1. Introducció
The SINOTIMER SVP-977 is a three-in-one multi-function device designed for home usage, providing comprehensive protection against over-voltage, baix voltage, and over-current conditions in single-phase AC 230V, 50/60Hz electrical systems. It also features power monitoring capabilities, displaying voltage, current, and energy consumption (kWh) on an LCD screen. This device is primarily used for residential household box entry or for protecting distribution lines of single-phase electrical equipment. Its key function is to instantly cut off the power supply when abnormal voltage or current conditions occur, safeguarding connected electrical equipment from damage. Once the circuit voltage returns to normal, the protector automatically restores power.
Figure 1: SINOTIMER SVP-977 Adjustable Voltage Protectors (63A and 80A models)
2. Característiques
The SVP-977 offers a range of protective and monitoring features:
- Voltagpantalla electrònica (vol.)tagmesura e)
- Visualització actual (mesura actual)
- KWH display (energy measurement)
- Sobrevoltage protecció
- Baix voltage protecció
- Protecció contra sobreintensitat
- Adjustable over-voltagvalor de protecció
- Adjustable over-voltage valor de recuperació
- Adjustable over-voltagtemps d'acció de protecció electrònica
- Adjustable under-voltagvalor de protecció
- Adjustable under-voltage valor de recuperació
- Adjustable under-voltagtemps d'acció de protecció electrònica
- Adjustable over-current protection value
- Adjustable over-current protection action time
- Temps de retard de recuperació d'errors ajustable
- Adjustable delay time after power-on
- Selecció del mode de reinici
- Fault inquiry function
- Factory data reset option
- Temporary KWH reset function
- Cycle countdown timer
Figure 2: Model variants with and without backlight, 63A and 80A Max Load
3. Especificacions
| Paràmetre | Valor/Interval |
|---|---|
| Número de model | SVP-977 |
| Nom de marca | SINOTIMER |
| Tipus | Mini Circuit Breaker / Adjustable Voltage Protector |
| Font d'alimentació | 230VAC 50 / 60Hz |
| Voltage | 220 V |
| Càrrega màxima | 1~63A / 1~80A Adjustable (default: 63A/80A) |
| Sobrevoltagrang de valors de protecció electrònica | 221V~300V (default: 280V) |
| Sobrevoltage recuperació voltage gamma | 220V~299V (default: 250V) |
| Sobrevoltagtemps d'acció de protecció electrònica | 0.1s~10s (default: 0.1s) |
| Baix voltagrang de valors de protecció electrònica | 219V~150V (default: 160V) |
| Baix voltage recuperació voltage gamma | 151V~220V (default: 180V) |
| Baix voltagtemps d'acció de protecció electrònica | 0.1s~10s (default: 0.1s) |
| Over-current adjustment range | 1~63A / 1~80A (default: 63A/80A) |
| Rang d'acció de sobrecorrent | 0.1s~512s (default: 5.0s) |
| Temps de retard de recuperació | 2s~600s (default: 60s) |
| Temps de retard a l'encesa | 2s~255s (default: 2s) |
| Consum d'energia | <2W |
| Electric Machinery Life | 100,000 vegades |
| Pols | 2 pols |
| Dimensions | 36 mm (W) x 65 mm (D) x 85 mm (H) |
| Instal·lació | Carril DIN de 35 mm |
| Mostra | Pantalla LCD |
| Certificació | CE, RoHS |
| És un dispositiu intel·ligent | No |
Figura 3: Dimensions del producte
4. Instal·lació i cablejat
The SVP-977 is designed for 35mm DIN rail installation. Ensure the power supply is disconnected before attempting any installation or wiring. Follow the wiring diagram carefully to ensure correct and safe operation.
4.1. Esquema de cablejat
Figura 4: Diagrama de cablejat
4.2. Connection Points
- IN (L, N): Input terminals for Line and Neutral from the power source.
- OUT (L, N): Output terminals for Line and Neutral to the load (e.g., household appliances).
WARNING: All electrical work should be performed by a qualified electrician to prevent electric shock or damage to the device.
5. Operation and Parameter Settings
The SVP-977 features an LCD display for real-time monitoring of voltage, current, and kWh. Parameters for protection and recovery can be adjusted using the device's buttons.
5.1. Mètode de configuració
- Manteniu premut el botó SET button for 3 seconds to enter the parameter setting mode.
- Premeu contínuament el botó SET button to cycle through the adjustable parameters (P01, P02, P03, etc.).
- Utilitza el Amunt (▲) or BAIX (▼) botons per ajustar el valor del paràmetre que es mostra actualment.
