DATOUBOSS 48V 11000W

DATOUBOSS 11KW Hybrid Solar Inverter

Model: 48V 11000W

Manual d'usuari

1. Introducció

This user manual provides detailed instructions for the installation, operation, and maintenance of the DATOUBOSS 11KW Hybrid Solar Inverter. This inverter is designed to efficiently convert DC power from solar panels and batteries into AC power for various household and office appliances. It supports both on-grid and off-grid applications, parallel operation, and battery-less functionality.

Llegiu atentament aquest manual abans de la instal·lació i el funcionament per garantir un ús correcte i evitar danys a la unitat o als equips connectats.

2. Instruccions de seguretat

Adhering to safety precautions is crucial during the installation and operation of the hybrid solar inverter. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure all power sources (PV array, battery, utility grid) are disconnected before performing any wiring or maintenance.
  • Only qualified personnel should install and service this inverter.
  • No desmunteu l'inversor. No hi ha peces a l'interior que l'usuari pugui reparar.
  • Instal·leu l'inversor en una zona ben ventilada, allunyada de materials inflamables i de la llum solar directa.
  • Assegureu-vos de posar a terra correctament l'inversor.
  • Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses, during installation.
  • Mantingueu els nens i les persones no autoritzades allunyats de l'inversor.

3. Producte acabatview

The DATOUBOSS 11KW Hybrid Solar Inverter is a versatile power solution integrating a solar charge controller, inverter, and battery charger into one compact unit. It is designed to provide uninterrupted power supply.

3.1 Característiques clau

  • 11KW Pure Sine Wave Output: Provides stable and clean power suitable for sensitive electronics.
  • Integrated 150A MPPT Solar Charge Controller: Maximitza la captació d'energia dels panells solars.
  • Parallel Operation Support: Up to 9 units can be connected in parallel for increased capacity.
  • Grid Integration Capability: Supports feeding excess solar power back into the public grid (user responsible for grid connection procedures).
  • Funcionament sense bateria: Can power loads directly from PV or utility grid without a battery (note: parallel operation requires batteries).
  • Dual MPPT Inputs: Allows for two independent PV array inputs for optimized solar energy utilization.
  • Multiple Charging and Output Modes: Offers flexibility for various application requirements.
  • Protecció integral: Inclou curtcircuit, sobreintensitat, sobrevoltage, minvartage, overload, backfill, and overtemperature protection.

3.2 Product Components and Interface

Familiarize yourself with the inverter's external components and connection points.

DATOUBOSS 11KW Hybrid Solar Inverter front view

Figura 3.2.1: Frontal view of the DATOUBOSS 11KW Hybrid Solar Inverter.

DATOUBOSS 11KW Hybrid Solar Inverter labeled components

Figura 3.2.2: Detallada view of the inverter's display, function buttons, and connection ports. Key components include the LCD display, status indicators, function buttons, AC input, main output, second output, BMS/RS485 communication port, RS232 communication port, solar module input, parallel connection port, battery input, and ON/OFF switch.

4. Instal·lació

Proper installation is critical for the inverter's performance and safety. Follow these guidelines carefully.

4.1 Site Selection and Mounting

  • Mount the inverter vertically on a solid surface capable of supporting its weight (approx. 19.19 kg).
  • Ensure adequate clearance around the inverter for proper airflow and heat dissipation. Maintain at least 20 cm clearance on all sides.
  • Avoid locations with high humidity, dust, corrosive gases, or direct exposure to water.
  • Interval de temperatura de funcionament: 0 °C a 55 °C.

4.2 Connexions de cablejat

All wiring must comply with local electrical codes and regulations. Use appropriate cable gauges for all connections.

Wiring and Technical Specifications Diagram

Figure 4.2.1: Comprehensive wiring diagram showing connections for PV modules, battery bank, utility grid, and AC loads. Recommended cable sizes and breaker ratings are indicated.

