1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the Zusen YJ2N-LY series high power intermediate relay. The YJ2N-LY is a general-purpose voltage relay designed for various control applications, featuring two groups of high-power contacts and an action indicator light. Please read this manual thoroughly before using the product to ensure safe and correct operation.
2. Informació de seguretat
- Always disconnect power before installing, wiring, or performing maintenance on the relay.
- Ensure that the relay's voltagLes classificacions e i actuals coincideixen amb els requisits de l'aplicació.
- Wiring should be performed by qualified personnel in accordance with local electrical codes and regulations.
- Avoid exposing the relay to extreme temperatures, high humidity, or corrosive environments.
- Do not attempt to disassemble or modify the relay, as this may void the warranty and pose safety risks.
- The relay is sealed; do not open the casing.
3. Producte acabatview
The Zusen YJ2N-LY is an 8-pin intermediate relay designed for general purpose use. It features two changeover (2C) contacts made of Ag alloy, capable of handling high power loads. An integrated indicator light provides visual feedback on the relay's operational status. This series is available for a wide range of AC and DC coil voltages.

Figure 3.1: Zusen YJ2N-LY Relay with Socket (Overall View)

Figure 3.2: Zusen YJ2N-LY Relay (Close-up)

Figure 3.3: Zusen YJ2N-LY Relay (Side View)
4. Especificacions
| Característica | Especificació |
|---|---|
| Número de model | YJ2N-LY |
| Teoria | Voltage relleu |
| Ús | Finalitat General |
| Funció de protecció | Segellat |
| Configuració de contactes | 2C (2 Changeover contacts) |
| Contact Mechanism | Single contact |
| Material de contacte | Aliatge Ag |
| Càrrega nominal (resistiva) | AC110V 10A; DC24V 10A |
| Rated Load (Inductive, cos=0.4; L/R=7ms) | AC110V 7.5A; DC24V 5A |
| Rated Energizing Current | 10A |
| Maximum Contact Voltage | AC250V; DC125V |
| Contact Current Maximum Value | 10A |
| Maximum Switching Capacity (Resistive) | 100 VA 240 W |
| Maximum Switching Capacity (Inductive) | 440 VA 96 W |
| Resistència al contacte | Below 100mΩ |
| Temps d'acció | Menys de 20 ms |
| Restablir l'hora | Menys de 20 ms |
| Maximum Switching Frequency (Mechanical) | 18,000 times/hour |
| Maximum Switching Frequency (Rated Load) | 24,000 times/hour |
| Resistència d'aïllament | Above 1000MΩ |
| Resistir voltage (Coil and Contact) | AC2,000V 50/60Hz 1min |
| Resistir voltage (Heteropolar Contacts) | AC2,000V 50/60Hz 1min |
| Resistir voltage (Same Pole Contacts) | AC1,000V 50/60Hz 1min |
| Vibration (Durability) | 10~55~10Hz; double ampalçada 1.0 mm |
| Vibració (mal funcionament) | 10~55~10Hz; double ampalçada 1.0 mm |
| Shock (Durability) | 1,000m/s² (approx. 100G) |
| Xoc (mal funcionament) | 200m/s² (approx. 20G) |
| Durability (Mechanical) | 50,000,000 vegades |
| Durability (Electrical) | 500,000 vegades |
| Ambient Temperature (Standard) | -55°C ~ 70°C (no freezing/condensation) |
| Ambient Temperature (With Indicator) | -40°C ~ 70°C (no freezing/condensation) |
| Ambient de funcionament Humitat | 5~85% HR |
| Available Coil Voltages | DC: 6V, 12V, 24V, 36V, 48V, 110V, 220V AC: 110V, 220V, 380V |
5. Instal·lació i configuració
The YJ2N-LY relay is designed for easy installation, typically into a compatible 8-pin relay socket. Ensure the socket is securely mounted before inserting the relay.
5.1 Diagrama de pins
Refer to the bottom view diagram for correct pin identification and wiring. The coil terminals are typically pins 7 and 8. The contact pins are numbered 1 through 6, forming two independent changeover contact sets.

