VEVOR BT-BPT190CL

VEVOR 80 CFM Bathroom Exhaust Fan with LED Light

Model: BT-BPT190CL

1. Instruccions de seguretat

Read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or personal injury.

  • Desconnecteu sempre l'alimentació al quadre de servei abans de cablejar o fer el manteniment de la unitat.
  • Ensure all wiring complies with local electrical codes and standards.
  • Aquesta unitat ha d'estar correctament connectada a terra.
  • Do not install this fan in a cooking area.
  • Never place objects into the fan grille.
  • Utilitzeu ulleres i guants de seguretat durant la instal·lació.
  • Mantenir els nens allunyats de la zona de treball.

2. Producte acabatview

The VEVOR 80 CFM Bathroom Exhaust Fan with LED Light is designed to provide efficient ventilation and adjustable lighting for various indoor spaces. It features a low-noise AC motor and three color temperature options for the integrated LED light.

Característiques principals:

  • Ventilació potent: Delivers 80 CFM airflow, suitable for areas up to 161 sq. ft. (15 m²).
  • Funcionament silenciós: Operates at a low noise level of 1.5 sones (≤60dB).
  • Llum LED ajustable: Offers 3000K (warm), 4000K (neutral), and 5000K (cool) color temperatures.
  • Construcció duradora: ETLus certified with a damp-resistant housing and cold-rolled steel material.
VEVOR Bathroom Exhaust Fan in a modern bathroom, showing efficient airflow

Image: The VEVOR exhaust fan installed in a bathroom ceiling, demonstrating its airflow for effective damp i eliminació d'olors.

Interna view of the VEVOR exhaust fan showing the AC motor and ETLus certification

Imatge: Un retall view of the fan's internal components, highlighting the efficient AC motor and the ETLus certification for quality assurance.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • 1 x VEVOR Bathroom Exhaust Fan with LED Light
  • 4 x Large Flat Self-Tapping Screws
  • 1 x Two-Way Switch
  • 1 x Manual d'usuari (aquest document)

4. Especificacions

Diagram showing VEVOR exhaust fan dimensions and a table of specifications

Image: Detailed dimensions of the exhaust fan unit and a summary of its technical specifications.

EspecificacióValor
Número de modelBT-BPT190CL
Poder45W
MaterialAcer laminat en fred
Capacitat de flux d'aire80 CFM
Diàmetre del tub4 polzades / 101.6 mm
Temperatura de color3000K / 4000K ​​/ 5000K
Nivell de soroll≤1.5 sones
Pes net5.73 lliures / 2.6 kg
Dimensions de l'article (D x W x H)300 x 260 x 170 mm
Tipus de motorMotor AC
Voltage / Freqüència120V 60Hz ~
Velocitat del motor950 r/min
Potència del motor32W

5. Instal·lació

Follow these steps for proper installation of your exhaust fan. Professional installation is recommended if you are not familiar with electrical wiring.

Passos d'instal·lació:

  1. Prepareu l'obertura del sostre: Confirm the ceiling cutout dimensions are approximately 7.68 x 7.60 inches (195.1 x 193.0 mm).
  2. Detach Wiring Box Lid: Locate and detach the lid of the wiring box on the fan unit.
  3. Connecteu el cablejat: Connect the household electrical wires to the fan's quick connectors. Ensure correct connections: Black (Live), White (Neutral), Green (Ground).
  4. Install Ducting: Connect a standard 4-inch duct (not included) to the fan's exhaust port and seal it securely.
  5. Insert into Ceiling: Carefully insert the fan unit into the prepared ceiling opening.
  6. Assegura el ventilador: Pinch the installation springs on the fan housing and push the unit up until it fits snugly against the ceiling.
  7. Comprovació final: Ensure the fan is securely mounted and all connections are tight.
Hands holding the VEVOR exhaust fan unit, showing dimensions and a drill for installation

Image: A visual guide to the fan's dimensions and the use of a drill for securing the unit during installation.

Step-by-step diagram for installing the VEVOR bathroom exhaust fan

Image: A diagram illustrating the seven key steps for installing the exhaust fan, from preparing the opening to securing the unit.

Video d'instal·lació:

Video: An official VEVOR video demonstrating the installation process for the bathroom exhaust fan with light.

6. Funcionament

The VEVOR exhaust fan features separate controls for the fan and the LED light, allowing independent operation and light color adjustment.

Funcionament del ventilador:

Use the designated fan switch on your wall control to turn the exhaust fan ON or OFF. The fan will operate at its standard 80 CFM setting.

LED Light Operation and Color Temperature Adjustment:

The LED light offers three color temperature options: 3000K (Warm), 4000K (Neutral), and 5000K (Cool). To cycle through these options:

  1. Turn the light switch ON. The light will illuminate at its last-used color temperature.
  2. To change the color temperature, quickly toggle the light switch OFF and then ON again. The light will switch to the next color temperature in the sequence.
  3. Repeat toggling the switch until your desired color temperature is achieved.
Images showing the VEVOR exhaust fan light at 5000K, 4000K, and 3000K color temperatures

Image: Visual representation of the three adjustable light color temperatures (5000K, 4000K, 3000K) available with the fan's LED light.

7. Manteniment

Un manteniment regular garanteix un rendiment òptim i una llarga vida útil del ventilador.

Neteja de la reixa:

  1. Desconnecteu l'alimentació: Desconnecteu sempre l'alimentació a l'interruptor automàtic abans de netejar.
  2. Elimina la graella: Gently pull down the grille to detach it from the fan housing.
  3. Neteja: Wash the grille with a mild detergent and warm water. Rinse thoroughly and dry completely before reattaching.
  4. Torneu a col·locar la reixa: Align the grille springs with the slots in the fan housing and push up until it snaps into place.

Cleaning the Fan Motor and Blades:

Periodically, inspect the fan motor and blades for dust buildup. If necessary, carefully wipe them with a damp cloth. Do not immerse electrical components in water.

8. Solució De Problemes

If you encounter issues with your VEVOR exhaust fan, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
El ventilador no s'encénSense font d'alimentació
Connexió de cablejat solta
Interruptor defectuós
Comproveu l'interruptor de circuit i l'interruptor de paret
Verify all wiring connections are secure (ensure power is off)
Proveu o substituïu l'interruptor
La llum no s'encénNo power supply to light
Connexió de cablejat solta
Mòdul LED defectuós
Check light switch and circuit breaker
Verify wiring connections (ensure power is off)
Contact customer support for LED module replacement
El ventilador fa sorollAcumulació de pols a les fulles
Muntatge solt
Obstruction in ducting
Clean fan blades and motor
Ensure fan is securely mounted to the ceiling
Check ductwork for blockages
Poca ventilacióBlocked ducting
Fan size inadequate for room
Fuga d'aire excessiva
Clear any obstructions in the ductwork
Ensure fan is correctly sized for the room area
Seal any gaps around the fan housing or duct connections

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb el servei d'atenció al client de VEVOR.

9. Garantia i Suport

VEVOR products are designed for durability and performance. For warranty information or technical support, please refer to the warranty card included with your product or visit the official VEVOR weblloc web. Conserveu el rebut de compra com a comprovant de compra.

© 2023 VEVOR. Tots els drets reservats.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.