SINOTIMER SVP719-1-63A

SINOTIMER SVP719 120VAC 63A Adjustable VoltagManual d'usuari del relé de protecció contra sobretensions

1. Producte acabatview

The SINOTIMER SVP719 is a 3-in-1 adjustable voltage surge protector relay designed for single-phase 120VAC systems. It integrates over-voltage protecció, sota-voltage protection, current limiting, and energy metering functions. This device features three digital LED displays for real-time monitoring of voltage, current, and energy consumption (kWh). It is equipped with automatic recovery capabilities, ensuring electrical equipment protection by cutting off power during abnormal conditions and automatically restoring it when parameters return to normal. The unit is designed for easy installation on a universal DIN 35mm standard guide rail.

Davant view of the SINOTIMER SVP719 Adjustable Voltage Surge Protector with LED displays.

Davant view of the SINOTIMER SVP719 Adjustable Voltage Surge Protector.

Detailed product information diagram of the SINOTIMER SVP719 showing input/output, LED displays for voltage, current, kilowatt-hour, and control buttons.

Detailed diagram of the SVP719 showing displays and controls.

2. Informació de seguretat

Llegiu atentament totes les instruccions de seguretat abans de la instal·lació i el funcionament. Si no seguiu aquestes instruccions, podeu patir descàrregues elèctriques, incendis o lesions greus.

  • La instal·lació només l'ha de fer personal qualificat.
  • Ensure the main power supply is disconnected before any wiring or maintenance.
  • Comproveu el vol correctetage and current ratings for your application.
  • No utilitzeu el dispositiu en mullat o damp condicions.
  • Do not attempt to repair or modify the device. Contact qualified service personnel.

3. Configuració i instal·lació

The SVP719 is designed for easy installation on a standard 35mm DIN rail. Follow the wiring diagram below for proper connection.

3.1 Muntatge

Mount the device securely onto a 35mm DIN rail within an electrical enclosure.

3.2 Connexions de cablejat

Connect the device according to the provided wiring diagram. Ensure all connections are tight and secure to prevent loose contacts and potential hazards.

  • N Input: Connect the neutral wire from the power source.
  • L Input: Connect the live wire from the power source.
  • N Output: Connect the neutral wire to the load.
  • L Output: Connect the live wire to the load.
Wiring diagram for the SINOTIMER SVP719 Adjustable Voltage Surge Protector, illustrating connections to power switch and air circuit breaker.

Wiring Diagram for SVP719.

4. Instruccions de funcionament

The SVP719 features three LED displays and four control buttons for monitoring and configuration.

4.1 Pantalles LED

  • Voltage Display (V): Mostra el vol en temps realtage del circuit.
  • Current Display (A): Shows the real-time current flowing through the circuit.
  • Kilowatt-hour Display (kWh): Shows the accumulated energy consumption.

4.2 botons de control

  • Botó SET: Used to enter the parameter setting mode and cycle through different adjustable parameters.
  • Botó de fletxa amunt: Used to increase the value of a selected parameter.
  • Botó de fletxa avall: Used to decrease the value of a selected parameter.
  • Botó ON/OFF: Used to manually turn the power supply to the load ON or OFF.

4.3 Manual ON/OFF Operation

Premeu el botó ON/OFF button to manually switch the power to the connected load. The display will show 'OFF' when power is disconnected and 'ON' when connected.

4.4 Kilowatt-hour (kWh) Reset

To reset the accumulated Kilowatt-hour (kWh) reading, press the Fletxa cap avall i SET buttons simultaneously. The kWh display will reset to 000.0.

This video demonstrates the key features and operation of the SINOTIMER SVP719, including parameter adjustment, over-voltage protecció, sota-voltage protection, and manual ON/OFF control.

5. Configuració dels paràmetres

The SVP719 allows for adjustment of various protection parameters. All parameters are adjustable within specified ranges.

5.1 Entering Setting Mode

Manteniu premut el botó SET button for approximately 3 seconds to enter the parameter setting mode. The first adjustable parameter will appear on the display.

5.2 Cycling Through Parameters

Once in setting mode, short press the SET button to cycle through the parameters sequentially. Each press will display the next parameter.

