KERUI D2

KERUI D2 Wireless Door/Window Alarm System User Manual

Model: D2

1. Introducció

The KERUI D2 Wireless Door/Window Alarm System is a versatile security device designed to protect your home, garage, or office. This system functions as an alarm host, capable of detecting unauthorized entry through doors and windows. It can also be integrated with additional wireless sensors such as PIR motion detectors, smoke detectors, and emergency buttons, providing a comprehensive security solution. The alarm emits a loud 120dB sound upon activation to deter intruders.

KERUI D2 main unit, magnetic strip, and remote controls, showing 120dB alarm.
KERUI D2 main unit, magnetic strip, and remote controls, showing 120dB alarm.
KERUI D2 as an alarm host, showing PIR sensor, door sensor, and remote control interaction.
KERUI D2 as an alarm host, showing PIR sensor, door sensor, and remote control interaction.

2. Contingut del paquet

Si us plau, comproveu el paquet per veure si hi ha els elements següents:

  • 1 x KERUI D2 Main Alarm Unit (Host)
  • 1 x Magnetic Strip for Door/Window Sensor
  • 1 x comandament a distància
  • 2 piles AAA de 1.5 V
  • Double-sided Adhesive Pads
  • Manual d'usuari (aquest document)
Video: Unboxing and basic operation demonstration of the KERUI D2 alarm system.

3. Especificacions

CaracterísticaEspecificació
Número de modelD2 (KR-D2)
Nom de marcaKERUI
Tipus d’alarmaL'Alarma
Configuració del kitSensor de porta
Dimensions (unitat principal)96 x 43 x 11 mm
Interfície de comunicacióSense fil
Arming TypeFR Remote-controller
Màxim de comandaments a distància compatibles20
Detectors màxims compatibles40
Número de sortida1
Font d'alimentació2 piles AAA de 1.5 V
Voltage3V
Corrent d'espera<10 mA
Corrent de treball> 70 mA
CertificacióCE
Nivell de so d'alarma120 dB
PIR Sensor Detection Range (compatible)8-12 meters / 110 degrees
Wireless Distance (open area, compatible)300 metres
Wireless Transmitting Frequency (compatible)433 MHZ (+ 75 KHZ)
Material de closcaPlàstics ABS
Product dimensions of the KERUI D2 main unit and magnetic strip.
Product dimensions of the KERUI D2 main unit and magnetic strip.

4. Configuració

4.1 Instal·lació de la bateria

  1. Gently slide open the back cover of the main alarm unit.
  2. Introduïu dues (2) piles AAA d'1.5 V, assegurant-vos de la polaritat correcta (+/-).
  3. Tanqueu bé la tapa del compartiment de la bateria.
Steps for battery installation and attaching the magnetic sensor to a door or window.
Steps for battery installation and attaching the magnetic sensor to a door or window.
Close-up of the battery compartment showing two AAA batteries installed.
Close-up of the battery compartment showing two AAA batteries installed.

4.2 Mounting the Door/Window Sensor

  1. Identify a clean, dry, and stable surface on your door/window frame (for the main unit) and the door/window itself (for the magnetic strip). Avoid unstable or easily broken surfaces.
  2. Remove the protective film from the double-sided adhesive pads.
  3. Attach one adhesive pad to the back of the main alarm unit and the other to the back of the magnetic strip.
  4. Carefully align the main alarm unit and the magnetic strip. They should be mounted parallel to each other, with the alignment marks facing each other, and be no more than 1 cm apart when the door/window is closed.
  5. Press firmly for a few seconds to ensure secure adhesion.
  6. Locate the power switch on the side of the main unit and slide it to the 'ON' position to activate the sensor.
Detailed installation steps for the KERUI D2 door sensor.
Detailed installation steps for the KERUI D2 door sensor.
Installation notes for various locations including doors, windows, and drawers.
Installation notes for various locations including doors, windows, and drawers.

4.3 Pairing Remote Controls and Additional Detectors

The KERUI D2 system supports up to 20 remote controls and 40 additional detectors (PIR sensors, smoke detectors, etc.).

