PowMr POW-Sunsmart SP5.2

PowMr 5200W Hybrid Solar Inverter (Model POW-Sunsmart SP5.2) Instruction Manual

Guia completa per a la instal·lació, el funcionament i el manteniment.

1. Introducció

This manual provides essential information for the safe and efficient operation of your PowMr 5200W Hybrid Solar Inverter, model POW-Sunsmart SP5.2. This device integrates a 5200W pure sine wave inverter, a 100A MPPT solar charge controller, and a 6000W PV input capability. It is designed for various applications including home, office, RV, boat, and off-grid systems, supporting both battery-connected and batteryless operations.

2. Informació de seguretat

Llegiu atentament totes les instruccions i advertències abans de la instal·lació i el funcionament. Si no seguiu aquestes instruccions, podeu patir descàrregues elèctriques, incendis o lesions greus. Conserveu aquest manual per a futures consultes.

  • La instal·lació ha de ser realitzada per personal qualificat.
  • Ensure all power sources (solar, utility, battery) are disconnected before installation or maintenance.
  • No desmunteu l'inversor. No hi ha peces a l'interior que l'usuari pugui reparar.
  • Assegureu-vos de posar a terra correctament l'inversor.
  • Avoid exposing the inverter to rain, snow, or liquids.
  • Operate the inverter within its specified voltage i intervals de corrent.

3. Configuració i instal·lació

3.1 Producte acabatview

The PowMr 5200W Hybrid Solar Inverter combines multiple functions into one unit, including a pure sine wave inverter, MPPT solar charge controller, and battery charger. It features a clear LCD display for monitoring and configuration.

Inversor solar híbrid PowMr 5200W frontal view

Imatge: Frontal view of the PowMr 5200W Hybrid Solar Inverter, showing the LCD display and branding.

3.2 Diagrama de connexió

Refer to the following diagram for proper connection of solar panels, battery, AC input (utility/generator), and AC output (home loads).

Connection Diagram for PowMr 5200W Hybrid Solar Inverter

Image: Detailed connection diagram illustrating how to connect solar panels, mains power/generator, battery, and home loads to the inverter.

3.3 Connexions de terminals

Identify the various ports and terminals on the inverter for correct wiring.

Inverter terminal connections diagram

Image: Diagram showing the AC input, AC output, PV input, dry contact, battery port, ON/OFF switch, current sharing port, RS485, USB, and cooling fans.

Important: Ensure all connections are secure and correctly polarized. Use appropriate wire gauges for all connections.

3.4 Funcionament en paral·lel

The inverter supports parallel operation for increased power output and multi-phase configurations. Up to 6 units can be connected in parallel.

  • Fase única: Up to 2 inverters for 10000W output.
  • Tres fases: Up to 3 inverters for 15000W output.
  • Split Phase: Up to 6 inverters for 30000W output.
Parallel connection configurations for PowMr 5200W Hybrid Solar Inverter

Image: Diagrams illustrating single-phase, three-phase, and split-phase parallel connection setups for multiple inverters.

Video: This video demonstrates how to configure two SP5K inverters for a parallel split-phase 240V output, providing a visual guide for advanced setups.

Video: This video explains the support for single-phase, split-phase, and three-phase parallel configurations, detailing how to expand the system's capacity.

4. Instruccions de funcionament

4.1 Pantalla LCD i controls

The inverter features an LCD HD display for monitoring system status and configuring settings. Use the control buttons to navigate menus and adjust parameters.

LCD HD Display Screen and control buttons

Image: Close-up of the LCD display showing various indicators like battery capacity, load percentage, utility, generator, solar power, and home appliances. It also highlights the control buttons: Enter/Exit Settings, Option Increase, Option Decrease, and OK/Enter Options.

4.2 modes de càrrega

The inverter offers four distinct charging modes to optimize battery charging based on available power sources.

  • Solar Primer: Prioritizes solar power for charging. Grid charging starts only if PV fails.
  • Plats principals primer: Prioritizes mains power for charging. PV charging starts only if mains fails.
  • Càrrega híbrida: Prioritizes PV MPPT charging, supplementing with mains power if PV energy is insufficient.
  • Només solar: Només s'inicia la càrrega fotovoltaica; no hi ha càrrega de la xarxa elèctrica.
Four Charging Modes diagram

Image: Visual representation of the four charging modes: Solar First, Utility First, Solar and Utility (Hybrid), and Only Solar, showing power flow from solar, utility, and battery.

4.3 Modes de sortida

Select from four output modes to manage power delivery to your loads.

  • Solar Primer: Maximitza l'ús de l'energia solar verda. Apte per a regions amb xarxes elèctriques estables.
  • Plats principals primer: Switches to inverter power supply only when Mains power has failed (UPS function).
  • Inversor primer: Switches to Mains power supply only when the battery is under-voltage. Maximizes DC energy use.
  • Sortida híbrida i connexió a la xarxa: In utility bypass state, if no battery is connected or battery is full, load is supplied by PV and utility. Surplus PV can be fed back to the grid if grid connection is enabled.
Four Output Modes diagram

Image: Visual representation of the four output modes: Solar First, Mains First, Inverter First, and Hybrid Output with Grid Connection, showing power flow to home loads.