5.3 Adjusting Parameter Values

When a desired parameter is displayed, use the Fletxa amunt i Fletxa cap avall buttons to adjust its value. The display will flash while adjusting.

5.4 Saving Settings and Exiting

After adjusting a parameter, wait for approximately 5 seconds without pressing any button. The device will automatically save the new setting and exit the setting mode, returning to normal operation.

5.5 Paràmetres ajustables

  • U> (Over-voltage Protection Value): Sets the upper voltage limit. If the voltage exceeds this value, the protector will trip.
  • U< (Under-voltage Protection Value): Sets the lower voltage limit. If the voltage drops below this value, the protector will trip.
  • I> (Over-current Protection Value): Sets the maximum current limit. If the current exceeds this value, the protector will trip.
  • t-on (Fault Recovery Delay Time): Sets the delay before the device automatically reconnects after a fault (over/under voltage, over-current) has cleared.
  • t-off (Reset/Start Delay): Sets the delay for initial power-on or manual reset.
  • CAL-A (Current Calibration): Allows for fine-tuning of the current measurement.
  • CAL-V (Voltage Calibration): Allows for fine-tuning of the voltage mesura.
  • CLP (Clear kWh): Resets the energy consumption counter.

6. Característiques de protecció

The SVP719 provides robust protection for your electrical equipment.

6.1 Sobrevoltage Protecció

When the circuit voltage supera el conjunt de sobrevoltage protection value (U>), the protector will instantaneously cut off the power supply to prevent damage to connected devices. The display will indicate an over-voltage condició.

6.2 Subvoltage Protecció

If the circuit voltage drops below the set under-voltage protection value (U<), the protector will immediately disconnect the power. The display will indicate an under-voltage condició.

6.3 Protecció contra sobreintensitat

Should the current drawn by the load exceed the set over-current protection value (I>), the device will trip and cut off power to protect the circuit and load.

6.4 Automatic Recovery

After a fault condition (over-voltage, baix voltage, or over-current) has been detected and the power supply is cut off, the SVP719 will continuously monitor the circuit. Once the voltage and current return to normal operating ranges for the duration of the set recovery delay time (t-on), the protector will automatically restore power to the load.

7. Manteniment

To ensure optimal performance and longevity of your SVP719, follow these simple maintenance guidelines:

  • Regularly inspect the device for any signs of physical damage or loose connections.
  • Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning.
  • No utilitzeu netejadors abrasius ni dissolvents.
  • Assegureu-vos que hi hagi una ventilació adequada al voltant del dispositiu per evitar el sobreescalfament.

8. Solució De Problemes

If you encounter issues with your SVP719, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
El dispositiu no s'encénNo input power; incorrect wiringCheck main power supply; verify wiring connections as per diagram.
Power cuts off frequentlyVoltage/current outside set limits; sensitive settingsComprova el volum realtage/current; adjust protection parameters (U>, U<, I>) to appropriate levels for your load.
Device does not recover automaticallyFault condition still present; recovery delay too longAssegureu-vos voltage/current has returned to normal; check and adjust 't-on' recovery delay setting.
kWh reading is inaccurateCal calibratgePerform current and voltage calibration (CAL-A, CAL-V) if you have a reference meter.

9. Especificacions

Technical specifications for the SINOTIMER SVP719-1-63A model:

lateral view of the SINOTIMER SVP719 showing technical specifications printed on the casing.

Technical specifications printed on the device casing.

CaracterísticaEspecificació
MarcaSINOTIMER
Número de modelSVP719-1-63A
Voltage120 volts de corrent altern
Corrent màxima63 Amps
Nombre de punts de venda1
Característica especialSurge Protection, Over-voltagProtecció electrònica, sota volumtage Protection, Current Limiting, Energy Metering
Tipus d'endoll d'alimentacióTipus A - 2 pins (nord-americà)
Instal·lacióDIN 35mm Standard Guide Rail
UPC607606586190

10. Garantia i Suport

The SINOTIMER SVP719-1-63A comes with a 1 anys de garantia del fabricant.

For technical support, warranty claims, or further assistance, please contact SINOTIMER customer service through their official channels or the retailer from whom the product was purchased. Please have your product model number (SVP719-1-63A) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.