Kamoer UIP WIFI V2

Kamoer UIP WIFI V2 Peristaltic Pump User Manual

Model: UIP WIFI V2 | Brand: Kamoer

1. Introducció

The Kamoer UIP WIFI V2 Peristaltic Pump is an intelligent, high-precision fluid transfer device designed for various laboratory and industrial applications. Featuring a stepper motor, adjustable flow rate, quick tube change support, and multiple control interfaces (WIFI, RS485, Analog, Foot Switch), it offers reliable and precise fluid handling. This manual provides essential information for the safe and efficient operation and maintenance of your pump.

Kamoer UIP WIFI V2 Peristaltic Pump with digital display

Figure 1: Kamoer UIP WIFI V2 Peristaltic Pump

2. Informació de seguretat

Please read and understand all safety instructions before operating the pump. Failure to do so may result in injury or damage to the equipment.

  • Ensure the power supply matches the pump's requirements (AC 100-240V).
  • Do not operate the pump with damaged power cords or tubing.
  • Always wear appropriate personal protective equipment (PPE) when handling chemicals or liquids.
  • Avoid immersing the pump in water or other liquids.
  • Disconnect power before performing any maintenance or tube changes.
  • Assegureu-vos d'una ventilació adequada quan treballeu en espais tancats.
  • Keep the pump away from heat sources and direct sunlight.

3. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:

  • 1 × UIP WIFI V2 Peristaltic Pump
  • 1 × cable d'alimentació
  • 1 × Interruptor de peu
  • 1 × Quick junction terminal
  • 1 × Silicone tube
  • 1 × Screwdriver (for foot switch connection)
Standard fittings included with the Kamoer Peristaltic Pump

Figure 2: Standard Fittings

4. Especificacions

Atribut Valor
Número de model UIP WIFI V2
Nom de marca Kamoer
Font d'alimentació Electric (AC 100-240 V)
Tipus de motor Motor pas a pas
Teoria Bomba rotativa
Estructura Bomba peristàltica
Pressió Baixa pressió
Estàndard o no estàndard Estàndard
Control WIFI Only for Firmware Upgrade
Interfície d'IU Pantalla tàctil
Tota la vida Més de 6000H
Number of Rotors 3 rotors or 6 rotors
Capçal de bomba Single Head / Double Head
Temperatura 0 ~ 40 ℃
Humitat 0 ~ 80 ℃
Mida 140 * 231 * 180 mm
Pes net 4.8KG Double head, 4.3KG Single head
Origen Xina continental
Certificació CE, RoHS

Flow Rate Specifications

Capçal de bomba Tube ID:OD Interval de velocitat (RPM) Caudal (ml/min) Durada de la vida útil dels tubs Temperatura de treball de la canonada
KK1800 1.6mm 3 rotors 19#(2.4*5.6), 16#(3.2*6.4), 25#(4.8*8.0), 17#(6.4*9.6), 18#(7.9*11.1) 0.1-350 0.1-1500 Silicone 200H -60 ℃ ~ 200 ℃
KK1800 1.6mm 6 rotors 19#(2.4*5.6), 16#(3.2*6.4), 25#(4.8*8.0), 17#(6.4*9.6), 18#(7.9*11.1) 0.1-350 0.1-750 Silicone 200H -60 ℃ ~ 200 ℃
KK1800-T2.5 2.5mm 3 rotors 15#(4.8*9.8), 24#(6.4*11.4) 0.1-350 0.5-950 Silicone 200H -60 ℃ ~ 200 ℃

5. Configuració

5.1. Connexió de l'alimentació

  1. Assegureu-vos que la bomba estigui col·locada en una superfície estable i plana.
  2. Locate the power interface (2) and power switch (1) on the back of the pump.
  3. Connect the provided power cable to the power interface on the pump and then to a suitable AC 100-240V power outlet.
  4. Turn on the pump using the power switch (1). The screen should illuminate.
Back panel of Kamoer pump showing power switch, power interface, Interface A and Interface B

Figura 3: Interfícies del panell posterior

5.2. Connecting the Pump Tube

  1. Open the pump head by lifting the latch or turning the knob (refer to Figure 4).
  2. Carefully insert the silicone tube into the pump head, ensuring it is properly seated in the rollers.
  3. Close the pump head securely.
Close-up of pump head showing open and closed positions for tube replacement

Figure 4: Pump Head Open and Close Mechanism

5.3. Connecting the Foot Switch

The foot switch provides convenient hands-free operation.

