Moonshan MS-DP

Moonshan RO Delivery Demand Pump with Pressurized Accumulator Tank

Model: MS-DP

1. Introducció

Thank you for choosing the Moonshan RO Delivery Demand Pump with Pressurized Accumulator Tank. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new water booster pump system. Please read this manual thoroughly before installation and keep it for future reference.

This system is designed to enhance water pressure for Reverse Osmosis (RO) filtration systems, particularly when low city water pressure is an issue or when RO-filtered water needs to be delivered to distant appliances like ice makers, refrigerators, or coffee machines.

Comparison of water flow before and after using the Moonshan RO Delivery Demand Pump, showing increased pressure.

Image 1.1: Visual comparison of water flow before and after pump installation, demonstrating improved water pressure.

2. Producte acabatview i Característiques

The Moonshan RO Delivery Demand Pump system is engineered for reliable and quiet performance, ensuring a consistent water supply from your RO system. Key features include:

  • On-Demand Water Delivery: The 110V diaphragm pump operates in demand or delivery mode, effectively compensating for low city water pressure and ensuring stable performance for RO filtration.
  • Auto On/Off Operation: A built-in pressure switch automatically activates the pump when water is demanded (0.7 GPM at 70 PSI) and shuts it off when pressure reaches 60 PSI, preventing overuse and extending system life.
  • Disseny de connexió ràpida: Features 1/4" OD push-in fittings for straightforward and easy installation.
  • Pressurized Accumulator Tank: A 1-liter pre-pressurized tank works in conjunction with the pump to reduce cycling, minimize noise (≤45dB), and dampen vibration. It stabilizes flow, reduces water hammer, and prolongs pump service life.
  • Vibration Control Kit: Includes anti-vibration rubber feet and pipe insulation tubing to further reduce noise and vibration during operation.
Primer pla view of the pressurized accumulator tank with specifications and benefits listed.

Image 2.1: The pressurized accumulator tank, highlighting its role in reducing pump cycling and noise.

Components of the vibration control kit, including pipe insulation tubing and rubber anti-vibration pads.

Image 2.2: The included vibration control kit components: pipe insulation tubing and rubber anti-vibration pads.

3. Informació de seguretat

Si us plau, observeu les següents precaucions de seguretat per evitar lesions i danys al producte:

  • Desconnecteu sempre l'alimentació abans de realitzar qualsevol servei o manteniment.
  • Ensure the pump is installed in a dry, well-ventilated area, protected from freezing temperatures and direct sunlight.
  • No feu funcionar la bomba amb líquids inflamables.
  • Verify all connections are secure and leak-free before operating the pump.
  • Use only with potable water.
  • Ensure the electrical supply matches the pump's voltage requisits (110V).

4. Contingut del paquet

Verifiqueu que tots els components siguin presents i no estiguin danyats:

  • RO Delivery/Demand Pump (110V)
  • Pressurized Accumulator Tank (1L)
  • 1/4" Quick Connection Fittings
  • Anti-Vibration Rubber Feet
  • Pipe Insulation Tubing
  • Manual d'instruccions

5. Especificacions

EspecificacióValor
MarcaMoonshan
Número de modelMS-DP
MaterialAcer inoxidable
EstilDiafragma
Dimensions del producte (L x A x A)9" x 4.72" x 3.94"
Pes de l'article8 lliures
Font d'alimentacióElèctric amb cable
Voltage110 Volts
Caudal màxim1 Gallon Per Minute (GPM)
Shut-off Pressure60 PSI
Operating Pressure (Demand)70 PSI
Accumulator Tank Capacity1 litre (aprox. 25 fl. oz)
Accumulator Tank Max Pressure125 PSI (8.6 bar)
Accumulator Tank Pre-charge Pressure10 PSI (0.7 bar)
Nivell de soroll≤45dB
Diagram showing the dimensions of both the RO delivery pump and the accumulator tank.

Image 5.1: Detailed dimensions of the pump and accumulator tank.