  • Connexió de la bateria: Connect the 48V battery bank to the battery input terminals. Ensure correct polarity. Recommended cable: 2 AWG (25mm²). Recommended fuse: 150A.
  • Connexió del panell fotovoltaic: Connect solar panels to the dual MPPT inputs (PV1 and PV2). Max PV array open circuit voltage: 500V DC. MPPT voltage range: 90-500V DC. Recommended cable: 10 AWG (6mm²).
  • AC Input (Utility/Generator): Connect the utility grid or a generator to the AC input. Rated input voltage: 220/230/240V AC. Max charge current: 160A. Recommended cable: 10 AWG (6mm²). Recommended breaker: 63A.
  • AC Output (Load): Connect your household or office loads to the AC output terminals. Output voltage: 220/230/240V AC ±5%. Rated output power: 11000W. Recommended cable: 10 AWG (6mm²). Recommended breaker: 63A.
  • Connexió paral·lel: For parallel operation, connect up to 9 inverters using the dedicated parallel communication ports. Refer to Figure 4.2.2 for examples.
Parallel and Three-Phase Wiring Examples

Figura 4.2.2: Examples of parallel connection for single-phase systems and three-phase electrical input/output wiring. A minimum of three inverters is required for three-phase operation.

5. Funcionament

This section details the operational aspects of your DATOUBOSS Hybrid Solar Inverter.

5.1 Pantalla LCD i botons de funció

The LCD display provides real-time system status and allows for configuration of various settings. The function buttons (ESC, UP, DOWN, ENTER) are used to navigate menus and adjust parameters.

Interfície de pantalla LCD

Figure 5.1.1: Close-up of the inverter's LCD display, showing input/output status, battery level, and power flow.

5.2 Modes de funcionament

The inverter offers flexible charging and output modes to suit different energy management needs.

Charging and Output Modes Diagram

Figure 5.2.1: Illustration of the four charging modes (Solar Priority, Solar Only, Utility Priority, Solar Hybrid & Utility) and three output modes (Solar Priority (SUB), Utility Priority (USB), Battery Priority (SBU)).

  • Modes de càrrega:
    • Prioritat solar: Solar energy is prioritized for charging the battery. If solar is insufficient, utility power is used.
    • Només solar: Only solar energy is used to charge the battery.
    • Prioritat d'utilitat: Utility power is prioritized for charging the battery. Solar energy is used if utility is unavailable.
    • Solar Hybrid & Utility: Both solar and utility power can charge the battery simultaneously.
  • Modes de sortida:
    • Solar Priority (SUB): Loads are primarily powered by solar, then battery, then utility.
    • Utility Priority (USB): Loads are primarily powered by utility, then solar, then battery.
    • Battery Priority (SBU): Loads are primarily powered by battery, then solar, then utility.

5.3 Battery-less Operation

The inverter supports operation without a connected battery, powering loads directly from PV generation or the utility grid. This feature is ideal for grid-tied systems where battery backup is not required.

Nota important: When multiple inverters are connected in parallel, a battery must be connected, and the battery-less operation function cannot be utilized.

6. Manteniment

Un manteniment regular garanteix la longevitat i el rendiment òptim del vostre inversor.

  • Neteja: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Comprovació de connexions: Annually inspect all wiring connections for tightness and signs of corrosion. Re-tighten if necessary.
  • Control ambiental: Assegureu-vos que l'entorn d'instal·lació es mantingui dins dels rangs de temperatura i humitat especificats.
  • Actualitzacions de firmware: Comproveu el del fabricant website for any available firmware updates. Follow instructions carefully if performing an update.

7. Solució De Problemes

Aquesta secció ofereix solucions per a problemes comuns que podeu trobar.

