Moonshan MS-RO-200G

Moonshan 200GPD RO Booster Pump (Model MS-RO-200G) Instruction Manual

For Reverse Osmosis Water Filtration Systems

1. Introducció

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of your Moonshan 200GPD Booster Pump, Model MS-RO-200G. This pump is designed to enhance the performance of Reverse Osmosis (RO) water filtration systems by increasing water pressure, ensuring optimal filtration efficiency and consistent water flow. Please read this manual thoroughly before installation and operation.

2. Informació de seguretat

  • Ensure the power supply matches the pump's specifications (24V DC adapter).
  • Do not operate the pump with damaged wiring or power adapter.
  • Mantingueu les connexions elèctriques seques i allunyades de l'aigua.
  • Desconnecteu l'alimentació abans de realitzar qualsevol procediment de manteniment o instal·lació.
  • This pump is designed for use with RO systems under 200 GPD. Using it with systems above this capacity is not recommended.
  • Assegureu-vos que totes les connexions estiguin ben fixades per evitar fuites.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents al paquet:

  • Moonshan 200GPD Booster Pump (Model MS-RO-200G)
  • Interruptor d'alta pressió
  • 1/4'' RO Water Tube (3.28 inches) x1
  • 3/8'' to 1/4'' Quick Connector (Pre-installed) x1
  • 3/8'' to 1/4'' Quick Connector-L Type x2
  • Connection Wire x1
  • 2.5mm T-shaped Flat Head Hex Wrench x1 (for pressure adjustment)
  • Adaptador de corrent de 24 V x1
Diagram showing all components included in the Moonshan 200GPD Booster Pump kit.

Figura 3.1: Included components of the Moonshan 200GPD Booster Pump kit.

4. Configuració i instal·lació

The Moonshan booster pump features a quick-connection design for straightforward installation. Follow these steps to integrate the pump into your RO system:

4.1 Sistema acabatview

Diagram illustrating the installation of the Moonshan booster pump and high-pressure switch within an under-sink RO system setup.

Figura 4.1: Typical installation diagram for the booster pump in an RO system.

4.2 Quick Connection Steps

  1. Connect AC Quick-Connect Terminal Cable: Attach the AC quick-connect terminal cable to the pump's power input.
  2. Connect 1/4" Quick Connectors: Utilize the provided 1/4" quick connectors to integrate the pump into your RO system's water lines. Ensure a secure fit to prevent leaks. The kit includes both 'I-shaped' and 'L-shaped' fittings for flexible installation.
  3. Install High-Pressure Switch: Connect the high-pressure switch into the RO system's permeate line (after the RO membrane but before the storage tank). This switch controls the pump's auto start/stop function based on tank pressure.
  4. Connecteu l'adaptador d'alimentació: Plug the 24V power adapter into a suitable electrical outlet.
Two images showing the quick connection process: one for the AC terminal cable and one for the 1/4 inch quick connector.

Figura 4.2: Quick-connect terminal cable and 1/4" quick connector installation.

4.3 Placement and Compatibility

  • Mount the pump in a stable, dry location, typically under the sink near your RO unit.
  • The pump is compatible with RO systems rated up to 200 GPD. It is not recommended for systems exceeding this capacity.
  • The pump is equipped with shock-absorbing rubber feet to reduce operational noise and vibration.
Close-up of the Moonshan booster pump with water flowing through clear tubes, indicating it's designed for RO systems under 200 GPD.

Figura 4.3: Pump compatibility and inlet pressure range.

5. Instruccions de funcionament

5.1 Funcionament automàtic

The integrated high-pressure switch enables automatic operation. The pump will:

  • Start Automatically: When the pressure in the RO storage tank drops (e.g., when water is drawn from the faucet), the pump will automatically turn on to supply pressurized water to the RO membrane.
  • Atura automàticament: When the RO storage tank reaches its full pressure capacity, the high-pressure switch will detect this and automatically turn off the pump, conserving energy and preventing over-pressurization.

5.2 Ajust de pressió

The working pressure of the pump can be adjusted to suit environmental conditions and specific RO system requirements. Use the provided 2.5mm T-shaped flat head hex wrench to adjust the pressure screw on the pump. This allows you to fine-tune the output pressure, typically boosting inlet pressure from 30-40 psi to a robust 60-80 psi.

A hand using a hex wrench to adjust a screw on the side of the booster pump, indicating adjustable working pressure.

Figura 5.1: Adjusting the working pressure with the hex wrench.

6. Manteniment

Regular maintenance ensures the longevity and optimal performance of your booster pump:

  • Inspeccionar si hi ha fuites: Periodically check all connections and tubing for any signs of leaks. Tighten connections as needed.
  • Exterior net: Keep the pump's exterior clean and free from dust or debris. Use a soft, damp drap per netejar.
  • Comproveu el cable d'alimentació: Ensure the power cord and adapter are free from damage. Replace immediately if any damage is observed.
  • Escolteu els sorolls inusuals: While the pump is designed for quiet operation (around 30dB), listen for any unusual or excessive noise, which could indicate an issue.

7. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves solucions:

ProblemaCausa possibleSolució
Low water flow or slow tank fillingInsufficient inlet pressure; Clogged filters; Incorrect pump pressure setting.Verify adequate inlet water pressure. Check and replace RO filters if necessary. Adjust pump working pressure using the hex wrench.
La bomba no s'encénNo power; Faulty high-pressure switch; Loose electrical connection.Check power adapter connection and outlet. Ensure all electrical connections are secure. Test or replace the high-pressure switch if it's not activating the pump.
La bomba funciona contínuamentFaulty high-pressure switch; System leak; Low tank pressure.Inspect for leaks in the RO system. Check the high-pressure switch for proper function. Ensure the RO tank is not damaged or losing pressure.
Fuites d'aigua de les connexionsLoose fittings; Damaged O-rings/seals; Incorrectly installed tubing.Ensure all quick-connect fittings are fully inserted and locked. Inspect O-rings and seals for damage and replace if necessary. Apply additional thread tape if needed for threaded connections.
Excessive wastewaterLow feed water pressure; Clogged flow restrictor; Damaged RO membrane.Ensure the booster pump is providing adequate pressure. Check the flow restrictor for blockages. Inspect and replace the RO membrane if it is old or damaged.

8. Especificacions

CaracterísticaEspecificació
MarcaMoonshan
Número de modelMS-RO-200G
MaterialPlàstic
Estil200 GPD
Dimensions del producte7.7 cm de llargada x 4 cm d'amplada x 3.6 cm d'alçada
Font d'alimentacióCorded Electric (24V DC Adapter)
Caudal màxim1.5 litres per minut
Alçada màxima d'elevació6.56 peus
Característiques especialsAdjustable Pressure, Auto Start/Stop Function
Pes de l'article5.74 lliures

9. Garantia i Suport

Moonshan products are manufactured to high-quality standards. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty details, duration, and to obtain support, please refer to the warranty card included with your product or contact Moonshan customer service directly. Please have your model number (MS-RO-200G) and purchase date available when contacting support.