ECOELER YM2112

ECOELER Motion Sensor Light Switch

Model: YM2112 - Instruction Manual

1. Introducció

The ECOELER Motion Sensor Light Switch (Model YM2112) provides automated lighting control using Passive Infrared (PIR) motion detection. This device is designed for single-pole applications and requires a neutral wire for installation. It offers adjustable settings for sensitivity, ambient light detection, and time delay, allowing customization for various indoor environments such as bathrooms, laundry rooms, closets, and garages.

ECOELER Motion Sensor Light Switch with faceplate.

Figure 1: ECOELER Motion Sensor Light Switch with faceplate.

2. Informació de seguretat

  • ADVERTIMENT: Per evitar incendis, descàrregues elèctrices o la mort, desconnecteu l'alimentació a l'interruptor o a la caixa de fusibles i comproveu que estigui apagada abans de connectar el cablejat.
  • Installation must be performed by a qualified electrician or a person with a thorough understanding of electrical wiring.
  • This device is for single-pole applications only. Do not use in 3-way or multi-way circuits.
  • A neutral wire is required for operation. Ensure your electrical box has a neutral wire (typically white) before installation.
  • No supereu la potència màximatage ratings: 150W for LED/CFL, 300W for Incandescent/Halogen.
  • Utilitzeu només filferro de coure.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • Motion Sensor Light Switch (YM2112)
  • Placa de paret
  • Instruccions d'instal·lació
  • Cargols de muntatge (4 peces)
ECOELER Motion Sensor Light Switch, wall plate, and screws.

Figure 2: Included components: Motion Sensor Light Switch, wall plate, and mounting screws.

4. Característiques

  • Control mans lliures: Automatically activates lighting upon motion detection.
  • Selecció del mode: Choose between Occupancy (OCC) and Vacancy (VAC) modes.
  • Configuració ajustable: Customizable time delay (15s to 30min), sensitivity (20% to 100%), and ambient light sensing (dark to day).
  • Àmplia compatibilitat: Supports LED/CFL (up to 150W) and Incandescent/Halogen (up to 300W) bulbs.
  • Single Pole Control: Designed for single-pole circuits only.
  • Ampli rang de detecció: 180° detection angle with a maximum range of 26 feet (8 meters).
  • Construcció duradora: Features a tough thermoplastic housing for impact and scratch resistance.

5. Instal·lació

5.1 Llista de comprovació prèvia a la instal·lació

  1. Assegureu-vos que l'alimentació estigui DESCONNECTADA a l'interruptor automàtic abans d'engegar.
  2. Confirm the presence of a neutral wire (typically white) in your electrical box. This switch requires a neutral wire.
  3. Verify that the circuit is a single-pole setup. This switch is not compatible with 3-way or multi-way circuits.

5.2 Instruccions de cablejat

Follow the wiring diagram carefully. If you are unsure about any steps, consult a qualified electrician.

  1. Apagueu l'alimentació a l'interruptor.
  2. Traieu la placa de paret existent i l'interruptor.
  3. Identify the wires: Hot (Black), Load (Red, or another color connected to the light), Neutral (White), and Ground (Green or bare copper).
  4. Connect the wires from the wall box to the corresponding terminals on the ECOELER Motion Sensor Light Switch as shown in the wiring diagram below.
  5. Secure the switch into the wall box with the provided screws.
  6. Fixeu la nova placa de paret.
  7. Resta l'alimentació al disjuntor.
  8. Allow a 30-second warm-up period after power is restored for the sensor to calibrate.
Wiring diagram for the ECOELER Motion Sensor Light Switch, showing connections for neutral, hot, load, and ground wires.

Figure 3: Wiring Diagram for Model YM2112.

Wiring Connections for YM2112 Series Switch
Circuit Box WireScrew on YM2112 Switch
Power wire (hot)Negre
Load to power light or fanOr
Green or non-insulated (copper) ground wireVerd
Neutral (required)Plata

Nota: There is a 30-second warm-up period after each power reset. During this time, the sensor may not respond immediately.

6. Funcionament

The ECOELER Motion Sensor Light Switch offers three primary operation modes: Occupancy (OCC), Vacancy (VAC), and OFF. These modes are selected using the internal switches located behind the faceplate.

Diagram illustrating Occupancy, Vacancy, and OFF modes for the ECOELER Motion Sensor Light Switch.

Figure 4: Operation Modes Diagram.

6.1 Occupancy (OCC) Mode

  • Funció: Automatic ON and Automatic OFF.
  • Comportament: The light automatically turns ON when motion is detected and automatically turns OFF after a set time delay when no motion is detected.
  • Ideal per a: High-traffic areas where hands-free operation is desired, such as bathrooms, laundry rooms, and closets.

6.2 Vacancy (VAC) Mode

  • Funció: Manual ON and Automatic OFF.
  • Comportament: The light must be manually turned ON by pressing the ON/OFF button. It will then automatically turn OFF after a set time delay when no motion is detected.
  • Ideal per a: Areas where you prefer to control when the light turns on, but still want the energy-saving benefit of automatic shut-off, such as offices or living rooms.

6.3 Mode OFF

  • Funció: Manual ON and Manual OFF.
  • Comportament: The light is controlled entirely manually by pressing the ON/OFF button. Motion detection is disabled for light activation, but the sensor may still detect motion (indicated by an LED flash) without triggering the light.
  • Ideal per a: Situations where automatic control is not desired, or for testing purposes.

