KETOTEK KT3200

KETOTEK KT3200 Digital Plug-in Thermostat Timer

Manual d'instruccions

1. Introducció

The KETOTEK KT3200 is a versatile digital plug-in thermostat designed for precise temperature control and timing functions. It allows users to set specific start and stop temperatures for both heating and cooling equipment. Additionally, it features a time function for independent day and night temperature control, making it ideal for various applications.

This device is widely used in intelligent control systems for heating, refrigeration, brewing, reptile habitats, aquaculture, greenhouses, and general home life.

Davant view of the KT3200 thermostat with attached temperature sensor.
KT3200 Digital Plug-in Thermostat with temperature sensor.

2. Producte acabatview

The KT3200 features a clear digital display and intuitive button controls for easy operation. The device is available in various plug types to suit different regional standards.

Labeled diagram of the KT3200 control panel buttons and output indicator.
Control Panel and Button Functions:
- Output work indicator: Lights up when output is active.
- M (Switch working mode): Cycles through M1, M2, M3 modes.
- + (Increase value): Augmenta el valor seleccionat.
- OK (Select / C°/F° key): Confirms selection or switches temperature unit (press for 3s).
- - (Decrease key): Decreases the selected value.
- ↶ (Back / Reset key): Returns to previous screen or resets (press for 3s).
Dimensions of the KT3200 thermostat and its temperature sensor probe.
Approximate dimensions: 5.8cm (width) x 11.8cm (height) x 3.2cm (depth). Sensor cable length: 290cm. Sensor probe dimensions: 2.4cm (length) x 0.5cm (diameter).
Examples of KT3200 thermostat applications: room heating, incubator, aquarium, greenhouse.
Common applications include room temperature control, incubators, aquariums, and greenhouses.

3. Especificacions

CaracterísticaEspecificació
ModelKT3200
MarcaKETOTEK
Font d'alimentació100 ~ 250VAC 50 / 60Hz
Interval de control de temperatura-40 ℃ ~ 120 ℃ / -72 ℉ ~ 176 ℉
Unitats de temperatura℃/℉ Switchable
Configuració de l'hora0-24h / Temporitzador de cicle diari
Control de precisió±1 ℃ / ±1 ℉
SensorNTC10K/B3950
Output (EU/UK/FR/AU)Max 16A/230V (Inductive load < 2A, Resistance load < 14A)
Sortida (EUA)Max 15A/120V (Inductive load < 2A, Resistance load < 14A)
Longitud del cable3M
Mida de la pantalla1.9 polzades i menys
CertificacióCE
FuncionsReset, Temperature Calibration, Memory (power off)
Modes de treballM1 (Temperature Control), M2 (Temperature Control + Timer), M3 (Timer Only)

4. Advertències de seguretat

Please read and adhere to these safety warnings to prevent injury or damage to the device:

  1. Before using this unit, carefully inspect the plastic casinComproveu si hi ha signes de danys. No utilitzeu el dispositiu si sembla danyat.
  2. The relay has a maximum capacity of 16A. For resistance loads, ensure the connected appliance draws less than 14A. For inductive loads, ensure it draws less than 2A. Exceeding these limits can cause damage or fire.
  3. Do not operate this unit in environments containing explosive gases, excessive steam, or high dust concentrations.
  4. Keep the device out of reach of children and do not allow them to operate it.
  5. Do not attempt to disassemble or repair the device yourself. Refer to qualified personnel for servicing.

5. Configuració

  1. Desembalar: Carefully remove the KT3200 thermostat and its accessories from the packaging.
  2. Inspeccionar: Check the device for any visible damage as per the safety warnings.
  3. Connecta el sensor: Plug the 3-meter temperature sensor into the designated port on the thermostat.
  4. Encès: Insert the KT3200 into a suitable power outlet matching your regional plug type (e.g., EU, UK, FR, AU, US). Ensure the connected appliance's power requirements do not exceed the thermostat's output limits.
  5. Initial Clock Setting (M2/M3 Modes): If you plan to use M2 (Temperature Control + Timer) or M3 (Timer Only) modes, you will need to set the current time after powering on, especially after a power outage.
KT3200 thermostat with an EU Type plug.
Example: KT3200 with EU Type plug.
KT3200 thermostat with a US Type plug.
Example: KT3200 with US Type plug.
KT3200 thermostat with a UK Type plug.
Example: KT3200 with UK Type plug.
KT3200 thermostat with an AU Type plug.
Example: KT3200 with AU Type plug.
KT3200 thermostat with an FR Type plug.
Example: KT3200 with FR Type plug.

6. Modes de funcionament

The KT3200 offers three distinct working modes, selectable by pressing the 'M' button:

Acabatview of the three working modes (M1, M2, M3) displayed on the KT3200 screen.
Visual representation of M1, M2, and M3 display modes.

6.1. M1 TC: Temperature Control Mode

In this mode, the thermostat controls the connected device based on a single set of start and stop temperatures.

  • Configuració: Set your desired start and stop temperatures using the '+' and '-' buttons, then confirm with 'OK'.
  • Mode de calefacció: To operate in heating mode, set the start temperature to be menys que the stop temperature. The device will turn on when the measured temperature drops below the start temperature and turn off when it reaches the stop temperature.
  • Mode de refrigeració: To operate in cooling mode, set the start temperature to be més gran que the stop temperature. The device will turn on when the measured temperature rises above the start temperature and turn off when it drops to the stop temperature.

6.2. M2 TC+Timer: Day/Night Temperature Control

This mode allows for two different temperature control programs (TC1 and TC2) to run during specified day and night periods within a 24-hour cycle.