6. Configuració i instal·lació

Follow these steps for proper installation of your RO Delivery Demand Pump system:

  1. Col·locació: Choose a location near your RO system and the point of use (e.g., faucet, refrigerator). Ensure the area is dry, protected from freezing, and has access to a 110V power outlet.
  2. Muntatge: Place the pump and accumulator tank on a stable, flat surface. Utilize the included anti-vibration rubber feet under the pump to minimize noise and vibration.
  3. Connexions: The system uses 1/4" OD quick-connect fittings. Ensure tubing is cut cleanly and inserted fully into the fittings for a leak-proof seal.
  4. Water Flow Path:
    • Connecteu el FORA port of your RO system to the IN port of the RO Delivery Pump.
    • Connecteu el FORA port of the RO Delivery Pump to the IN port of the Accumulator Tank.
    • Connecteu el FORA port of the Accumulator Tank to your water-using equipment (e.g., faucet, ice maker, refrigerator, coffee machine).
  5. Aïllament de canonades: Apply the provided pipe insulation tubing to reduce pipe vibration and noise.
  6. Connexió elèctrica: Once all water connections are secure, plug the pump into a grounded 110V electrical outlet.
  7. Comprovació de fuites: Slowly turn on the water supply to the RO system and inspect all connections for leaks. Tighten any leaking connections.
Image demonstrating the 1/4 inch quick connection design for easy installation.

Image 6.1: Illustration of the 1/4" quick connection for simple setup.

Detailed installation diagram showing the connection of the RO system, pump, accumulator tank, and various water outlets.

Image 6.2: Comprehensive installation diagram for connecting the pump system.

7. Instruccions de funcionament

Once installed and connected, the Moonshan RO Delivery Demand Pump operates automatically:

  1. Funcionament automàtic: The pump is equipped with a pressure switch. When water is drawn from the RO system (e.g., by opening a faucet or an appliance demanding water), the pressure in the line drops. The pump will automatically turn on when the pressure falls below approximately 70 PSI.
  2. Apagat automàtic: When the demand for water stops and the pressure in the system reaches approximately 60 PSI, the pump will automatically turn off.
  3. Accumulator Tank Function: The accumulator tank acts as a buffer, storing a small amount of pressurized water. This reduces the frequency of pump cycling, especially for small water draws, leading to quieter operation and extended pump life.
Diagram illustrating the automatic on/off operation of the pump based on water demand and pressure switch.

Image 7.1: Visual representation of the pump's automatic on/off functionality.

8. Manteniment

Regular maintenance ensures optimal performance and longevity of your pump system:

  • Inspeccionar connexions: Periodically check all water connections for leaks. Tighten fittings as necessary.
  • Exterior net: Keep the pump and tank exterior clean and free of dust or debris. Use a damp drap; no utilitzeu productes químics agressius.
  • Check for Unusual Noise/Vibration: If you notice increased noise or vibration, inspect the anti-vibration feet and pipe insulation. Ensure the pump is securely mounted.
  • Accumulator Tank Pressure: The accumulator tank is pre-charged. If you suspect issues with the tank, consult a professional. Do not attempt to alter the tank's pre-charge pressure without proper knowledge and tools.
  • Hivernització: If the pump is in an area subject to freezing, disconnect it and drain all water to prevent damage.

9. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves solucions:

ProblemaCausa possibleSolució
La bomba no s'encénNo power; Pressure switch not activated; Clogged inletCheck power connection; Ensure water demand is present; Inspect inlet for blockages.
Baixa pressió/cabal d'aiguaPartially closed valve; Clogged filter in RO system; Air in the line; Pump malfunctionCheck all valves are fully open; Replace RO filters if needed; Bleed air from the system; Contact support if pump is faulty.
La bomba fa cicles freqüentsSmall leak in the system; Accumulator tank issue; Pressure switch sensitivityCheck for leaks in all connections; Inspect accumulator tank for proper function; Contact support if cycling persists.
Excés de soroll/vibracióLoose mounting; Worn anti-vibration components; Air in pumpEnsure pump is securely mounted; Check and replace anti-vibration feet/tubing if worn; Bleed air from the system.
Fuites d'aigua de les connexionsLoose fittings; Damaged O-rings/tubingTighten quick-connect fittings; Inspect and replace O-rings or tubing if damaged.

10. Garantia i Suport

Moonshan products are manufactured to high-quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty details, please refer to the warranty card included with your product or contact Moonshan customer support.

If you encounter any issues or have questions regarding your RO Delivery Demand Pump, please contact our customer support team. Have your model number (MS-DP) and purchase information ready for faster service.

Informació de contacte: Please refer to the contact details provided on the product packaging or our official weblloc.

© 2026 Moonshan. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.