Jesverty SPS-3010 & JDS210

Jesverty DC Power Supply Variable & Digital Oscilloscope User Manual

Models: SPS-3010 (DC Power Supply) & JDS210 (Digital Oscilloscope)

1. Introducció

This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your Jesverty DC Power Supply (SPS-3010) and Digital Oscilloscope (JDS210). Please read this manual thoroughly before using the devices to ensure proper functionality and to prevent damage or injury.

Jesverty DC Power Supply and Digital Oscilloscope combined

Figure 1.1: Jesverty DC Power Supply SPS-3010 and Digital Oscilloscope JDS210.

2. Instruccions de seguretat

Always observe the following safety precautions to prevent electric shock, injury, or damage to the devices:

  • Assegureu-vos que la font d'alimentació voltage coincideix amb la xarxa local voltage abans de connectar.
  • Do not operate the devices in wet or damp condicions.
  • No obriu la c.asing of the devices. Refer all servicing to qualified personnel.
  • Assegureu-vos que hi hagi una ventilació adequada; no obstruïu les reixetes de refrigeració.
  • Disconnect power before making or breaking connections to the output terminals.
  • Use only specified probes and accessories with the oscilloscope.
  • Be aware of the maximum input voltage ratings for the oscilloscope channels.
Jesverty DC Power Supply with internal protection features highlighted

Figure 2.1: The power supply features multiple protection mechanisms including Short Circuit, Leakage, Thermal, Over Voltage, and Overload Protection to ensure safety and extend product life.

3. Producte acabatview i Components

3.1 DC Power Supply (SPS-3010)

The Jesverty SPS-3010 is a variable DC power supply offering adjustable voltage and current output. It features a 4-digit LED display for real-time monitoring of V/A/W.

Component names of the Jesverty DC Power Supply SPS-3010

Figure 3.1: Front and Rear Panel Components of the SPS-3010 DC Power Supply.

  1. Voltage Visualització
  2. Pantalla actual
  3. Pantalla de potència
  4. Indicador de mode CV (Volum constant)tage)
  5. Indicador de mode CC (corrent constant)
  6. VoltagManeta e (Ajust aproximat)
  7. Botó de corrent (ajust aproximat)
  8. Voltagbotó e (ajust fi)
  9. Botó de corrent (ajust fi)
  10. Port de càrrega USB (5V/2A)
  11. Terminal de sortida + (vermell)
  12. Terminal de connexió a terra (verd)
  13. Terminal de sortida - (Negre)
  14. Interruptor d'alimentació
  15. Ventilador de refrigeració
  16. Entrada d’alimentació de CA.
  17. Caixa de fusibles (fusible de recanvi a l'interior)

3.2 Digital Oscilloscope (JDS210)

The Jesverty JDS210 is a 100MHz dual-channel digital oscilloscope designed for precise waveform analysis.

Davant view of the Jesverty JDS210 Digital Oscilloscope

Figure 3.2: Front Panel of the JDS210 Digital Oscilloscope.

Els controls clau inclouen:

  • Visualització: 7-inch TFT LCD (800x480 resolution) for waveform visualization.
  • Controls horitzontals: Scale and Position knobs for time base adjustment.
  • Controls verticals: Scale and Position knobs for voltage per division adjustment for each channel (CH1, CH2).
  • Controls de disparador: For stabilizing repetitive waveforms.
  • Botons de funció: Auto, Utility, Measure, Acquire, Cursor, Copy, Single, Run/Stop, Math, Menu, Force.
  • Canals d'entrada: CH1 and CH2 BNC connectors.
  • Port USB: For data storage and transfer.
Enrere view of the Jesverty JDS210 Digital Oscilloscope

Figure 3.3: Rear Panel of the JDS210 Digital Oscilloscope, showing ventilation and power input.

4. Configuració

4.1 DC Power Supply (SPS-3010) Setup

  1. Col·locació: Place the power supply on a stable, level surface with adequate ventilation. Ensure cooling fan vents are not obstructed.
  2. Connexió d'alimentació: Connect the supplied AC power cord to the AC Power Inlet (16) on the rear panel and plug it into a grounded wall outlet.
  3. Connexions de sortida: Connect your load to the Output Terminals: Red (+) to positive, Black (-) to negative. The Green (GND) terminal is for chassis ground.
  4. Encesa inicial: Assegureu-vos Voltage and Current knobs are set to minimum before turning on the Power Switch (14).

4.2 Digital Oscilloscope (JDS210) Setup

  1. Col·locació: Place the oscilloscope on a stable, flat surface.
  2. Connexió d'alimentació: Connect the supplied power adapter to the oscilloscope's power input and then to a power outlet.
  3. Connexió de la sonda: Connect the oscilloscope probes to the CH1 or CH2 BNC input connectors. Ensure the probe's attenuation setting (e.g., 1X, 10X) matches the oscilloscope's probe setting. The oscilloscope supports 1X/10X/100X/1000X probes.
  4. Compensació de la sonda: Before taking measurements, compensate your probes. Connect the probe to CH1 and the probe tip to the probe compensation output (usually a small terminal near the BNC inputs). Adjust the probe until a perfect square wave is displayed.

