Wiltec 65829 (18600 L/h)

Wiltec Pool Pump 18600 L/h User Manual

Model: 65829 (18600 L/h) | Brand: Wiltec

1. Introducció

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wiltec Pool Pump, model 65829. This pump is designed for circulating and filtering water in pools ranging from 74 to 110 cubic meters, offering a high flow rate of 18,600 liters per hour and a maximum head of 13 meters. It is compatible with sand filter systems and features an integrated pre-filter for enhanced protection.

Wiltec Pool Pump 18600 L/h installed next to a swimming pool

Figura 1: Wiltec Pool Pump 18600 L/h in a typical pool setup. This image shows the pump connected to a pool system, highlighting its compact design and connection points.

2. Informació de seguretat

Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

  • Desconnecteu sempre la bomba de la xarxa elèctrica abans de realitzar qualsevol manteniment o neteja.
  • Ensure the electrical installation complies with local regulations and is protected by a Residual Current Device (RCD) with a tripping current not exceeding 30 mA.
  • No feu funcionar la bomba si el cable d'alimentació o l'endoll estan danyats.
  • The pump must be installed on a stable, level surface, protected from direct sunlight and adverse weather conditions.
  • Ensure adequate ventilation around the pump motor to prevent overheating.
  • This pump is designed for fresh water only, with a liquid temperature range of 0-35°C. Do not use with corrosive, flammable, or explosive liquids.

For detailed safety guidelines, please refer to the official Safety Information PDF document: Informació de seguretat (PDF)

3. Components i dimensions del producte

The Wiltec Pool Pump consists of a robust motor, a pump housing with an integrated pre-filter, and inlet/outlet connections. Understanding the dimensions is crucial for proper installation and space planning.

Technical drawing showing the dimensions of the Wiltec Pool Pump

Figura 2: Product Dimensions. This diagram illustrates the pump's overall length (580 mm), width (242 mm), and height (367 mm), along with specific measurements for connections and components.

Els components clau inclouen:

  • Pre-filter Basket: Located at the inlet, designed to capture debris larger than 3.9 mm.
  • Motor: 750W copper-wound motor with thermal overload protection.
  • Carcassa de la bomba: Construcció de plàstic durador.
  • Entrada / sortida: Standard connections for pool hoses.

4. Configuració i instal·lació

Proper installation is vital for the pump's performance and longevity. It is recommended that installation be performed by a qualified technician.

  1. Col·locació: Position the pump on a firm, level surface as close to the pool as possible to minimize suction lift. Ensure it is below the water level if possible for self-priming.
  2. Muntatge: Secure the pump to the surface using appropriate fasteners to prevent vibration and movement.
  3. Connexions de fontaneria: Connect the pump's inlet to the pool skimmer/main drain line and the outlet to the sand filter and return lines. Ensure all connections are watertight using thread sealant tape or appropriate gaskets.
  4. Connexió elèctrica: Connect the pump to a dedicated, properly grounded electrical circuit protected by an RCD. Verify that the power supply voltage coincideix amb els requisits de la bomba (230 V, 50 Hz).
  5. Cebament: Before first use, fill the pre-filter housing with water to ensure the pump is primed. This prevents dry running and potential damage.

5. Instruccions de funcionament

Once installed and primed, the pump is ready for operation.

  1. Inici de la bomba: Ensure all valves are open and the pre-filter is full of water. Connect the pump to the power supply. The pump will start circulating water.
  2. Supervisió del rendiment: Observe the water flow and pressure gauge (if installed on your filter system) to ensure optimal operation. The pump is designed for a maximum flow rate of 18,600 L/h and a maximum head of 13 meters.
  3. Interval de temperatura: The pump is designed to operate with liquid temperatures between 0°C and 35°C. Operating outside this range may damage the pump.
  4. Aturar la bomba: Disconnect the pump from the power supply. Close any necessary valves to prevent water backflow.
Diagram showing optimal flow rate and head for the Wiltec Pool Pump

Figura 3: Optimal Performance. This image highlights the pump's maximum head of 13 meters and maximum flow rate of 18,600 L/h, along with the recommended liquid temperature range of 0-35°C.

6. Manteniment

Regular maintenance ensures the longevity and efficient operation of your pool pump.

  • Neteja del prefiltre: The integrated pre-filter collects debris such as leaves, twigs, gravel, and hair. Regularly inspect and clean the pre-filter basket to maintain optimal flow and prevent pump strain. To clean, disconnect power, open the pre-filter lid, remove the basket, empty debris, and rinse thoroughly. Reassemble, ensuring the O-ring is properly seated and the lid is securely tightened.
  • Image showing the pre-filter of the Wiltec Pool Pump collecting debris

    Figura 4: Pre-filter Function. This image demonstrates how the pump's pre-filter effectively captures various types of debris, such as leaves, twigs, gravel, and hair, protecting the pump's internal components.

  • Inspecció de motors: Periodically check the motor for any unusual noises or excessive heat. The copper-wound motor is designed for stable operation and includes thermal overload protection.
  • Retall view of the Wiltec Pool Pump motor showing copper windings

    Figura 5: Robust Motor Design. This image provides a view of the pump's copper-wound motor, emphasizing its stable operation and built-in protection against overheating and overload.

  • Neteja general: Keep the exterior of the pump clean and free from dirt and debris.
  • Hivernització: In regions with freezing temperatures, drain the pump completely and store it in a dry, frost-free location during the off-season to prevent damage.

7. Solució De Problemes

Si teniu problemes amb la bomba, consulteu els següents problemes i solucions habituals:

ProblemaCausa possibleSolució
La bomba no arrencaNo power; tripped circuit breaker; motor overload protection activatedCheck power supply and connections; reset circuit breaker; allow motor to cool down if overheated.
Baix cabal d'aiguaClogged pre-filter basket; air leak in suction line; low water level in pool; clogged impellerClean pre-filter basket; check all suction line connections for leaks; ensure adequate pool water level; inspect impeller for blockages.
La bomba funciona però no flueix aiguaPump not primed; air lock; closed valve in suction linePrime the pump by filling the pre-filter with water; check for and release air locks; ensure all valves are open.
Sorolls o vibracions inusualsAir in system; debris in impeller; loose mountingCheck for air leaks and prime pump; clean impeller; tighten mounting bolts.

If problems persist after attempting these solutions, contact a qualified service technician or Wiltec customer support.

8. Especificacions

EspecificacióValor
FabricantWiltec
Número de model65829
Cabal (màx.)18,600 L/h
Wattage750 W
Cap Max13 metres
Volum de piscina recomanat74-110 m³
Dimensions del producte (L x A x A)58 x 24.7 x 36.7 cm
Pes de l'article10.25 kg
MaterialPlàstic
ColorBlau, Negre
Tipus de potènciaCordat
Rang de temperatura del líquid0-35°C

9. Garantia i Suport

Per obtenir informació sobre la garantia, assistència tècnica o consultes sobre el servei, poseu-vos en contacte amb el vostre distribuïdor o directament amb el fabricant. Conserveu el rebut de compra com a comprovant de compra.

A Certificate of Conformity is available for this product: Certificate of Conformity (PDF)

© 2026 Wiltec. Tots els drets reservats.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.