Luxor CE-KFR26G/BP2N1Y-AE

Luxor Air Conditioning Control Board

Model: CE-KFR26G/BP2N1Y-AE

Introducció

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Luxor Air Conditioning Control Board, model CE-KFR26G/BP2N1Y-AE. This control board is a critical component designed to manage the functions of compatible air conditioning units. Please read this manual thoroughly before proceeding with any procedures.

Especificacions

AtributDetall
Número de modelCE-KFR26G/BP2N1Y-AE
TipusControl Board, Air Conditioner Parts
AplicacióCasa
CertificacióCE
OrigenXina continental
Substància química molt preocupantCap

Informació de seguretat

ADVERTIMENT: Electrical shock hazard. Always disconnect power to the air conditioning unit before attempting any installation, maintenance, or repair procedures. Failure to do so can result in serious injury or death.

  • Ensure all work is performed by qualified personnel.
  • Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi guants aïllants i ulleres de seguretat.
  • Verify that the replacement board matches the specifications of the original board.
  • Do not operate the air conditioning unit with damaged wiring or components.

Instal·lació

Installation of the control board should only be performed by a certified HVAC technician or a similarly qualified professional due to the electrical nature and complexity of air conditioning systems.

  1. Desconnecteu l'alimentació: Locate the circuit breaker for the air conditioning unit and switch it to the 'OFF' position. Verify power is off using a voltage provador.
  2. Tauler de control d'accés: Carefully open the air conditioning unit's access panel to expose the existing control board.
  3. Connexions de documents: Before disconnecting any wires, take clear photographs of all wiring connections to the old control board. Note the position and color of each wire. This is crucial for correct re-installation.
  4. Treure la placa antiga: Disconnect all wires and mounting screws securing the old control board. Carefully remove it from the unit.
  5. Instal·lar la placa nova: Position the new Luxor CE-KFR26G/BP2N1Y-AE control board in the same location as the old one. Secure it with the appropriate mounting screws.
  6. Reconnectar el cablejat: Using your documented photographs, carefully reconnect all wires to their corresponding terminals on the new control board. Ensure all connections are secure and properly seated.
  7. Tanca la unitat: Replace the access panel of the air conditioning unit, ensuring it is securely closed.
  8. Restaura l'alimentació i prova: Restore power to the air conditioning unit at the circuit breaker. Test the unit's functions to ensure proper operation.
Green Luxor Air Conditioning Control Board CE-KFR26G/BP2N1Y-AE
Figure 1: Green Luxor Air Conditioning Control Board (CE-KFR26G/BP2N1Y-AE), labeled 'Green Type A'.
White Luxor Air Conditioning Control Board
Figure 2: White Luxor Air Conditioning Control Board, an alternative version that may have different compatibility.

Funcionament

The Luxor Air Conditioning Control Board is an internal component that manages the various functions of your air conditioning unit. It does not have direct user-operable controls. Once correctly installed, the board operates automatically in conjunction with the unit's thermostat and other sensors to maintain desired climate conditions.

Manteniment

The control board itself requires minimal maintenance. However, regular inspection of the air conditioning unit and its components is recommended.

  • Mantenir sec: Ensure the control board area remains dry and free from moisture to prevent damage.
  • Neteja: Periodically inspect the board for dust or debris accumulation. If necessary, gently clean with a soft, dry brush or compressed air. Do not use liquids or harsh chemicals.
  • Inspeccionar connexions: During routine AC unit maintenance, visually inspect all wiring connections to the control board to ensure they remain secure and free from corrosion.

Resolució de problemes

If your air conditioning unit is not functioning correctly after installing the new control board, consider the following:

  • Sense energia: Double-check that the circuit breaker for the AC unit is in the 'ON' position and that all power connections to the board are secure.
  • Funcionalitat incorrecta: Verify that the installed control board is the correct model and type (e.g., green board vs. white board) for your specific air conditioning unit. Incompatibility can lead to improper operation.
  • Errors de cablejat: Review your wiring connections against the photographs taken during removal. Even a single misplaced wire can prevent proper operation.
  • Codis d'error: If the air conditioning unit displays error codes, consult your unit's specific user manual for the meaning of these codes and recommended solutions.
  • Assistència professional: If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for diagnosis and repair.

Consells per a l'usuari

  • Verify Board Type: Abans de la compraasing or installing, carefully compare your existing control board with the product images. Some models, like the CE-KFR26G/BP2N1Y-AE, may have different physical appearances (e.g., green vs. white boards) that are not interchangeable despite similar model numbers. Ensure you select the exact match for your unit.
  • Documenta-ho tot: Always take photos of wiring before disconnecting. This simple step can save significant time and prevent errors during re-installation.

Garantia i Suport

For any questions regarding the Luxor Air Conditioning Control Board or for technical support, please contact the seller, Trane Carrier York LG TCL Parts Store. Please have your product model number (CE-KFR26G/BP2N1Y-AE) and any relevant purchase information available when contacting support.

Documents relacionats - CE-KFR26G/BP2N1Y-AE

Preview Instruccions de muntatge i guia d'accessoris del carretó multiusos de plàstic Luxor
Instruccions de muntatge completes per als carrets multiusos de plàstic Luxor, incloent-hi els estàndard, els d'alta resistència, els paquets d'armari, el prestatge extraïble per al teclat i el muntatge elèctric. Troba llistes de peces, eines necessàries i guia pas a pas.
Preview Guia d'instal·lació de la torre de càrrega Luxor LUXPWR2
Instruccions pas a pas per muntar la torre de càrrega Luxor LUXPWR2, que inclou 8 ports de CA i 8 ports USB.
Preview LUXOR LX40BMS189T2 Característiques: Televisió
Löydä kaikki tarvitsemasi tiedot LUXOR LX40BMS189T2 -väritelevision käyttöön. Tämä käyttöohje sisältää asennus-, käyttö- ja vianmääritysohjeet.
Preview Guia d'instal·lació i manteniment de la banyera independent Luxor-Y644
Guia completa per a la instal·lació i el manteniment de la banyera independent Luxor-Y644, que inclou les característiques del producte, les dimensions, les instruccions de seguretat i els consells de cura.
Preview Instruccions de muntatge del separador d'habitacions modular LUXOR MW-7048-FCG
Guia de muntatge pas a pas per al sistema de paret divisòria modular LUXOR MW-7048-FCG, que detalla les peces i els procediments d'instal·lació.
Preview Presentació Luxor LED24HB/DVD
Complet d'empreses per a Luxor LED24HB/DVD LED TV amb un DVD-afspiller integrat. Dækker instal·lació, funktioner, betjening, medieafspilning, og fejlfinding.