AOPUTTRIVER AP-9000F

AOPUTTRIVER AP-9000F Hot Wire Anemometer User Manual

Model: AP-9000F

1. Introducció i finalview

The AOPUTTRIVER AP-9000F is a professional handheld hot wire anemometer designed for precise measurement of air velocity, airflow volume (CFM/CMM), and air temperature. This device is equipped with a retractable sensor probe, making it suitable for various applications, including HVAC system diagnostics, environmental monitoring, and industrial air flow analysis. This manual provides essential information for the safe and effective operation of your AP-9000F anemometer.

2. Què hi ha a la caixa

En desempaquetar, comproveu que tots els elements que s'enumeren a continuació hi són presents i en bon estat:

  • AP-9000F Hot Wire Anemometer Unit
  • Manual d'usuari
  • Cable de dades tipus C
Contents of the AP-9000F package including the anemometer, manual, and charging cable.
Figure 2.1: Contents of the AP-9000F package. Includes the main unit, user manual, and Type-C data cable.

3. Característiques del producte

The AP-9000F anemometer offers a range of features designed for precision and convenience:

  • Mesura 3 en 1: Accurately measures wind speed (m/s, km/h, ft/min, knots, mph), airflow (CFM/CMM), and wind temperature (°C/°F).
  • Retractable Sensor Probe: Features a flexible, extendable probe tip for convenient measurements in confined or hard-to-reach spaces, such as air conditioning vents. Probe dimensions: 298.5 × 40.84 × 23.7 mm.
  • Pantalla LCD: A clear, backlit LCD presents wind speed (Max, Min, Real-time), airflow, temperature, and humidity data. Includes anti-interference buttons and a low battery indicator.
  • Interfície tipus C: Equipped with a Type-C charging port and powered by a 1000mAh lithium-ion battery. Supports an optional auto-shutdown function.
  • Aplicació àmplia: Suitable for environmental measurements, air transportation, and air conditioning monitoring systems.
Diagram highlighting key features of the handheld anemometer including 5 units, MAX/MIN/AVG, LCD Backlit, C/F optional, automatic power off, airflow/temperature, and 360 degree bending probe.
Figure 3.1: Key features of the AP-9000F handheld anemometer.
Image showing the retractable probe being used for small space measurement in an air conditioning unit, demonstrating its 360 degree revolve capability.
Figure 3.2: The retractable sensor probe allows for 360° rotation, facilitating measurements in tight or small spaces.

4. Configuració

4.1 Càrrega de la bateria

The AP-9000F is powered by a built-in 1000mAh lithium-ion battery. Before first use, or when the low battery indicator appears on the LCD, charge the device using the provided Type-C data cable.

  • Connect the Type-C cable to the charging port on the anemometer and the other end to a standard USB power adapter (not included).
  • Una càrrega completa sol trigar entre 2 i 3 hores.
  • Nota: The device cannot be turned on or operated while it is charging.

4.2 Extending the Sensor Probe

The hot wire sensor is located at the tip of the retractable probe. Carefully extend the probe to the desired length for measurement. The probe can be rotated 360 degrees for optimal positioning.

  • Gently pull the probe from the main unit to extend it.
  • Adjust the angle of the probe tip as needed.
  • After use, retract the probe back into the unit for protection.

5. Instruccions de funcionament

5.1 Disseny i botons del dispositiu

Labeled diagram of the AOPUTTRIVER AP-9000F Hot Wire Anemometer, showing the sensor, sensor protective cover, connecting cable, LCD screen, power button, wind speed/volume unit switch button, Max/Min/real-time value switch button, C/F switch button, data hold button, and set air volume area button.
Figura 5.1: Mésview of the AP-9000F anemometer and its controls.
  • Power Button (Red Circle): Premeu per encendre o apagar el dispositiu.
  • Botó MODE: Switches between different measurement modes (e.g., wind speed, airflow).
  • Botó UNIT: Changes the unit of measurement for wind speed (m/s, km/h, ft/min, knots, mph) or airflow (CFM, CMM).
  • Botó SET: Used to set the air volume area for accurate CFM/CMM calculations.
  • Botó MAX/MIN: Toggles between maximum, minimum, and real-time values on the display.
  • Botó HOLD: Freezes the current reading on the display. Press again to release.
  • Botó °C/°F: Switches the temperature unit between Celsius and Fahrenheit.

