EARU THC15/THC30/AHC15A/AHC30

EARU Electric Weekly Programmable Digital Timer Switch Relay

Models: THC15, THC30, AHC15A, AHC30

La vostra guia d'instal·lació, funcionament i manteniment.

1. Introducció

The EARU Electric Weekly Programmable Digital Timer Switch Relay is a versatile device designed for precise time control of electrical appliances. It features advanced pre-setting capabilities for up to one week, with daily and weekly programs. With 18 ON/OFF settings, it allows for flexible scheduling and manual override. A built-in lithium battery provides power reserve, ensuring settings are retained even during power outages. The timer also includes automatic time error correction of ±30 seconds weekly.

EARU Electric Din Rail Timer Switch Relay with key features listed
Figura 1: Producte al llarg deview highlighting key features like 18 group settings, 30A relay, built-in lithium battery, intelligent periodic cycle, and automatic time correction.

2. Informació de seguretat

  • Always disconnect power before installing or performing maintenance on the device.
  • Installation should be performed by a qualified electrician to prevent electric shock or damage to the device.
  • Assegureu-vos que el volum del dispositiutage and current ratings match your application requirements.
  • Do not expose the device to moisture or extreme temperatures outside its specified operating range.

3. Especificacions

CaracterísticaEspecificació
Nom de marcaEARU
Números de modelTHC15, THC30, AHC15A, AHC30
TeoriaRelleu de temps
Font d'alimentacióAC
Voltage Classificació220 V CA
Voltage LímitAC180 ~ 240V
Vol. Operatiutage Opcions12V, 24V, 48V, 110V, 220V, 230V (AC/DC depending on model)
Corrent de càrrega30A
Funcionament ON / OFF18 ON & 18 OFF settings
Interval mínim1 minut
Consum d'energia7.5VA (max)
Reserva d'energia3 years (lithium battery)
Histèresi≤ 2 sec/day (at 25℃)
Auto Time Error Correction±30 sec, weekly
Service Life (Mechanical)107
Service Life (Electrical)105
Pesuns 150 g
Count Down Range1 sec - 99 min 59 sec
Rang de pols1 sec - 59 min 59 sec
Load Capacity (Resistive)30A 250V AC
Load Capacity (Lagging)25A/250V
Load Capacity (Lamp)4.5KW
Contacte de commutació1 interruptor de canvi
Temperatura ambient-10 a +40 ℃
Humitat ambiental35 ~ 85% HR
Dimensions (Alçada x Amplada x Llargada)87 mm (3.43 polzades) x 35 mm (1.38 polzades) x 65 mm (2.56 polzades)
Dimensions (Height from rail x Width from rail x Depth from rail)45 mm (1.77 polzades) x 48 mm (1.89 polzades) x 35 mm (1.38 polzades)
Product dimensions and technical parameters table
Figure 2: Detailed dimensions and technical specifications of the timer switch.

4. Contingut del paquet

  • 1 x EARU Electric Digital Timer Switch Relay
  • 1 x Manual d'instruccions (aquest document)

5. Configuració i instal·lació

5.1 Muntatge en carril DIN

The timer switch is designed for easy DIN-Rail mounting. Simply clip it onto a standard DIN rail in your electrical panel.

DIN-Rail mounting feature and other product details
Figure 3: The timer switch showing its DIN-Rail mounting capability.

5.2 Esquema de cablejat

Connect the timer switch according to the following diagrams. Ensure correct input voltage (N for Neutral, L for Live) and output connections (NC for Normally Closed, NO for Normally Open, and Common).

Labeled diagram of the timer's parts and wiring terminals
Figura 4: Detallada view of the timer's components and wiring terminals (N, L for input; 5, 4, 3 for output: NC, Common, NO).
Wiring diagram for a 1NO 220V AC configuration with a light bulb
Figura 5: Example wiring for a 1NO (Normally Open) 220V AC setup, connecting the timer to a light bulb.

5.3 Initial Power-up and Reset

Upon initial power-up or if the display is blank, the internal battery may need charging. The display should activate shortly after power is applied. To clear any previous settings and ensure proper operation, press the 'RESET' button using a thin, non-conductive object (e.g., a toothpick). The display will show '0:00' and 'AUTO'.

Video 1: Demonstration of resetting the timer and basic time setting.

6. Instruccions de funcionament

6.1 Controlsview

The timer features an LCD screen and several buttons for operation:

  • Indicador d'encesa: Shows when the timer is active.
  • Pantalla LCD: Displays time, day, and program status.
  • Timer button (P): Used to enter and navigate program settings.
  • Botó del rellotge: S'utilitza per configurar l'hora actual.
  • D+ (Day+): Adjusts the day of the week.
  • H+ (Hour+): Adjusts the hour.
  • M+ (Minute+): Adjusts the minute.
  • Botó de reset: Restableix tots els paràmetres per defecte.
  • Botó MANUAL: Cycles through ON, AUTO, and OFF modes.

6.2 Ajust de l'hora

Per configurar l'hora actual:

  1. First, ensure the clock display is consistent. If recalibration is needed, hold down the 'Clock' button.
  2. While holding 'Clock', press 'D+' to adjust the day of the week.
  3. While holding 'Clock', press 'H+' to adjust the hour.
  4. While holding 'Clock', press 'M+' to adjust the minute.
  5. Release all buttons once the accurate time is set.