  1. Ensure the main alarm unit is powered on.
  2. Press the 'Setting button' on the side of the main alarm unit. The indicator light will typically flash or change color, indicating it's in pairing mode.
  3. While the main unit is in pairing mode, activate the remote control (e.g., press an arm/disarm button) or trigger the additional detector (e.g., wave hand in front of PIR sensor).
  4. The main unit will emit a confirmation sound or the indicator light will change again to confirm successful pairing.
  5. Repeat for all additional remote controls and detectors.
Diagram showing the linkage alarm feature with a PIR sensor.
Diagram showing the linkage alarm feature with a PIR sensor.
Diagram showing the linkage alarm feature with another door sensor.
Diagram showing the linkage alarm feature with another door sensor.

5. Instruccions de funcionament

5.1 Armar el sistema

To arm the system, press the 'Arm' button (often represented by a closed padlock or similar icon) on your remote control. The main unit's indicator light may flash or change color to confirm the system is armed.

Remote control arm/disarm feature, showing a person entering a door.
Remote control arm/disarm feature, showing a person entering a door.

5.2 Desarmament del sistema

To disarm the system, press the 'Disarm' button (often represented by an open padlock or similar icon) on your remote control. The main unit's indicator light will confirm the system is disarmed.

Image of the remote control used for arming and disarming the alarm system.
Image of the remote control used for arming and disarming the alarm system.

5.3 Alarm Trigger

When the system is armed, an alarm will be triggered if:

  • The magnetic strip separates from the main door/window sensor unit (e.g., a door or window is opened).
  • A paired PIR motion detector senses movement.
  • Any other paired detector (e.g., smoke detector, emergency button) is activated.

Upon trigger, the main unit will emit a loud 120dB alarm sound and its LED lights will flash for 1 second.

Diagram showing the 120dB alarm sounding when a door is opened.
Diagram showing the 120dB alarm sounding when a door is opened.
The alarm unit with flashing LED lights when triggered.
The alarm unit with flashing LED lights when triggered.

6. Manteniment

6.1 Substitució de la bateria

The main alarm unit is powered by two AAA 1.5V batteries. When the batteries are low, the unit will emit a 'du du du...' sound as a reminder. To replace the batteries:

  1. Slide open the back cover of the main alarm unit.
  2. Traieu les piles velles.
  3. Insert two new AAA 1.5V batteries, observing correct polarity.
  4. Tanqueu la tapa del compartiment de la bateria.
Image illustrating the low battery reminder sound and the use of AAA batteries.
Image illustrating the low battery reminder sound and the use of AAA batteries.

6.2 Neteja

To clean the device, gently wipe the exterior with a soft, dry cloth. Do not use liquid cleaners or abrasive materials, as these may damage the unit.

7. Solució De Problemes

ProblemaCausa possibleSolució
Alarm does not sound when door/window opens.1. System is not armed.
2. Batteries are low or depleted.
3. Magnetic sensor parts are not properly aligned or too far apart.
1. Arm the system using the remote control.
2. Replace the AAA batteries.
3. Ensure the main unit and magnetic strip are aligned and within 1 cm when the door/window is closed.
Falses alarmes.1. Magnetic sensor parts are loose or misaligned.
2. Unstable mounting surface.
3. (If using PIR) Environmental factors like drafts or pets.
1. Re-secure and re-align the magnetic sensor parts.
2. Mount the device on a stable surface.
3. Adjust PIR sensor placement or sensitivity if applicable.
El comandament a distància no funciona.1. Remote control battery is depleted.
2. Remote control is not paired with the main unit.
1. Replace the remote control battery (typically a button cell).
2. Re-pair the remote control following the pairing instructions in Section 4.3.
Low battery reminder sounds frequently.Batteries are nearing end of life.Replace the AAA batteries in the main unit.

8. Consells d'usuari

  • Col·locació òptima: For best performance, ensure the main alarm unit and its magnetic strip are mounted securely and remain within 1 cm of each other when the protected entry point is closed.
  • Proves periòdiques: Periodically test your alarm system by arming it and then opening the protected door or window to ensure it functions correctly.
  • Durada de la bateria: While the device offers long standby time, it's good practice to have spare AAA batteries on hand for quick replacement when the low battery alert sounds.
  • Expandabilitat: Avançanttage of the system's expandability by adding PIR motion sensors for larger areas or smoke detectors for enhanced safety.

9. Garantia i Suport

Per a qualsevol consulta relacionada amb el producte, assistència tècnica o reclamació de garantia, poseu-vos en contacte directament amb el venedor o el fabricant. Conserveu el rebut de compra com a comprovant de compra.