5.2 Procediment de mesura bàsic

  1. Encès: Premeu el botó Botó d'engegada to turn on the anemometer. The LCD will illuminate.
  2. Extend Probe: Carefully extend the sensor probe and position it in the airflow you wish to measure. Ensure the sensor tip is fully exposed to the air stream.
  3. Seleccioneu el mode: Premeu el botó Botó MODE to select between wind speed, airflow, or temperature measurement.
  4. Seleccioneu la unitat: Premeu el botó Botó UNIT to choose your preferred unit (e.g., m/s, CFM, °C).
  5. Set Area (for Airflow): If measuring airflow (CFM/CMM), press the Botó SET to input the cross-sectional area of the duct or vent. Refer to the specifications for area input range.
  6. Llegir mesura: The current readings will be displayed on the LCD.
  7. Conservació de dades: Premeu el botó Botó HOLD to freeze the current reading. Press again to resume live measurement.
  8. Màx./Mín./Mitjana: Utilitza el Botó MAX/MIN a view the maximum, minimum, or average readings recorded during the measurement session.
The AP-9000F LCD display showing wind speed, airflow, temperature, and humidity data with backlight activated.
Figure 5.2: The clear LCD display with backlight for easy reading in various lighting conditions.
Screenshots of the AP-9000F display showing Original screen, MAX, MIN, and AVG measurement modes for airflow.
Figure 5.3: The three measurement modes (Original, MAX, MIN, AVG) available on the AP-9000F.
Close-up of the AP-9000F display showing the HOLD button being pressed to retain a reading, useful in dark environments.
Figure 5.4: Using the HOLD button to freeze the display for convenient reading.

6. Manteniment

6.1 Neteja del dispositiu

  • Netegeu la unitat principal amb un drap suau i sec. No utilitzeu productes de neteja abrasius ni dissolvents.
  • For the sensor probe, gently clean any dust or debris. Avoid touching the delicate hot wire sensor directly.

6.2 Cura i emmagatzematge de la bateria

  • Recarrega la bateria regularment, fins i tot si el dispositiu no s'utilitza amb freqüència, per mantenir-ne l'estat.
  • Store the anemometer in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ensure the sensor probe is fully retracted and protected during storage.

7. Solució De Problemes

If you encounter issues with your AP-9000F, please refer to the following common problems and solutions:

ProblemaCausa possibleSolució
El dispositiu no s'encénLow battery; Device is chargingCharge the battery fully; Disconnect from charger before powering on.
Lectures inexactesSensor obstructed or dirty; Incorrect unit/mode selected; Probe not properly positionedClean the sensor gently; Verify selected mode and unit; Ensure sensor is fully in the airflow.
La pantalla està en blanc o congeladaBattery low; HOLD function active; Device malfunctionRecharge battery; Press HOLD button to release; If problem persists, contact support.
Cannot change units/modesButtons unresponsive; Device in a locked stateEnsure buttons are pressed firmly; Power cycle the device (turn off and on).

8. Especificacions

Detailed technical specifications for the AOPUTTRIVER AP-9000F Hot Wire Anemometer:

ParàmetreValor
Interval de mesura de la velocitat del vent0.1 – 30 m/s
Air Temperature Measurement Range0 – 45 °C (32 – 113 °F)
Airflow Measurement Range (CFM)0 – 999,900 ft³/min
Airflow Measurement Range (CMM)0 – 999,900 m³/min
Dimensions de la sonda298.5 × 40.84 × 23.7 mm
Tipus de bateria1000mAh Ió de liti
Port de càrregaTipus-C
MostraLCD amb llum de fons
Pes0.12 lliures (aprox. 54 g)
Table detailing Airflow Measurement units, range, resolution, and area for CMM and CFM.
Figure 8.1: Detailed specifications for Airflow Measurement (CMM/CFM).

9. Garantia i Suport

9.1 Informació de la garantia

AOPUTTRIVER products are manufactured to high-quality standards. This product is covered by a limited warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions, or visit the official AOPUTTRIVER weblloc per a més detalls.

9.2 Atenció al client

For technical assistance, troubleshooting, or inquiries regarding your AP-9000F Hot Wire Anemometer, please contact AOPUTTRIVER customer support. Contact information can typically be found on the product packaging, the official AOPUTTRIVER weblloc web o a través de la vostra plataforma de compra.

When contacting support, please have your product model (AP-9000F) and a detailed description of the issue ready.

© 2023 AOPUTTRIVER. All rights reserved.