1. Introducció
The Lae MTR12 is a special intelligent digital temperature controller designed for precise temperature management. This thermostat is suitable for various applications requiring accurate temperature monitoring and control, particularly for cooling systems. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your MTR12 controller.
2. Especificacions
| Paràmetre | Valor |
|---|---|
| Model | MTR12 |
| Temperature Sensor (T1) | NTC type, -50°C to +150°C |
| Output 1 (Out1) | 8(3)A 240V~, Cooling function |
| Power Supply (PWR) | 230V~ ±10% 50/60Hz, 2W |
| Categoria de subministraments de bricolatge | Elèctric |
| Origen | Xina continental |
| Certificació | CAP |
3. Producte acabatview
The MTR12 temperature controller features a clear digital display and intuitive controls for setting and monitoring temperatures. It comes with a temperature sensor, mounting clips, and a gasket for installation.



4. Instal·lació
The MTR12 controller is designed for panel mounting. Ensure the installation location is free from excessive vibration, moisture, and extreme temperatures outside the operating range.
4.1 Muntatge
- Cut a rectangular opening in the panel according to the controller's dimensions.
- Introduïu el controlador a l'obertura des de la part frontal.
- Use the provided mounting clips to secure the controller from the rear of the panel.
- Apply the rubber gasket around the front bezel for a snug fit and to provide some sealing against dust/moisture.
4.2 Col·locació del sensor
Connect the NTC temperature sensor to the designated terminals. Position the sensor in the area where temperature measurement and control are required. Ensure the sensor cable is routed away from power lines to avoid interference.
5. Esquema de cablejat
Refer to the diagram below for correct electrical connections. All wiring should be performed by a qualified electrician and in accordance with local electrical codes.

Connexions de terminals:
- Terminals 1, 2, 3 (Out1): Relay output for the cooling device.
- 1: Common (C)
- 2: Normally Open (NO)
- 3: Normally Closed (NC)
- Terminals 4, 5 (PWR): Power supply input (230V~ ±10% 50/60Hz).
- Terminals 11, 12 (T1): Input for the NTC temperature sensor.
WARNING: Ensure power is disconnected before making any wiring connections to prevent electric shock.
6. Funcionament
The MTR12 controller features a digital display and four control buttons: SET, HYS, Up Arrow, and Down Arrow.
6.1 Basic Temperature Setting
- Premeu el botó SET botó una vegada per view la temperatura de consigna actual.
- While the setpoint is displayed, use the Fletxa amunt or Fletxa cap avall botons per ajustar la temperatura desitjada.
- Premeu SET again to confirm the new setpoint and exit the setting mode.
6.2 Hysteresis Setting
Hysteresis (HYS) defines the temperature difference between the turn-on and turn-off points of the output relay, preventing rapid cycling of the cooling device.
- Manteniu premut el botó HYS button to enter the hysteresis setting mode.
- Utilitza el Fletxa amunt or Fletxa cap avall buttons to adjust the hysteresis value.
- Allibera el HYS botó per desar la configuració.
Consult the full product manual (if available) for advanced parameter settings and calibration procedures.
7. Manteniment
The MTR12 temperature controller requires minimal maintenance. Regular checks can ensure its longevity and accurate performance.
- Neteja: Wipe the display and casinNetegeu amb un drap suau i sec. No utilitzeu productes de neteja abrasius ni dissolvents.
- Connexions: Periodically check all electrical connections for tightness and signs of corrosion.
- Sensor: Ensure the temperature sensor is clean and free from debris that could affect its accuracy. Verify its placement is secure.
- Ventilació: Ensure adequate airflow around the controller if installed in an enclosed space to prevent overheating.
8. Solució De Problemes
If you encounter issues with your MTR12 controller, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla està en blanc | No hi ha alimentació o cablejat incorrecte. | Check power connections to terminals 4 and 5. Ensure the power source is active. |
| Lectura de temperatura incorrecta | Faulty sensor, incorrect sensor wiring, or sensor placed improperly. | Verify sensor connections to terminals 11 and 12. Check sensor for damage. Reposition sensor if necessary. |
| Cooling device not activating/deactivating | Incorrect setpoint/hysteresis, faulty relay, or wiring issue to the cooling device. | Check setpoint and hysteresis settings. Verify wiring to the cooling device (terminals 1, 2, 3). Test the cooling device independently. |
| Controller not responding to button presses | Internal fault or temporary software glitch. | Try power cycling the device (turn off, wait 30 seconds, turn on). If the problem persists, contact support. |
9. Consells d'usuari
- For optimal performance, ensure the temperature sensor is placed in a location that accurately represents the temperature of the area you wish to control, away from direct heat sources or drafts.
- When setting the hysteresis, consider the thermal inertia of your system. A smaller hysteresis provides tighter control but can lead to more frequent cycling of the cooling device, potentially reducing its lifespan.
- Always double-check wiring before applying power to prevent damage to the controller or connected equipment.
10. Garantia i Suport
For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your vendor. Keep your purchase receipt as proof of purchase.