ProblemaCausa possibleSolució
L'inversor no s'encénNo DC input from battery/PV; AC input disconnected; ON/OFF switch off.Check battery and PV connections; ensure AC input is present; turn ON/OFF switch to ON.
Sense sortida de CAOverload; short circuit; battery low; inverter fault.Reduce load; check for short circuits; charge battery; check LCD for error codes.
La bateria no es carregaPV input too low; utility grid unavailable (if utility priority); charge settings incorrect.Check PV array for shading/damage; verify utility connection; adjust charge settings via LCD.
Alarma de sobretemperaturaInsufficient ventilation; ambient temperature too high; fan malfunction.Ensure proper airflow; move inverter to cooler location; contact support if fans are not working.

For issues not listed here or if problems persist, please contact DATOUBOSS customer support.

8. Especificacions

Detailed technical specifications for the DATOUBOSS 11KW Hybrid Solar Inverter.

ParàmetreValor
Número de model48V 11000W
Potència nominal11000W
Volum d’entrada nominaltage220/230/240V AC
Vol. De sortidatage220/230/240V AC ±5%
Màx. Circuit obert de matriu fotovoltaica Voltage500V DC
Corrent de càrrega fotovoltaica màxim150A
Max. Utility Charge Current120A
Max. Total Charge Current160A
MPPT PV Array Voltage Rang90 ~ 500 V CC
Màx. Eficiència de conversióFins al 98%
Dimensions del producte70.8 x 57 x 24.1 cm
Pes del producte19.19 quilos

9. Garantia i Suport

DATOUBOSS provides a 24-month warranty for this product, covering manufacturing defects and malfunctions under normal use conditions.

  • Període de garantia: 24 mesos des de la data de compra.
  • Política de devolució: 30 days unconditional return guarantee.
  • Atenció al client: For technical assistance, warranty claims, or any inquiries, please contact DATOUBOSS customer support through the retailer's platform or the official DATOUBOSS weblloc.

Si us plau, conserveu el comprovant de compra per validar la garantia.

© 2024 DATOUBOSS. All rights reserved.

Documents relacionats - 48V 11000W

Preview DATOUBOSS DT2430 Solar Hybrid Inverter - Important Usage Instructions
Essential safety and usage guidelines for the DATOUBOSS DT2430 Solar Hybrid Inverter, including proper handling and operation based on detailed online introductions.
Preview DATOUBOSS DT4855U 5500W Off-Grid Hybrid Solar Inverter User Manual
Comprehensive user manual for the DATOUBOSS DT4855U 5500W Off-Grid Hybrid Solar Inverter. Includes safety instructions, fault code definitions, commissioning steps for parallel systems, and LCD configuration settings.
Preview DATOUBOSS 4.2KVA/7.0KVA Wechselrichter/Ladegerät Benutzerhandbuch
Umfassendes Benutzerhandbuch für den DATOUBOSS 4.2KVA/7.0KVA Wechselrichter/Ladegerät, das Installation, Betrieb, Spezifikationen und Fehlerbehebung für Hybrid-Stromsysteme beschreibt.
Preview Manual d'usuari de l'inversor solar híbrid DATOUBOSS
Comprehensive user manual for the DATOUBOSS Hybrid Solar Inverter series, detailing installation, operation, safety guidelines, troubleshooting, and technical specifications. Supports parallel operation, grid-tie, and off-grid functionality for various models.
Preview Manual de l'inversor d'ona sinusoidal pura - Especificacions i guia de DATOUBOSS
Manual complet per a l'inversor d'ona sinusoidal pura DATOUBOSS, que detalla les especificacions, les funcions de protecció, els estats de la pantalla, el funcionament del control remot i les pautes d'instal·lació.
Preview DATOUBOSS Hybrid Solar Inverter User Manual (DT1220SQ, DT2436SQ, DT4862SQ, DT4811SQ)
Comprehensive user manual for DATOUBOSS Hybrid Solar Inverters. Includes installation, operation, settings, troubleshooting, and technical specifications for models DT1220SQ, DT2436SQ, DT4862SQ, and DT4811SQ.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.