VEVOR KEX-16AC-T01

VEVOR Fuel Transfer Pump 110V 15GPM User Manual

Model: KEX-16AC-T01

1. Introducció

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR 110V 15GPM AC Electric Fuel Transfer Pump. Please read this manual thoroughly before use and retain it for future reference. This pump is designed for transferring gasoline, diesel, kerosene, biodiesel, and ethanol blends.

2. Instruccions de seguretat

ADVERTIMENT: Failure to follow these safety instructions can result in fire, explosion, electric shock, or serious injury.

  • Always operate the pump in a well-ventilated area.
  • Do not use this pump for transferring water, corrosive chemicals, or highly volatile liquids other than those specified.
  • Ensure all electrical connections are secure and comply with local electrical codes. The pump requires user-supplied wiring to connect to a power source.
  • Wear appropriate personal protective equipment (PPE), including eye protection and gloves, when handling fuels.
  • Keep ignition sources, open flames, and sparks away from the pump and fuel transfer area.
  • Do not operate the pump if any part is damaged or leaking.
  • Desconnecteu l'alimentació abans de realitzar qualsevol manteniment o servei.
  • The pump features built-in overheat protection. If the pump stops unexpectedly, allow it to cool down before restarting.

3. Què hi ha a la caixa

Verifiqueu que tots els components siguin presents i no estiguin danyats en desembalar-los:

  • 1 x Fuel Transfer Pump
  • 1 x Auto Shut-Off Fuel Nozzle
  • 1 x 13 ft (4 m) Rubber Outlet Hose
  • 1 x 1-3 ft (530-960 mm) PVC Inlet Hose (Telescoping Suction Pipe)
  • 1 x Junction Box
  • 1 x PTFE Tape
  • 1 x adaptador
  • 1 x Adapter Union
  • 2 x Wire Terminals
  • 1 x Manual d'usuari (aquest document)
VEVOR Fuel Transfer Pump with all included accessories and dimensions

Imatge: Més deview of the VEVOR Fuel Transfer Pump and its included accessories, along with key dimensions.

4. Especificacions

Número de model KEX-16AC-T01
Marca VEVOR
Caudal 15 GPM (57 L / min)
Voltage / Freqüència CA 110-120V, 60Hz
Max Suction Lift 8 peus (2.4 m)
Max Discharge Lift 37 peus (11.28 m)
Mida d'entrada 1 inch (25.4 mm) NPT
Mida de sortida 3/4 inch (19 mm) NPT
Hose Length (Outlet) 13 peus (4 m)
Material Ferro colat
Dimensions de l'article (L x A x A) 12.99 x 8.86 x 9.65 polzades (330 x 225 x 245 mm)
Pes net 32.63 lliures (14.8 kg)
Combustibles compatibles Gasoline, Diesel, Kerosene, Biodiesel, Ethanol Blends
Diagram showing max suction lift of 8 ft and max discharge lift of 37 ft, with inlet size 1 inch and outlet size 3/4 inch.

Image: Illustration of the pump's suction and discharge capabilities, including inlet and outlet sizes.

5. Instruccions de configuració

5.1 Muntatge de la bomba

  1. The pump is designed for fixed installation, typically on a 2-inch NPT drum opening.
  2. Ensure the mounting surface is stable and capable of supporting the pump's weight and operational forces.
  3. Securely thread the pump's inlet into the drum opening. Use PTFE tape on threads to ensure a leak-free seal.
VEVOR Fuel Transfer Pump mounted on a drum with a 2-inch NPT connection

Image: The fuel transfer pump securely mounted on a fuel drum, highlighting the standard 2-inch NPT connection.

5.2 Connexions de mànega

  1. Inlet Hose (Suction Pipe): Connect the telescoping PVC inlet hose to the pump's inlet. Adjust the length of the suction pipe to reach near the bottom of the fuel drum without touching it. Ensure a tight connection to prevent air leaks.
  2. Mànega de sortida: Connect the 13 ft (4 m) rubber outlet hose to the pump's outlet. Secure the auto shut-off fuel nozzle to the other end of the outlet hose. Use PTFE tape on all threaded connections to prevent leaks.

