation.
- Identificar els punts de connexió: Locate the spa controller, pump, spa supply, and spa return lines on your hot tub system.
- Install Injector: Integrate the provided injector into the spa's return line. Ensure a secure and watertight fit.
- Connect Check Valve: Attach the non-pressure check valve to one end of the ozone-resistant tubing. The check valve prevents water backflow into the ozone generator.
- Connect Tubing to Injector: Connect the other end of the ozone-resistant tubing (with the check valve) to the injector installed in the spa return line.
- Connect Generator to Tubing: Connect the ozone generator's output port to the remaining open end of the ozone-resistant tubing.
- Connexió d'alimentació: Connect the 4-prong connector from the ozone generator to the designated ozone power receptacle on your spa's control system, if available. If not, use the provided power cord to connect the generator to a suitable electrical outlet, ensuring it is GFCI protected.
- Verifica les connexions: Double-check all connections for tightness and proper orientation.

Figure 1 provides a detailed diagram for installing the ozone generator. It shows how the ozone generator connects via ozone tubing to a check valve and an injector, which is integrated into the spa's return line, alongside the spa controller and pump.

This image highlights the compatibility of the Briidea Ozone Generator with various spa brands, including Hot Spring, Tiger River, Hot Spot, and Limelight hot tub spa models manufactured from 1995 to the present.
Instruccions de funcionament
Once installed and powered, the Briidea Ozone Generator is simple to operate:
- Encès/apagat: Premeu el botó Poder button on the unit to turn the ozone generator on or off.
- Estableix el temporitzador: Utilitza el Temps+ i temps- buttons to select your desired operating duration. The available timer options are 10 minutes, 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, and 5 hours.
- Pantalla LED: The LED screen will show the currently selected timer setting.
- Indicador de treball: A dedicated light labeled 'Working' will illuminate when the ozone generator is actively producing ozone.
Important Note on Automatic Operation:
This ozone generator model is designed to run for the set duration and then stop. It does not feature an automatic daily restart function. After a timed cycle completes, the unit will require manual intervention (pressing the power button or cycling the power) to begin a new operation cycle.

This image illustrates the user-friendly timer function of the ozone generator, displaying the control panel with Power, Time+, and Time- buttons, and an LED screen. It shows various timer settings available, from 5 minutes up to 5 hours.
Manteniment
Regular maintenance ensures optimal performance and longevity of your ozone generator:
- Tubing and Check Valve Inspection: Periodically inspect the ozone-resistant tubing and the non-pressure check valve for any signs of wear, kinks, blockages, or damage. Replace these components if necessary, typically annually, to prevent water backflow and ensure efficient ozone delivery.
- Neteja de la unitat: Keep the exterior of the ozone generator unit clean and free from dust or debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or allow water to enter the unit.
- Emmagatzematge: If the spa or ozone generator will not be in use for an extended period, disconnect the unit from power and store it in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
Resolució de problemes
Consulteu la taula següent per veure els problemes habituals i les seves solucions:
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén | Sense font d'alimentació | Check power cord connection to the unit and the electrical outlet. Ensure the outlet is functional. |
| No ozone production (Working light off) | Tubs doblegats o bloquejats | Inspect ozone tubing for any kinks or obstructions and clear them. |
| Check valve faulty or installed incorrectly | Ensure the check valve is installed in the correct direction and is not blocked. Replace if faulty. | |
| Generator malfunction | If all other checks fail, the generator may be faulty. Contact customer support. | |
| Unit does not restart automatically after timer cycle | Expected behavior for this model | This unit requires manual restart or power cycling after each timed operation. It does not feature an automatic daily restart function. |
| Unit is loud during operation | Soroll normal de funcionament | Some operational noise is expected from ozone generators. Ensure the unit is securely mounted and not vibrating against other surfaces. |
Especificacions
- Marca: briidea
- Nom del model: LD-149
- Color: Negre
- Dimensions del producte (aprox.): 3.9 inches (W) x 6.2 inches (H) (Main unit, excluding cables/tubing)
- Pes de l'article: 1.65 lliures (0.75 quilograms)
- Font d'alimentació: AC
- Tecnologia de generació d'ozó: Corona Discharge (CD)
- Compatibilitat: Watkins Freshwater III Ozone System 72602, Hot Spring, Tiger River, Limelight Spa Models 1995 to Current
Garantia i Suport
For warranty information, technical support, or assistance with troubleshooting beyond what is covered in this manual, please contact Briidea customer service. Keep your purchase receipt as proof of purchase for warranty claims.