1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN DHC312 Humidity Controller. This pre-wired digital humidistat is designed to regulate and maintain desired humidity levels in various environments, offering both humidification and dehumidification capabilities. It also features a real-time temperature display for comprehensive environmental management.

Image 1.1: The DIGITEN DHC312 Humidity Controller, showing the main unit, power outlet, power plug, and humidity sensor.
2. Característiques del producte
- High-Precision Swiss-Imported Humidity Sensor: Regulates humidity within 5% to 99% RH with an accuracy of ±3%RH.
- Visualització de temperatura en temps real: Monitors ambient temperature (Note: The device measures temperature but does not control it).
- Convenient Plug & Play Operation: Non-programmable design for ease of use; no complex programming required.
- Intelligent Dual-Stage Control: Seamlessly switches between humidification and dehumidification modes. Requires humidifiers with automatic restart functions.
- Aplicacions versàtils: Suitable for home brewing, reptile habitats, greenhouses, mushroom cultivation, grow tents, meat drying, and incubation.
- Funcions addicionals: Supports switching between °C/°F, calibration, and compressor delay functions.

Imatge 2.1: acabatview of the DHC312 controller highlighting its key features such as large screen, dual-mode operation, and plug-and-play functionality.

Imatge 2.2: Detallada view of the high-precision Swiss-imported humidity sensor, emphasizing its compact design and internal components.
3. Contingut del paquet
The DIGITEN DHC312 Humidity Controller package includes the following items:
- 1 x DIGITEN DHC312 Humidity Controller Unit
- 1 x Manual d'usuari

Image 3.1: The complete package contents, showing the main controller unit, the dual-outlet power strip, the humidity sensor, and the instruction manual.
4. Especificacions
| Especificació | Valor |
|---|---|
| Número de model | DHC312 |
| Interval de control | 5-99% HR |
| Resolució d’humitat | 0.1% HR |
| Precisió | ±3% HR |
| Mode de control | Humidify or Dehumidify |
| Potència d'entrada | 100~240VAC, 50/60Hz |
| Relay Contact Capacity (Humidify) | 10A, 100~240VAC |
| Relay Contact Capacity (Dehumidify) | 10A, 100~240VAC |
| Sensor Lead Length | 2 m / 6.56 peus |
| Longitud del cable d'alimentació d'entrada | 150 cm / 4.92 peus |
| Longitud del cable d'alimentació de sortida | 18 cm / 0.59 peus |
| Color | Negre |
| Material | Plàstic |
| Tipus de visualització | Digital |
| Pes de l'article | 15.8 unces |
| Dimensions del paquet | 7.8 x 3.5 x 3.5 polzades |

Image 4.1: Visual representation of the controller's dimensions and key technical specifications.
5. Instruccions de configuració
The DIGITEN DHC312 is designed for plug-and-play convenience. Follow these steps for initial setup:
- Col·locació: Position the main controller unit in a stable location.
- Connexió del sensor: Ensure the humidity sensor is securely connected to the main controller unit. Place the sensor probe in the environment where humidity needs to be monitored and controlled. Avoid placing it near direct airflow or heat sources for accurate readings.
- Connexió d'alimentació: Plug the controller's power plug into a standard electrical outlet (100-240VAC).
- Connexió de l'aparell:
- For humidification, plug your humidifier into the outlet labeled "HUMIDIFICATION" on the dual-stage power strip.
- For dehumidification, plug your dehumidifier or exhaust fan into the outlet labeled "DEHUMIDIFICATION".
Important: Ensure your humidifier has an automatic restart function for seamless operation with this controller.

