1. Introducció
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the WVCLTVJA Solar Micro Inverter. This device converts direct current (DC) electricity generated by solar photovoltaic (PV) panels into alternating current (AC) electricity suitable for use in a grid-tied system. It features Maximum Power Point Tracking (MPPT) technology to optimize energy harvest from your solar array.
2. Informació de seguretat
WARNING! DANGER! Please read all safety instructions carefully before installation or operation to prevent injury or damage to equipment.
- Read this user manual completely before operating this equipment. Failure to do so can result in serious injury, property damage, and/or electrical shock.
- Use photovoltaic panels (PV) ONLY to connect to the inverter.
- DO NOT exceed the PV panel(s) voltage over the inverter's maximum input voltage.
- DO NOT exceed the PV panel(s) power over the inverter's maximum input power.
- DC voltage sources are passed through this equipment. Each circuit must be individually disconnected before servicing.
- DO NOT remove the lid. Servicing must be performed by qualified service personnel.
- When the PV array is exposed to light, it generates DC voltage. Install the inverter away from direct sunlight and direct rain exposure.

Figura 2.1: A baix view of the micro inverter, highlighting safety warnings and the status indicator light.
3. Producte acabatview
The WVCLTVJA Solar Micro Inverter is designed for direct connection to individual solar panels, maximizing energy conversion efficiency. It features robust construction and clear connection points for easy integration into your solar power system.
3.1 Components i connexions
- DC Input (PV): MC4 connectors for connecting to solar panels.
- Sortida de CA: Cable for connecting to the electrical grid.
- Indicador d'estat: LED light to display operational status.
- Suports de muntatge: Integrated for secure installation.

Figura 3.1: superior view of the micro inverter showing the DC input connectors and the AC output cable.

Figura 3.2: Detallada view of the DC+ and DC- input terminals and the AC output connection.