4.4 Battery Compatibility and Batteryless Mode

The inverter is compatible with various 48V battery types and supports operation without a battery.

  • Tipus de bateries compatibles: AGM, Gel, Lead-acid, Lithium, LiFePO4, and User-Defined.
  • Batteryless Mode: Can power loads directly from PV or AC grid without a connected battery.
  • Activació de la bateria de liti: Features a dual activation function to wake up dormant Li-ion batteries using mains or PV power.
Battery compatibility and batteryless mode

Image: Diagram showing various battery types (FLD, SLD, AGM, GEL, LI, USER) compatible with the inverter and highlighting the batteryless mode feature.

Compatible with 48V battery types and batteryless mode

Image: Another visual showing compatibility with GEL, AGM, Flooded, LiFePO4, Lithium, and User-Defined 48V battery types, emphasizing the batteryless mode.

4.5 ECO Mode and Time-of-Use Programming

The inverter includes an ECO mode for energy saving and supports time-of-use programming.

  • Mode ECO: If the load is less than 50W, the inverter delays for 5 minutes then shuts off. It restarts output when the load increases.
  • Time-of-Use Programming: Allows for 24/7 programming of off-peak charging and discharging to optimize energy costs.
Peak-Valley Electricity Tariff and Time-of-Use

Image: Graph illustrating peak-valley electricity tariffs and how sectioned charging and discharging functions can be programmed to store excess solar power for nighttime use, reducing electricity expenses.

5. Manteniment

Un manteniment regular garanteix la longevitat i el rendiment òptim del vostre inversor.

  • Keep the inverter clean and free from dust. The unit features a dust-proof cover.
  • Ensure proper ventilation around the inverter. The cooling fans should not be obstructed.
  • Comproveu periòdicament totes les connexions elèctriques per comprovar si estan ben ajustades i si hi ha signes de corrosió.
  • Monitor the LCD display for any error codes or warnings.
Inverter features including dust-proof cover and cooling fan

Image: Highlights key features of the inverter including the LCD HD Display, MPPT Controller, Pure Sine Wave output, Dust-Proof Cover, and Cooling Fan system.

6. Solució De Problemes

This section provides guidance for common issues. For complex problems, contact customer support.

6.1 Error Codes and Fault Reference

Scan the QR code below for a detailed fault code reference guide.

QR codes for User Guide and Fault Code Reference

Image: Displays two QR codes. The left QR code links to the User Guide, and the right QR code links to the Fault Code Reference for the POW-SunSmart SP5K inverter.

Guia de l'usuari: https://qrco.de/bfKt8J

Fault Code Reference: https://qrco.de/bfKt3n

6.2 Característiques de protecció

The inverter is equipped with comprehensive 360° protection features:

  • Mains input over/under voltage protecció
  • Battery over/low voltage protecció
  • Protecció contra curtcircuits de sortida de càrrega
  • Protecció de sobrecàrrega
  • Protecció de sobretemperatura
  • Protecció de polaritat inversa PV
  • Protecció de corrent inversa nocturna fotovoltaica
  • CAN communication loss protection
360 degree protection features of the inverter

Image: Diagram highlighting the 360° protection features of the inverter, including various voltage, current, temperature, and communication safeguards.

7. Especificacions

CaracterísticaEspecificació
Potència de sortida nominal5200W
Màx. Circuit obert PV Voltage500Vdc
MPPT Voltage Rang120Vdc
Màx. Potència d'entrada fotovoltaica6000W
Corrent d'entrada fotovoltaica màxim22A
Max Charger Current (settable)100A
Vol. d'entrada nominal de CAtage110/120Vac
Volum d’entrada de CAtage Rang90Vac~140Vac ±2%
Freqüència50 Hz/60 Hz
Fase120V (single phase), 120V/240V (split phase), 208V (2/3 phase)
Suport paral·lelFins a 6 unitats
Interfícies de comunicacióCAN, USB, RS485, WiFi, GPRS
Dimensions (L x A x A)13 cm de llargada x 5 cm d'amplada x 17 cm d'alçada
Pes30.8 lliures (14 kg)
Electrical Output WaveformOnda senyal pura
Tipus de visualitzacióLCD
Transition Time (Grid to Inverter)<20 ms

8. Garantia i Suport

8.1 Informació de la garantia

PowMr offers a 12-month warranty service per a aquest producte. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.

8.2 Atenció al client

For any questions, technical assistance, or warranty inquiries, please contact PowMr customer support. You can also refer to the user guide and fault code reference via the QR codes provided in the Troubleshooting section.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.