Image 5.1: The dual-relay power strip connected to the controller, illustrating the separate outlets for humidification and dehumidification appliances.
6. Instruccions de funcionament
The DHC312 features a clear digital display and intuitive buttons for easy operation.
6.1 Mostra finalview

Imatge 6.1: Detallada view of the controller's LCD screen, indicating various display elements such as current temperature, current humidity, and set humidity.
- Mode de treball: Indicates whether the unit is in humidification or dehumidification mode.
- Temperatura actual: Displays the real-time ambient temperature.
- Humitat actual: Shows the real-time ambient humidity percentage.
- Setting Humidity (SET): Displays the target humidity percentagi has posat.
- Difference (DIFF): Indicates the humidity differential setting.
- Calibration (CA): Indicates if calibration is active.
6.2 Establiment de la humitat objectiu
- Premeu el botó Up (▲) o Avall (▼) button to adjust the target humidity value (SET).
- After setting the desired value, wait approximately 5 seconds. The controller will automatically save the setting and return to the normal display mode.
6.3 Advanced Settings (Temperature Unit, Difference, Calibration)
- Premeu llargament el botó SET button for 3 seconds until the °C or °F indicator flashes.
- While the indicator is flashing, short press the SET button to cycle through the advanced settings: Temperature Unit (°C/°F), Difference (DIFF), and Calibration (CA).
- Utilitza el Up (▲) o Avall (▼) buttons to adjust the value for the selected setting.
- Premeu llargament el botó SET button for 3 seconds to save the changes and exit the advanced settings menu.

Image 6.2: Step-by-step guide on setting the target humidity and accessing advanced functions like °C/°F switching, difference, and calibration.
6.4 Humidification and Dehumidification Logic
The controller operates based on the set humidity value and the difference (DIFF) setting:
- Humidificació: The humidification outlet turns ON when the measured humidity is ≤ (Setting Value - DIFF). It turns OFF when the measured humidity is ≥ Setting Value.
- Deshumidificació: The dehumidification outlet turns ON when the measured humidity is ≥ (Setting Value + DIFF). It turns OFF when the measured humidity is ≤ Setting Value.

Imatge 6.3: Ex.amples of the controller managing humidity in a greenhouse (humidification) and a poultry farm (dehumidification).
7. Calibració
The DHC312 allows for humidity calibration to ensure accuracy. If you have a trusted reference hygrometer, you can adjust the controller's reading.
- Access the advanced settings menu by long pressing the SET botó durant 3 segons.
- Premeu breument SET button until 'CA' (Calibration) is displayed.
- Utilitza el Up (▲) o Avall (▼) buttons to adjust the calibration value. This value will offset the measured humidity.
- Premeu llargament el botó SET botó durant 3 segons per desar i sortir.
8. Solució De Problemes
If you encounter issues with your DIGITEN DHC312, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla del controlador està apagada. | Sense font d'alimentació. | Check if the power plug is securely inserted into a live outlet. Verify the outlet is functioning. |
| Lectures d'humitat inexactes. | Sensor dirty or improperly placed; calibration needed. | Clean the sensor gently. Relocate the sensor away from direct airflow or heat. Perform a calibration as described in Section 7. |
| Humidifier/Dehumidifier not activating. | Incorrect settings; appliance not working; appliance lacks auto-restart. | Verify the target humidity and DIFF settings. Ensure the appliance is plugged into the correct outlet and is functional. Confirm your appliance has an auto-restart function. |
| La visualització de la temperatura és incorrecta. | Sensor issue or environmental factors. | Ensure the sensor is not exposed to extreme temperatures or direct sunlight. The controller measures, but does not control, temperature. |
9. Manteniment
To ensure the longevity and accurate performance of your DIGITEN DHC312 Humidity Controller, follow these maintenance guidelines:
- Neteja: Periodically wipe the main unit and display with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- Cura del sensor: Keep the humidity sensor clean and free from dust, debris, or moisture buildup. Gently clean the sensor housing if necessary.
- Emmagatzematge: If storing the controller for an extended period, disconnect it from power, clean it, and store it in a cool, dry place away from direct sunlight and extreme temperatures.
- Condicions ambientals: Avoid exposing the controller to corrosive gases, high humidity (beyond its operating range), or extreme temperatures, which can affect its performance and lifespan.
10. Garantia i Suport
DIGITEN provides a one-year warranty for any quality problems encountered with this product. For technical support, warranty claims, or further assistance, please contact DIGITEN customer service through your purchase platform or the official DIGITEN weblloc.