Figura 3.3: Angle view illustrating the integrated mounting brackets for installation.
4. Configuració i instal·lació
Proper installation is crucial for the safe and efficient operation of your micro inverter. Ensure all local electrical codes and regulations are followed. Installation should be performed by qualified personnel.
4.1 Muntatge de l'inversor
- Select a suitable mounting location, preferably under the solar panel, to protect it from direct sunlight and rain. Ensure adequate ventilation.
- Secure the inverter to the mounting structure using appropriate fasteners through the integrated mounting brackets.
4.2 DC Connection (Solar Panels)
- Connect the positive (+) and negative (-) cables from your solar panel to the corresponding DC+ and DC- MC4 input connectors on the micro inverter.
- Ensure the connections are secure and properly seated. Verify that the solar panel's voltage and power are within the inverter's specifications.
4.3 AC Connection (Grid)
- Connect the AC output cable from the micro inverter to your electrical grid system. This typically involves connecting to a dedicated circuit breaker in your electrical panel.
- Ensure all AC wiring is correctly terminated and insulated according to electrical standards.
4.4 Posada a terra
Ensure the inverter is properly grounded according to local electrical codes. This is a critical safety measure.
5. Funcionament
Once installed, the micro inverter operates automatically. When solar panels receive sufficient sunlight, the inverter will begin converting DC power to AC power and feeding it into the grid.
5.1 Encès
- After all connections (DC and AC) are securely made, turn on the AC circuit breaker connected to the inverter.
- L'inversor realitzarà una autoprova i després començarà a funcionar.
5.2 Indicador d'estat
The LED status indicator on the inverter provides information about its operational state:
- Verd sòlid: Normal operation, generating power.
- Verd intermitent: Initializing or waiting for sufficient PV power.
- Vermell sòlid: Fault or error condition. Refer to the troubleshooting section.
- Sense llum: No hi ha alimentació a l'inversor.
6. Manteniment
The WVCLTVJA Solar Micro Inverter requires minimal maintenance. Regular checks can help ensure optimal performance and longevity.
- Inspecció visual: Periodically inspect the inverter and all cables for any signs of damage, corrosion, or loose connections.
- Neteja: Keep the inverter's exterior clean and free from dust or debris. Use a soft, dry cloth. Do not use harsh chemicals or abrasive materials. Ensure ventilation fins are not blocked.
- Verificació professional: It is recommended to have a qualified electrician inspect your solar system periodically.
WARNING: Before performing any maintenance, ensure the inverter is disconnected from both the DC (solar panels) and AC (grid) power sources.
7. Solució De Problemes
This section provides solutions for common issues you might encounter with your micro inverter.
| Problema | Causa possible | Solució |
|---|---|---|
| Inverter not producing power / No status light | No AC power from grid; No DC power from PV; Loose connections. | Check AC breaker; Verify PV panel connections and sunlight; Inspect all wiring. |
| La llum d'estat és de color vermell continu | Internal fault; Over/under voltage; Over/under frequency. | Disconnect AC and DC power, wait 5 minutes, then reconnect. If error persists, contact support. |
| Sortida de baixa potència | Insufficient sunlight; Dirty PV panels; Shading; PV panel degradation. | Ensure panels are clean and free from shading; Check weather conditions. |
| Inverter frequently disconnects | Grid instability; Overheating. | Comproveu la graella voltage/frequency stability; Ensure adequate ventilation around the inverter. |
Si trobeu problemes que no figuren aquí o si les solucions no resolen el problema, poseu-vos en contacte amb l'atenció al client.
8. Especificacions
The WVCLTVJA Solar Micro Inverter is available in several wattage models. The specifications below detail the input and output characteristics for each variant.
8.1 GMI 260 Model Specifications
| Dades d'entrada (DC, PV) | |
|---|---|
| Nombre d'entrada Connector MC4 | 1 conjunt |
| MPPT Voltage Rang | 24V-40V |
| Operació Voltage Rang | 18V-50V |
| Volum d'entrada màximtage | 50 V |
| Startup Voltage | 18 V |
| Potència d'entrada màxima | 260W |
| Corrent d'entrada màxima | 10.4A |
| Dades de sortida (AC) | |
| Tipus de quadrícula monofàsica | 120V / 230V |
| Potència de sortida nominal | 250W |
| Potència de sortida màxima | 260W |
| Rated Output Current (120V/230V) | 2.08A/1.08A |
| Vol. De sortida nominaltage | 120 V AC / 230 V AC |
| Vol. de sortida per defectetage Range (120V/230V) | 80V-160V / 180V-280V |
| Freqüència de sortida nominal | 50Hz / 60Hz |
| Default Output Frequency Range (50Hz/60Hz) | 47.5Hz-52.5Hz / 57.5Hz-62.5Hz |
| Factor de potència | >0.99 <5% |
8.2 GMI 300 Model Specifications
| Dades d'entrada (DC, PV) | |
|---|---|
| Nombre d'entrada Connector MC4 | 1 conjunt |
| MPPT Voltage Rang | 24V-40V |
| Operació Voltage Rang | 18V-50V |
| Volum d'entrada màximtage | 50 V |
| Startup Voltage | 18 V |
| Potència d'entrada màxima | 300W |
| Corrent d'entrada màxima | 12A |
| Dades de sortida (AC) | |
| Tipus de quadrícula monofàsica | 120V / 230V |
| Potència de sortida nominal | 280W |
| Potència de sortida màxima | 300W |
| Rated Output Current (120V/230V) | 2.33A/1.21A |
| Vol. De sortida nominaltage | 120 V AC / 230 V AC |
| Vol. de sortida per defectetage Range (120V/230V) | 80V-160V / 180V-280V |
| Freqüència de sortida nominal | 50Hz / 60Hz |
| Default Output Frequency Range (50Hz/60Hz) | 47.5Hz-52.5Hz / 57.5Hz-62.5Hz |
| Factor de potència | >0.99 <5% |
8.3 GMI 350 Model Specifications
| Dades d'entrada (DC, PV) | |
|---|---|
| Nombre d'entrada Connector MC4 | 1 conjunt |
| MPPT Voltage Rang | 24V-40V |
| Operació Voltage Rang | 18V-50V |
| Volum d'entrada màximtage | 50 V |
| Startup Voltage | 18 V |
| Potència d'entrada màxima | 350W |
| Corrent d'entrada màxima | 14A |
| Dades de sortida (AC) | |
| Tipus de quadrícula monofàsica | 120V / 230V |
| Potència de sortida nominal | 320W |
| Potència de sortida màxima | 350W |
| Rated Output Current (120V/230V) | 2.67A / 1.39A (Estimated based on power) |
| Vol. De sortida nominaltage | 120 V AC / 230 V AC |
| Vol. de sortida per defectetage Range (120V/230V) | 80V-160V / 180V-280V |
| Freqüència de sortida nominal | 50Hz / 60Hz |
| Default Output Frequency Range (50Hz/60Hz) | 47.5Hz-52.5Hz / 57.5Hz-62.5Hz |
| Factor de potència | >0.99 <5% |
8.4 General Product Specifications
- Pes de l'article: 1.76 unces
- Dimensions del paquet: 1.18 x 0.79 x 0.39 polzades
- Fabricant: WVCLTVJA
- Muntatge requerit: No
9. Garantia i Suport
For warranty information and technical support, please refer to the product packaging or contact WVCLTVJA customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.