5. Instruccions de funcionament

5.1 DC Power Supply (SPS-3010) Operation

  1. Encès: Press the Power Switch (14). The LED display will illuminate.
  2. Configuració Voltage: Utilitzeu el voltage Coarse (6) and Fine (8) knobs to set the desired output voltage. El voltage Display (1) shows the current setting.
  3. Setting Current Limit: Use the Current Coarse (7) and Fine (9) knobs to set the maximum output current. This acts as a current limit to protect your circuit. The Current Display (2) shows the current limit.
  4. Vol. Constanttage (C.V.) and Constant Current (C.C.) Modes:
    • When the load resistance is high, the power supply operates in C.V. mode (Constant Voltage), indicated by the C.V. Mode Indicator (4). The output voltage remains constant at the set value.
    • When the load resistance is low, causing the current to reach the set limit, the power supply automatically switches to C.C. mode (Constant Current), indicated by the C.C. Mode Indicator (5). The output current remains constant at the set limit, and the voltage gotes.
  5. Funció de càrrega USB: The 5V/2A USB Charging Port (10) can be used to charge compatible devices. This port provides a fixed 5V output at up to 2A, independent of the main output settings.
Jesverty DC Power Supply with a phone charging via its USB port

Figure 5.1: The SPS-3010 supports 5V/2A USB charging for various devices.

5.2 Digital Oscilloscope (JDS210) Operation

  1. Encès/apagat: Press the power button on the front panel to turn the oscilloscope on or off.
  2. Classificació automàtica: Press the 'Auto' button for automatic setup of vertical, horizontal, and trigger settings to display a stable waveform.
  3. Selecció de canals: Use the CH1 and CH2 buttons to enable or disable channels.
  4. Vertical Scaling (Voltage): Use the 'Scale' knob for each channel (V/Div) to adjust the vertical sensitivity. The 'Position' knob moves the waveform vertically.
  5. Horizontal Scaling (Time): Use the 'Scale' knob (s/Div) to adjust the time base. The 'Position' knob moves the waveform horizontally.
  6. Activació: Adjust the 'Trigger' level knob to stabilize the waveform. The trigger mode can be set via the menu.
  7. Mides: Use the 'Measure' button to access automatic measurements (e.g., Vpp, Vrms, Frequency). Use the 'Cursor' button to enable manual cursors for precise voltage (ΔV) and time (ΔT) measurements.
  8. Emmagatzematge USB: Connect a USB drive to the USB port to save waveform data or screenshots. Use the 'Copy' button or menu options to transfer data.
En angle view of the Jesverty JDS210 Digital Oscilloscope in operation

Figure 5.2: The JDS210 oscilloscope provides a clear display for waveform analysis.

6. Manteniment

  • Neteja: Disconnect power before cleaning. Use a soft, dry cloth to clean the exterior. Do not use abrasive cleaners or solvents.
  • Ventilació: Regularly check that the cooling vents on both devices are clear of dust and debris. Use compressed air if necessary to clear dust from the fan and vents.
  • Emmagatzematge: Guardeu els dispositius en un lloc fresc i sec, allunyat de la llum solar directa i de temperatures extremes.
  • Fuse Replacement (SPS-3010): If the power supply does not turn on, check the fuse located in the Fuse Box (17) on the rear panel. Replace with a fuse of the same type and rating if blown. A spare fuse is typically included inside the fuse box.

7. Solució De Problemes

If you encounter issues with your Jesverty devices, refer to the following common problems and solutions:

  • Sense energia:
    • Check if the power cord is securely connected to the device and the wall outlet.
    • Verifiqueu que la presa de corrent tingui corrent.
    • For SPS-3010, check and replace the fuse if necessary (refer to Maintenance section).
  • SPS-3010 Output Voltage/Current Not Stable or Zero:
    • Ensure output terminals are correctly connected to the load.
    • Check if the current limit is set too low for the load. Increase the current limit using the current knobs.
    • If in C.C. mode, the voltage will drop to maintain the set current. This is normal operation.
  • JDS210 No Waveform or Unstable Waveform:
    • Ensure probes are correctly connected to the oscilloscope and the circuit under test.
    • Comproveu la compensació de la sonda.
    • Adjust vertical (V/Div) and horizontal (s/Div) scales.
    • Adjust the trigger level or use the 'Auto' button.
    • Verify the input signal is within the oscilloscope's measurement range.
  • Problemes de visualització:
    • If the display is blank or distorted, power cycle the device.
    • Assegureu-vos una ventilació adequada per evitar el sobreescalfament.

If problems persist, contact Jesverty customer support for assistance.

8. Especificacions

8.1 DC Power Supply (SPS-3010)

ParàmetreValor
Vol. De sortidatage0-30V (ajustable)
Corrent de sortida0-10A (Ajustable)
Potència màxima300 watts
Resolució de pantalla (Volum)tage)0.01 V
Resolució de pantalla (actual)0.001A
Resolució de pantalla (potència)0.1W
Sortida del port USB5V/2A

8.2 Digital Oscilloscope (JDS210)

ParàmetreValor
Ample de banda100 MHz
Canals2
Temps real SampTarifa ling500 MS/s
Interval de base de temps2 ns/Div to 1000 s/Div
Vertical Scaling20 mV/Div to 5 V/Div
Mostra7-inch TFT LCD (800x480 resolution)
Waveform StorageUp to 16 waveform sets
SampLing Points10K+ per acquisition
Compatibilitat de la sonda1X/10X/100X/1000X

9. Garantia i Suport

Jesverty products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your product packaging or visit the official Jesverty website. Please have your model number (SPS-3010 or JDS210) and purchase details ready when contacting support.

© 2025 Jesverty. Tots els drets reservats.