  1. Take out one of the quick junction terminals from the package.
  2. Connect the orange wire of the foot switch to the 'Pedal' pin (pin 11) on Interface B.
  3. Connect the yellow wire of the foot switch to the 'Common terminal' pin (pin 12) on Interface B.
  4. Use the provided screwdriver to tighten the screws on the terminal to secure the wires.
  5. Plug the quick junction terminal into Interface B on the back of the pump.
  6. On the pump's touch screen, navigate to Sistema > Pedal.
  7. Toggle the 'ON' switch to enable pedal control.
  8. Select the desired trigger type (e.g., Falling edge trigger).
Diagram of Interface A and Interface B pinouts with foot pedal control highlighted

Figure 5: Interface B Pinout for Foot Switch

6. Instruccions de funcionament

The UIP WIFI V2 pump offers various operating modes and calibration features via its touch screen interface.

Video 1: Kamoer Peristaltic Pump Operation Demonstration

6.1. Flow Rate Calibration

Accurate calibration ensures precise fluid dispensing.

  1. From the main screen, navigate to the Calibració pestanya.
  2. Feu clic a Omplir button to fill the pump tube with the liquid.
  3. Once the tube is filled, click Atureu-vos.
  4. Empty the measuring cylinder or beaker.
  5. Feu clic a Calibrar button. The pump will run for a default time (e.g., 60 seconds at 100 RPM).
  6. Once the calibration time ends and the pump automatically stops, measure the volume of liquid dispensed into the cylinder.
  7. Input the measured liquid volume into the pump's interface.
  8. Feu clic Fet per completar el calibratge.

6.2. Continuity Mode

Continuity mode allows for continuous fluid transfer at a set flow rate.

  1. From the main screen, click on Mode.
  2. Seleccioneu Continuïtat from the running mode options.
  3. Adjust the desired flow rate using the + i - buttons, or click on Caudal (ml/min) to enter the value directly.
  4. Feu clic Comença to begin continuous pumping.

6.3. Ration Mode

Ration mode allows for dispensing specific volumes of liquid with customizable parameters.

  1. From the main screen, click on Mode.
  2. Seleccioneu Ració from the running mode options.
  3. Feu clic Edita to set the allocation parameters:
    • Volum (ml): Set the volume to dispense per cycle.
    • Caudal (ml/min): Set the flow rate for dispensing.
    • Pause Time (s): Set the pause duration between cycles.
    • Compte: Set the number of dispensing cycles.
    • Mode de cicle: Choose between Auto or Semi-Auto.
  4. Adjust parameters according to your requirements.
  5. Feu clic Comença to begin the programmed dispensing cycles.
Kamoer pump touch screen interface showing various modes and settings

Figure 6: Touch Screen Interface

7. Manteniment

Regular maintenance ensures the longevity and optimal performance of your Kamoer Peristaltic Pump.

7.1. Substitució de tubs

Peristaltic pump tubes are wear-and-tear parts and should be replaced regularly depending on usage and liquid type. Refer to the 'Connecting the Pump Tube' section for instructions on how to open the pump head and replace the tube.

7.2. Neteja

  • Netegeu l'exterior de la bomba amb un drap suau iamp tela.
  • No utilitzeu netejadors abrasius ni dissolvents.
  • Ensure no liquid enters the internal components of the pump.
  • Clean the pump head and rollers regularly to prevent residue buildup.

7.3. Emmagatzematge

When not in use, store the pump in a clean, dry, and cool environment, away from direct sunlight and corrosive substances.

8. Solució De Problemes

Si teniu problemes amb la bomba, consulteu els següents problemes i solucions habituals:

Problema Causa possible Solució
La bomba no s'encén No power, power cable loose, power switch off Check power connection, ensure power switch is ON.
No fluid flow or inconsistent flow Pump tube kinked, incorrect tube size, pump head not closed properly, calibration error Check tube for kinks, ensure correct tube size is used, verify pump head is securely closed, re-calibrate flow rate.
La bomba fa un soroll inusual Worn out tube, foreign object in pump head, motor issue Replace pump tube, inspect pump head for obstructions, contact support if noise persists.
La pantalla tàctil no respon Temporary software glitch, power issue Restart the pump. If issue persists, contact support.

9. Consells d'usuari

  • Tubing Selection: If your liquid is viscous or corrosive, it is recommended to choose BPT tubing for better chemical stability and longer life. Silicone tubing is generally suitable for neutral liquids.
  • Calibració regular: For applications requiring high precision, perform flow rate calibration regularly, especially after changing tubing or if there are significant changes in liquid properties.
  • Prevent Kinks: Always ensure the tubing is installed without any kinks or sharp bends to maintain consistent flow and prevent damage to the tube.
  • Interface B: Interface B supports current analog, direction, and foot control. This allows for flexible integration into automated systems or for hands-free operation.

10. Garantia i Suport

For any technical assistance, warranty claims, or further inquiries, please contact the Kamoer Global Store customer support. Ensure you have your product model and purchase details ready when contacting support.