- Once you have set all desired parameters, continue pressing SET until "END" appears on the display.
- Premeu SET one more time to save the settings and exit the configuration mode. The new settings will be active.
5.2. Adjustable Parameters
| Pas | Parameter (Code) | Descripció | Adjustment Range (Default) |
|---|---|---|---|
| 1 | Sobrevoltage protection value (P01) | Vol superiortage limit before tripping. | 221V~300V~OFF (280V) |
| 2 | Sobrevoltage recovery value (P02) | Voltage at which power is restored after an over-voltage esdeveniment. | 220V~299V (250V) |
| 3 | Sobrevoltage protection action time (P03) | Delay before tripping on over-voltage. | 0.1s~10s (0.1s) |
| 4 | Baix voltage protection value (P04) | Vol inferiortage limit before tripping. | 219V~150V~OFF (160V) |
| 5 | Baix voltage recovery value (P05) | Voltage at which power is restored after an under-voltage esdeveniment. | 151V~220V (180V) |
| 6 | Baix voltagtemps d'acció de protecció electrònica | Delay before tripping on under-voltage. | 0.1s~10s (0.1s) |
| 7 | Over-current adjustment range | Maximum current limit before tripping. | 1~63A / 1~80A (63A/80A) |
| 8 | Rang d'acció de sobrecorrent | Delay before tripping on over-current. | 0.1s~512s (5.0s) |
| 9 | Temps de retard de recuperació | Delay before automatic power restoration after a fault. | 2s~600s (60s) |
| 10 | Temps de retard a l'encesa | Delay before power is supplied after initial power-up. | 2s~255s (2s) |
| 11 | Temporary KWH reset | Resets the temporary energy consumption reading. | N/A |
| 12 | Restableix les dades de fàbrica | Restaura tota la configuració als valors predeterminats de fàbrica. | N/A |
5.3. Funcions de visualització
- Voltage (V): Displays the real-time voltage del circuit.
- Corrent (A): Displays the real-time current flowing through the circuit.
- Energia (kWh): Displays the accumulated energy consumption. This reading can be temporarily reset.
Figura 5: Frontal View with LCD Display
6. Manteniment
The SINOTIMER SVP-977 is designed for long-term, reliable operation with minimal maintenance. To ensure optimal performance and longevity:
- Mantenir net: Periodically wipe the device with a dry, soft cloth to remove dust and debris. Do not use liquid cleaners.
- Comproveu les connexions: Ensure all wiring connections remain tight and secure. Loose connections can lead to overheating or intermittent operation.
- Evitar l'exposició: Do not expose the device to direct sunlight, excessive moisture, or extreme temperatures.
Figura 6: lateral View with DIN Rail Clip
7. Solució De Problemes
If you encounter issues with your SVP-977, consider the following:
- El dispositiu no s'encén: Check the main power supply and ensure all wiring connections are correct and secure. Verify the input voltage is within the operational range.
- Frequent Tripping: Review your set protection values (over-voltage, baix voltage, over-current). They might be set too sensitively for your electrical environment. Adjust the delay times (action time, recovery delay) to prevent nuisance tripping.
- Lectures incorrectes: While the device is calibrated, significant discrepancies might indicate a wiring issue or a faulty unit. Ensure proper connections.
- Settings Not Saving: Ensure you press the SET button until "END" appears and then press it one more time to confirm and save the settings.
- No Automatic Recovery: Check the recovery delay time setting. If set to a long duration, the device will wait before restoring power.
If problems persist after checking these points, please consult a qualified electrician or contact customer support.
8. Consells d'usuari
- Placement in Circuit: The SVP-977 can be installed after a Residual Current Device (RCD) or Residual Current Breaker with Overcurrent protection (RCBO) for comprehensive circuit protection.
- Voltage Estabilització: This device is a protector, not a voltage stabilizer. It will cut off power if voltage goes outside the set limits, but it does not actively regulate or stabilize the voltage.
- Settings Retention: All configured settings are retained even after a power outage, so you do not need to reconfigure them every time power is lost.
- KWH Reset: The temporary kWh reading can be reset. Refer to the operation section for detailed instructions on navigating the settings menu.
- Recovery Delay: The device includes an adjustable recovery delay time (from 2 to 600 seconds) which is useful to prevent rapid cycling of power to appliances after a fault, allowing them to stabilize.
9. Garantia i Suport
For warranty information, technical support, or further assistance, please contact the SINOTIMER Official Store or your point of purchase. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format may also be available for download. You can find the official PDF document at: Manual d'usuari (PDF)