Figure 5.1: Zusen YJ2N-LY Relay Pinout Diagram (Bottom View)
5.2 Instruccions de cablejat
- Identify Coil Terminals: Pins 7 and 8 are the coil terminals. Apply the rated control voltage (AC or DC, as per your relay model) across these pins to energize the relay. For DC models, ensure correct polarity if indicated (e.g., 7(-) and 8(+)).
- Identify Contact Terminals: The relay has two sets of changeover contacts. Each set consists of a Common (C), Normally Open (NO), and Normally Closed (NC) terminal. Refer to the specific pin numbering on your relay for exact assignments (e.g., 1-2-3 for one set, 4-5-6 for the other).
- Connectar càrrega: Connect your controlled circuit's load to the appropriate contact terminals (NO or NC) and the common terminal.
- Connexions segures: Ensure all wire connections are tight and properly insulated to prevent short circuits or loose connections.
- Insert Relay: Carefully align the relay pins with the socket and push firmly until it is fully seated.

Figure 5.2: Zusen YJ2N-LY Relay Bottom View (Pins)
6. Funcionament
Once the relay is correctly installed and wired, apply the specified control voltage to the coil terminals (pins 7 and 8). When the coil is energized, the internal contacts will switch state (Normally Open contacts will close, Normally Closed contacts will open). The integrated indicator light will illuminate when the coil is energized, providing visual confirmation of the relay's active state. When the control voltage is removed, the coil de-energizes, and the contacts return to their original state.
7. Manteniment
The Zusen YJ2N-LY relay is a sealed unit and requires minimal maintenance. However, periodic inspection is recommended to ensure optimal performance and longevity.
- Inspecció visual: Regularly check the relay and its socket for any signs of physical damage, discoloration, or loose connections.
- Neteja: If dust or debris accumulates on the relay or socket, gently clean it with a dry, soft cloth. Do not use solvents or abrasive cleaners.
- Contact Integrity: While the contacts are sealed, ensure the load current does not exceed the rated values to prevent premature wear or welding of contacts.
- Condicions ambientals: Verifiqueu que l'entorn operatiu es mantingui dins dels rangs de temperatura i humitat especificats.
8. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Relay does not energize (no click, indicator light off) | Sense control voltage to coil, incorrect coil voltage, faulty wiring, damaged coil. | Comprovar control voltage supply. Verify coil voltage matches relay specification. Inspect wiring for breaks or loose connections. Replace relay if coil is damaged. |
| Relay energizes but contacts do not switch (or switch intermittently) | Excessive load, worn contacts, faulty contacts. | Ensure load current is within rated limits. Replace relay if contacts are worn or faulty. |
| Indicator light does not illuminate when coil is energized | Faulty indicator light, incorrect coil voltage. | Verifica el volum de la bobinatage. If relay functions correctly otherwise, the indicator light may be faulty (does not affect relay operation). |
| Relay remains energized after control voltage is removed | Contacts welded, residual magnetism, faulty coil. | Disconnect power immediately. Replace relay. Ensure load current is not exceeding ratings. |
9. Consells d'usuari
- When selecting a relay, always consider both the coil voltage (AC or DC) and the contact configuration (e.g., 2C) to match your application's needs.
- For applications requiring frequent switching, ensure the relay's electrical durability rating is sufficient to prevent premature failure.
- If using the relay with an inductive load, consider adding a snubber circuit or diode across the load to protect the relay contacts from arcing and extend its lifespan.
10. Garantia i Suport
Per obtenir informació sobre la garantia, assistència tècnica o consultes sobre el servei, poseu-vos en contacte amb el punt de compra original o directament amb el fabricant. Conserveu el rebut de compra com a comprovant de compra.