5.3 Connexió elèctrica

IMPORTANT: This pump does not come with a pre-wired plug. Electrical wiring must be performed by a qualified electrician in accordance with all local and national electrical codes. Incorrect wiring can lead to electric shock, fire, or damage to the pump.

  • Ensure the power source is 110-120V AC, 60Hz.
  • Connect the pump's electrical wires to a suitable power cord using the provided wire terminals and junction box.
  • Assegureu-vos una correcta connexió a terra per evitar riscos elèctrics.
  • The waterproof power switch should be easily accessible.
VEVOR Fuel Transfer Pump installed on a drum in an outdoor setting

Image: The fuel transfer pump ready for operation, demonstrating its robust cast iron construction suitable for outdoor use.

6. Instruccions de funcionament

6.1 Comprovacions prèvies a l'operació

  • Confirm all hose connections are tight and free of leaks.
  • Assegureu-vos que la bomba estigui ben muntada.
  • Verify the power connection is correct and safe.
  • Check that the fuel type in the drum is compatible with the pump.

6.2 Fuel Transfer Process

  1. Insert the auto shut-off fuel nozzle into the receiving tank's fill port.
  2. Turn on the pump using the power switch. The pump will begin transferring fuel.
  3. Monitor the fuel transfer. The auto shut-off nozzle is designed to stop the flow automatically when the receiving tank is full, preventing overfilling and spills.
  4. Once the transfer is complete or the nozzle has shut off, turn off the pump using the power switch.
  5. Carefully remove the nozzle from the receiving tank, allowing any residual fuel to drain.
Close-up of an auto shut-off fuel nozzle with automatic locking mechanism and pressure-sensing port

Imatge: Detallada view of the auto shut-off fuel nozzle, illustrating its safety features for preventing overfills.

Examples of the fuel transfer pump being used for refueling large ships, heavy trucks, agricultural machinery, and drawing fuel from drums

Image: Various applications of the VEVOR Fuel Transfer Pump, including refueling large vehicles and machinery.

7. Manteniment

7.1 Comprovacions periòdiques

  • Inspect hoses and connections for wear, cracks, or leaks before each use. Replace damaged components immediately.
  • Comproveu el cable d'alimentació per si hi ha danys.
  • Ensure the pump's housing is clean and free from debris.

7.2 Neteja i emmagatzematge

  • After use, wipe down the pump and nozzle with a clean cloth to remove any fuel residue.
  • Store the pump in a dry, secure location, away from direct sunlight and extreme temperatures.
  • Ensure all fuel is drained from hoses before long-term storage.
Close-up of the VEVOR Fuel Transfer Pump showing the internal motor with built-in overheat protection

Image: The pump's internal motor, featuring built-in overheat protection for extended service life and stable operation.

8. Solució De Problemes

Problema Causa possible Solució
La bomba no arrenca
  • Sense font d'alimentació
  • Cablejat incorrecte
  • S'ha activat la protecció contra el sobreescalfament
  • Interruptor danyat
  • Comproveu la connexió d'alimentació i l'interruptor.
  • Verify wiring by a qualified electrician.
  • Allow pump to cool down for 15-30 minutes.
  • Poseu-vos en contacte amb l'atenció al client per a la substitució de l'interruptor.
Low flow rate or no flow
  • Fuites d'aire a la línia d'aspiració
  • Clogged inlet filter or hose
  • Insufficient fuel in drum
  • Excessive lift height
  • Tighten all suction connections.
  • Inspeccioneu i elimineu qualsevol obstrucció.
  • Refill fuel drum.
  • Ensure operating within specified suction/discharge lift limits.
Fuga de combustible
  • Connexions de mànega soltes
  • Mànega o junta danyada
  • Tighten all connections, apply PTFE tape if necessary.
  • Substituïu els components danyats.

9. Informació de la garantia

VEVOR products are designed for durability and performance. For specific warranty terms and conditions applicable to your product, please refer to the warranty card included with your purchase or visit the official VEVOR weblloc web. Conserveu el rebut de compra com a comprovant de compra per a qualsevol reclamació de garantia.

10. Atenció al client

If you encounter any issues or have questions regarding the VEVOR Fuel Transfer Pump that are not covered in this manual, please contact VEVOR customer support. You can typically find contact information on the VEVOR weblloc web o a l'embalatge del producte.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.