6.3 Timer Setting (ON/OFF Programs)

The timer supports up to 18 ON/OFF program settings. Follow these steps for each program:

  1. Estableix l'hora d'encesa: Press the 'Timer' button (P) once. '1ON' will appear on the bottom left of the screen. Use 'D+', 'H+', and 'M+' buttons to set the desired ON time and day(s).
  2. Hora d'apagada: Press the 'Timer' button (P) again. '1OFF' will appear. Use 'D+', 'H+', and 'M+' buttons to set the desired OFF time and day(s). The shutdown date must correspond to the opening date.
  3. Set Additional Programs: Continue pressing the 'Timer' button (P) to cycle through '2ON', '2OFF', '3ON', '3OFF', up to '18ON', '18OFF'. Repeat steps 1 and 2 for each program.
  4. Clear Unused Programs: If you do not need all 18 programs, press the 'RESET' button while viewing an unused program slot to clear it. The display will show '--:--' instead of '00:00'.
Step-by-step instructions for time adjustment and timer settings
Figure 6: Visual guide for setting current time and programming ON/OFF schedules.

6.4 Manual Operation (ON/AUTO/OFF)

Press the 'MANUAL' button to cycle through the operating modes:

  • ACTIVITAT: The output is continuously ON, overriding programmed settings.
  • AUTOMÀTIC: The timer operates according to the programmed ON/OFF schedules.
  • DESACTIVAT: The output is continuously OFF, overriding programmed settings.

6.5 Intelligent Cycle System

The timer's intelligent cycle system allows for flexible scheduling, enabling the switch time to be cycled daily or weekly, with precise control over the timing.

Intelligent cycle system features: 18 groups, 30A, 3 years power reserve
Figura 7: Mésview of the intelligent cycle system, emphasizing 18 programmable groups, 30A high power relay, and 3 years of power failure memory.

7. Manteniment

  • Neteja: Netegeu el dispositiu amb un drap sec i suau. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Bateria: The internal lithium battery has a power reserve of approximately 3 years. It is not user-replaceable. If the display remains blank after prolonged power connection, the unit may need servicing or replacement.
  • Inspecció: Comproveu periòdicament les connexions del cablejat per comprovar si estan ben ajustades i si hi ha signes de desgast o danys.

8. Solució De Problemes

  • La pantalla està en blanc: Ensure the device is properly powered. The internal lithium battery may need charging; leave the device connected to power for a few hours. If still blank, the battery may be depleted or the unit faulty.
  • El temporitzador no s'encén/apaga segons la programació:
    • Comproveu si el temporitzador està en mode 'AUTO' (no en mode manual 'ON' o 'OFF').
    • Verify that the programmed times and days are correctly set.
    • Ensure any unused program slots are cleared (displaying '--:--').
    • Confirm the current time and day are accurately set on the timer.
  • Visualització de l'hora incorrecta: Recalibrate the time as described in Section 6.2. The device has an auto time error correction of ±30 seconds weekly, but significant drift may indicate an issue.
  • Device not responding to button presses: Try performing a 'RESET' using a thin object. If the issue persists, the device may be faulty.
  • Vol d'entrada/sortidatage Compatibilitat: Ensure that both the input and output voltages are compatible with the specific model of the timer switch you are using. For example, if you have a 220V AC model, ensure both input power and the connected load are rated for 220V AC.

9. Consells d'usuari

  • Voltage Verificació: Comproveu sempre el voltage rating of your specific timer model and ensure it matches your application's input and output requirements to prevent damage.
  • Program Clearing: When setting programs, make sure to clear any unused program slots by pressing the 'RESET' button on that specific program. This prevents unintended operations from default '00:00' settings.
  • Convex Buttons: The timer features convex buttons designed to prevent accidental operation. Use firm, deliberate presses when setting programs or adjusting time.
  • LCD Readability: The LCD display provides clear and intuitive data. Ensure good lighting conditions for optimal readability during programming.

10. Garantia i assistència

For warranty information or technical support, please refer to the product packaging or contact your retailer/manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents relacionats - THC15/THC30/AHC15A/AHC30

Preview EARU Automatic Transfer Switch (ATS) Operating Instruction and Technical Specifications
Comprehensive operating instructions and technical specifications for the EARU Automatic Transfer Switch (ATS) model EAATS-F-CG-80. Covers product overview, working conditions, model breakdown, detailed technical parameters, installation guidelines, maintenance procedures, and wiring diagrams.
Preview EARU EAL-2 Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EAL-2 series din rail circuit breaker, detailing its features, safety instructions, and product parameters for AC 2P 230V 4P 400V A Type RCBO RCCB MCB electronic residual current circuit breakers.
Preview EARU EAPDX-40/63 Series Adjustable VoltagManual d'usuari del protector de corrent i electròniques
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview EARU-X6/8 Metal LED Indicator Light Instruction Manual
User manual for EARU-X6/8 series Metal LED Indicator Lights, detailing safety instructions, warnings, and product description for reliable status indication in industrial and traffic applications.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.
Preview EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS) User Manual
User manual for the EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS). Learn how to install, connect, and operate the device using the EARU app for seamless switching between main and backup power sources.