Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the GODIYMODULES Load Cell Sensor Transmitter Amplifier Module. This module is designed to convert signals from various strain sensors (such as weighing, tension, and pressure sensors) into standard 0-5V, 0-10V, or 4-20mA output signals. Please read this manual thoroughly before use to ensure proper functionality and safety.
Característiques del producte
- Utilizes a specialized instrumentation load cell amplifying chip for strong performance.
- Features a high-precision operational amplifier circuit, ensuring high accuracy and stability.
- Incorporates inductors and capacitors for power supply filtering, effectively reducing ripple interference.
- Equipped with reverse connection protection and surge protection for the power supply.
- Compatible with various strain sensors, including those for weighing, tension, pressure, and torque applications.
- Includes a power supply indicator and an output current strength indicator for easy monitoring.
- Supports multiple output signals: 0-5V, 0-10V, 4-20mA, or 0-20mA.
- Vol. Operatiutage range: DC 12-24V.
Configuració
Follow these steps for proper installation and wiring of the Load Cell Sensor Transmitter AmpMòdul lifier.
Esquema de cablejat

Figura 1: Diagrama de cablejat. This diagram illustrates the connections for the sensor terminal, power supply, and output signals. The left terminals are for sensor input (+S, -S, +E, GND), and the right terminals are for power (Power Positive, Power Negative) and output (0-5V, 0-10V, 4-20mA).
- Sensor Terminal: Define wiring according to the sensor's sequence. For example, if the sensor's red wire is excitation positive, connect it to the transmitter's excitation positive (E+).
- Font d'alimentació: Connect the positive terminal of the 12-24V DC power supply to "Power Positive" and the negative terminal to "Power Negative".
- Senyals de sortida: The 0-5V, 0-10V, and 4-20mA outputs share a common negative connection with the power supply negative.
Definició de la interfície

Figure 2: Module Overview. This image shows the general layout of the module with its input and output terminals.
| Tipus de senyal | Identificació del cablejat | Definició del cablejat |
|---|---|---|
| Input Signal (Sensor) | +S | Signal Positive |
| -S | Signal Negative | |
| +E | Excitation Power Supply Positive | |
| GND | Excitation Power Supply Negative | |
| Output Signal & Power | VIN | Font d'alimentació positiva |
| GND | Negatiu de la font d'alimentació | |
| FORA | Sortida 4-20mA | |
| 0-5V | Sortida 0-5V | |
| 0-10V | Sortida 0-10V |
Nota: The output excitation power supply voltage of the module is 12V. The current and voltage outputs are relative to GND. On the front of the board, the left 4 terminals connect to the sensor, and the right 5 terminals are for output and power supply.
Instruccions de funcionament
After successful wiring, the module is ready for operation. Ensure all connections are secure before applying power.
- Encès: Apply DC 12-24V power to the VIN and GND terminals. The power supply indicator LED should illuminate.
- Connexió del sensor: Connect your load cell or strain sensor to the +S, -S, +E, and GND terminals on the left side of the module according to the sensor's specifications and the wiring diagram.
- Selecció de sortida: The module provides simultaneous 0-5V, 0-10V, and 4-20mA outputs. Select the appropriate output for your receiving device (e.g., PLC, microcontroller, display).
- Calibration (if necessary): Depending on the specific load cell and application, calibration may be required to accurately map the sensor's output to the desired voltage/current range. Refer to your load cell's documentation for calibration procedures. The potentiometers on the module may be used for fine-tuning the output range, but precise calibration typically involves external equipment.
- Seguiment: Observe the output current strength indicator and the readings on your connected device to ensure proper operation.
Esquema d'aplicació

Figure 3: Application Schematic. This schematic demonstrates typical applications, showing the module interfacing with different types of load cells (e.g., S-type, button-type, bar-type), a power supply, and output devices such as a PLC (Programmable Logic Controller) or a microcontroller.
Manteniment
The Load Cell Sensor Transmitter Amplifier Module is designed for reliable operation with minimal maintenance. Adhere to the following guidelines:
- Condicions ambientals: Operate the module within its specified temperature range (up to 80 °C) and in a dry environment to prevent moisture damage.
- Neteja: If necessary, gently clean the module with a soft, dry cloth. Avoid using liquids or abrasive cleaners.
- Comprovacions de connexió: Inspeccioneu periòdicament totes les connexions del cablejat per assegurar-vos que estiguin ben fixades i sense corrosió.
- Font d'alimentació: Assegureu-vos que la font d'alimentació voltage remains within the DC 12-24V range to prevent damage.
Resolució de problemes
If you encounter issues with the module, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| Sense llum indicadora d'alimentació | Sense font d'alimentació, volum incorrectetage, reverse polarity, or faulty connection. | Check power supply (DC 12-24V), ensure correct polarity, and verify all power connections. |
| No output signal or incorrect output | Incorrect sensor wiring, faulty sensor, incorrect output terminal selection, or module malfunction. | Verify sensor wiring according to the diagram. Test the sensor independently. Ensure the correct output terminal (0-5V, 0-10V, 4-20mA) is connected to your receiving device. |
| Unstable or noisy output | Power supply ripple, electromagnetic interference, or loose connections. | Ensure a stable and clean power supply. Check for nearby sources of electromagnetic interference. Secure all wiring connections. |
| Output does not match expected range | Module requires calibration or sensor is not properly calibrated. | Perform calibration as per sensor and application requirements. Adjust potentiometers on the module if necessary for fine-tuning. |
Especificacions
| Paràmetre | Valor |
|---|---|
| Marca | MÒDULS DE GODIY |
| Número de model | Y-S65-001 |
| Voltage | DC 12-24V |
| Opcions de senyal de sortida | 0-5V, 0-10V, 4-20mA, 0-20mA |
| Valoració actual | 20 milamps (màx.) |
| Tipus de sortida | Electrical signal (Push-Pull) |
| Classificació de temperatura superior | 80 °C |
| Usos específics | Weighing, tension pressure, torque sensors |
| Components inclosos | 1PCS Load Cell Sensor Transmitter AmpMòdul més viu |
Què hi ha a la caixa
- 1 x GODIYMODULES Load Cell Sensor Transmitter Amplifier Module (Model: Y-S65-001)
Garantia i Suport