  • Configuració: Set the current clock time, then define Time1 (start of day period) and Time2 (start of night period). Also, set the start and stop temperatures for TC1 (Day program) and TC2 (Night program).
  • Funcionament: During the Daytime (from Time1 to Time2), the device will run the TC1 program. During the Night time (from Time2 to Time1), it will run the TC2 program.
Detailed diagram of the M2 temperature control + timer mode, showing day/night temperature settings.
M2 mode diagram illustrating TC1 (Day) and TC2 (Night) temperature ranges and their 24-hour cycle.

6.3. M3 Timer: 2 Timer Period Timer Only

This mode functions purely as a timer, turning the connected device on and off at specified times.

  • Configuració: Set the current clock time, then define Time1 (ON time) and Time2 (OFF time).
  • Funcionament: The output will be ON from Time1 to Time2. The output will be OFF from Time2 to Time1.

7. Funció de memòria

  • All configured data, except for the current clock time, will be saved automatically after a power failure.
  • The clock time will need to be reset manually when the device is powered on again after an outage.
  • If the KT3200 was operating in M1 mode before a power failure, it will automatically resume operation in M1 mode with its saved temperature settings once power is restored.
  • If the KT3200 was operating in M2 or M3 mode before a power failure, you will need to reset the clock time first upon power restoration for these modes to function correctly.

8. Consells d'usuari

  • Configuració de temperatura flexible: The KT3200 allows for a wide range of temperature settings, including scenarios where the turn-on temperature is higher than the turn-off temperature (for cooling) or vice-versa (for heating). For example, you can set it to turn on at 50°C and turn off at 30°C.
  • Room Heating: This thermostat is well-suited for controlling room heaters to maintain a desired ambient temperature by automatically switching the heater on and off.
  • Capacitat de càrrega: Be mindful of the maximum load. For EU/UK/FR/AU plugs, the maximum is 16A/230V (resistance load < 14A, inductive load < 2A). For US plugs, it's 15A/120V (resistance load < 14A, inductive load < 2A). Ensure your appliance's wattage is within these limits.
  • Lectures estables: The temperature sensor is designed to provide stable readings, minimizing temperature fluctuations during operation.

9. Solució De Problemes

  • Unstable Temperature Readings: If the displayed temperature fluctuates erratically, first check the connection of the temperature sensor. Ensure it is securely plugged in and that the sensor probe itself is not damaged.
  • El dispositiu no s'encén/s'apaga: Verify that the start and stop temperatures are correctly set for your desired heating or cooling mode (M1). In M2/M3 modes, ensure the clock is set correctly and the timer periods are configured as intended. Check if the connected appliance is functioning correctly.
  • No Output After Power Outage (M2/M3 Modes): If the device was in M2 or M3 mode and experienced a power outage, the clock needs to be reset. Reset the clock, and the device should resume its programmed operation.
  • Protecció de sobrecàrrega: If the device unexpectedly shuts off, check the load connected to it. Ensure it does not exceed the maximum amperage for resistance (14A) or inductive (2A) loads.

10. Contingut del paquet

Your KETOTEK KT3200 package should include:

  • 1 x KT3200 Thermostat Timer with 3m Temperature Sensor
  • 1 x manual d'instruccions
  • 1 x Caixa de producte

11. Garantia i Suport

The KETOTEK KT3200 comes with a 6-month warranty from the date of purchase.

  • Devolucions: If you are not satisfied with your item, you may return it within 14 days for a replacement or a refund. Please contact customer support before initiating a return.
  • Defective within 3 Months: If the item is found to be defective within 3 months of purchase, a replacement will be sent without extra charge, or a full refund will be issued upon receipt of the defective item.
  • Defective after 3 Months: If the item becomes defective after 3 months but within the warranty period, you can still send it back for a replacement. However, you will be responsible for the additional shipping fees.

For any support inquiries, please contact KETOTEK customer service.

Documents relacionats - KT3200

Preview Ketotek KT3200 Plug-in Thermostat User Manual
Instruction manual for the Ketotek KT3200 Plug-in Thermostat, a Day/Night Temperature Controller. Details operation modes (M1 TC, M2 TC+Timer, M3 Timer), temperature calibration, reset functions, and memory features.
Preview Manual d'instruccions del termòstat endollable KETOTEK KT3100 EUA
Apreneu a utilitzar el termòstat endollable KETOTEK KT3100 US. Aquest manual tracta el control de la temperatura (calefacció/refrigeració), els modes de temporització (cicle, compte enrere), el calibratge i les especificacions per a la gestió intel·ligent de la temperatura.
Preview Manual d'instruccions del termòstat endollable KETOTEK KT3100 EUA
Apreneu a utilitzar el termòstat endollable KETOTEK KT3100 US, un controlador de temperatura versàtil per a aplicacions de calefacció, refrigeració i temporització en llars, hivernacles i aqüicultura. Aquest manual tracta la configuració, el control de temperatura, els modes de temporització i les especificacions.
Preview KETOTEK Thermostat Troubleshooting Guide | Resolve Common Issues
Find solutions for common KETOTEK thermostat problems including inaccurate temperature, power issues, error codes, and timing setup. Learn about calibration and warranty support.
Preview Manual d'instruccions del controlador de temperatura i humitat KETOTEK KT100 Fahrenheit
Manual d'instruccions complet per al controlador de temperatura i humitat KETOTEK KT100 Fahrenheit, que detalla les especificacions, el cablejat, les instruccions d'operació i els procediments de calibratge per al control de temperatura i humitat.
Preview Manual d'usuari i guia d'instal·lació del termòstat intel·ligent WiFi KETOTEK KTF017802
Comprehensive user manual and installation guide for the KETOTEK KTF017802 Smart WiFi Thermostat. Learn how to install, configure, and operate your thermostat for efficient heating control, including app integration with Alexa and Google Assistant.