7. Configuració personalitzable

The ECOELER Motion Sensor Light Switch features adjustable settings for optimal performance. These settings are accessed by carefully removing the faceplate to reveal the adjustment dials and switches.

ECOELER Motion Sensor Light Switch with cover removed, showing sensitivity, light level, and time delay adjustments.

Figura 5: Intern view of adjustable settings.

Primer pla view of the adjustable settings on the ECOELER Motion Sensor Light Switch, including sensitivity, light level, and time delay.

Figura 6: Detallada view of customizable settings.

7.1 Adjustable Sensitivity (SENSE)

  • Interval: Low (20%) to High (100%).
  • Funció: Controls how easily the sensor detects motion.
  • Ajust: Turn the 'SENSE' dial to increase or decrease the detection range and responsiveness. Higher sensitivity detects smaller movements or movements further away.

7.2 Adjustable Light Level (LIGHT)

  • Configuració: Day, Dim, Dark.
  • Funció: Determines the ambient light level at which the sensor will activate the lights.
  • Ajust: Select 'Day' for activation regardless of ambient light, 'Dim' for activation in low light conditions (evening), and 'Dark' for activation only in very low light (night).

7.3 Adjustable Time Delay (TIME)

  • Interval: 15 seconds, 1 minute, 5 minutes, 15 minutes, 30 minutes.
  • Funció: Sets how long the light remains ON after the last detected motion.
  • Ajust: Select the desired time delay using the 'TIME' dial.

8. Interval de detecció

The ECOELER Motion Sensor Light Switch utilizes Passive Infrared (PIR) technology to detect human body heat movement. It offers a wide detection area for effective coverage in various room layouts.

  • Angle de detecció: 180 graus.
  • Interval màxim: Up to 26 feet (approximately 8 meters) from the front, and up to 15 feet (approximately 4.5 meters) on the sides.
  • Col·locació: For optimal performance, install the switch in a location where its field of view is not obstructed by furniture, doors, or other objects.
Diagram showing the 180-degree motion detection range of the ECOELER Motion Sensor Light Switch.

Figure 7: Motion Detection Coverage Area.

9. Manteniment

The ECOELER Motion Sensor Light Switch requires minimal maintenance. Follow these guidelines to ensure proper function and longevity:

  • Neteja: Gently wipe the surface of the switch and sensor lens with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
  • Obstruccions: Ensure the sensor lens is free from dust, dirt, or any obstructions that could interfere with motion detection.
  • Comprovacions periòdiques: Periodically test the switch's functionality to ensure it is operating correctly in your chosen mode and settings.
  • Power Off for Service: Always turn off power at the circuit breaker before performing any maintenance that involves removing the wall plate or accessing internal components.

10. Solució De Problemes

If you experience issues with your ECOELER Motion Sensor Light Switch, refer to the following common problems and solutions:

Guia de resolució de problemes
ProblemaCausa possibleSolució
Light does not turn ON with motion.1. L'alimentació està apagada.
2. Cablejat incorrecte.
3. Sensor lens obstructed.
4. Sensibilitat establerta massa baixa.
5. Light level setting too high (e.g., 'Dark' in a bright room).
6. Switch is in VAC or OFF mode and not manually activated.
1. Comproveu l'interruptor.
2. Verify wiring connections (refer to Section 5.2). Ensure neutral wire is connected.
3. Clear any obstructions from the sensor lens.
4. Increase sensitivity setting (refer to Section 7.1).
5. Adjust light level setting (refer to Section 7.2).
6. Switch to OCC mode or manually activate in VAC mode.
Light turns ON too frequently or unexpectedly.1. Sensibilitat establerta massa alta.
2. Sensor detecting motion outside desired area (e.g., pets, drafts).
3. Switch is in OCC mode in a high-traffic area.
1. Decrease sensitivity setting (refer to Section 7.1).
2. Reposition the switch or adjust sensitivity to narrow detection.
3. Consider switching to VAC mode if manual activation is preferred.
Light turns OFF too quickly or stays ON too long.La configuració del retard de temps és incorrecta.Adjust the time delay setting to your preference (refer to Section 7.3).
Light flickers or does not work with certain bulbs.Incompatibility with bulb type or wattage superat.Ensure bulbs are within specified wattage limits (LED/CFL up to 150W, Incandescent/Halogen up to 300W). Try a different type of compatible bulb.
Switch does not respond after power restoration.Warm-up period not completed.Allow 30 seconds for the sensor to warm up and calibrate after power is restored.

11. Especificacions

Especificacions del producte
AtributDetall
Número de modelYM2112
Font d'alimentacióElèctric amb cable
Voltage120V CA, 60Hz
Max Load (LED/CFL)150W
Càrrega màxima (incandescent/halògena)300W
Tipus de muntatgeMuntatge de paret
Angle de detecció180 graus
Interval màxim26 peus (8 metres)
Temperatura de funcionamentDe 32 °F a 104 °F (de 0 °C a 40 °C)
Dimensions del producte (P x A x A)115D x 40W x 68H millimeters (4.53 x 1.57 x 2.68 inches)
Pes de l'article0.15 lliures (68 grams)
Fil neutreObligatori
País d'origenXina

12. Garantia

The ECOELER Motion Sensor Light Switch (Model YM2112) comes with a one-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or service, please contact ECOELER customer support.

13. Suport

For technical assistance, troubleshooting, or general inquiries regarding your ECOELER Motion Sensor Light Switch, please contact our support team:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.