1. Introducció
The BENETECH GT5105A is a high-accuracy and reliable digital earth resistance tester designed for measuring grounding resistance and ground voltage. It is controlled by an intelligent microcontroller chip, ensuring precise measurements for various power facilities wiring, electrical equipment, protection equipment, and other grounding devices. This manual provides detailed instructions for the safe and effective use of your GT5105A tester.

2. Informació de seguretat
Si us plau, llegiu i comprengui tots els avisos de seguretat i les instruccions d'ús abans d'utilitzar aquest instrument. Si no segueix aquestes instruccions, pot provocar descàrregues elèctriques, incendis o lesions greus.
- Assegureu-vos sempre que l'instrument estigui en bon estat de funcionament abans d'utilitzar-lo.
- Do not exceed the specified maximum input values for any measurement range.
- The device features double insulation and a reinforced insulation safety structure for enhanced user protection.
- Avoid using the instrument in wet environments or during electrical storms.
- Ensure all test leads are securely connected before performing any measurements.
- If the "---Ω" warning appears, check the contact of the C or E test lead.
- "OL" indicates an over-range condition; select a higher range if available or ensure the measurement is within the device's capabilities.
- Canvieu les piles immediatament quan aparegui l'indicador de bateria baixa per garantir lectures precises.
3. Contingut del paquet
Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:
- 1 x BENETECH GT5105A Digital Earth Resistance Tester
- 1 x 5 Meters Green Test Lead (with alligator clip)
- 1 x 10 Meters Yellow Test Lead (with alligator clip)
- 1 x 20 Meters Red Test Lead (with alligator clip)
- 2 x Auxiliary Ground Nails
- 1 x corretja de transport
- 1 x bossa de tela
- 1 x Instruction Manual (English)
4. Producte acabatview
The GT5105A features a clear digital display and intuitive controls for ease of use. Below is a diagram identifying the main components and their functions.

- Pantalla LCD: Large digital screen for displaying measurement values, units, and status indicators.
- Test Lead Connection Ports (E, P(S), C(H)): Terminals for connecting the test leads.
- Save Key: Used to save the current measurement data.
- Clau de prova: Inicia el procés de mesurament.
- Hold Key: Congela la lectura actual a la pantalla.
- Function Selection Switch: Rotary switch to select measurement modes (Earth Voltage, Ground Resistance ranges) and power the device on/off.
Les característiques addicionals inclouen:
- Clear Large Screen: For easy reading of measurements.
- Detecció de bateria: Indica l'estat de la bateria.
- Conversió d'unitat: Displays measurements in Volts (V) or Ohms (Ω).
- Overload Display ("OL"): Alerts when the measurement exceeds the selected range.
- Retenció de dades (HOLD): Allows freezing of displayed data.
- Emmagatzematge de dades: Capable of storing up to 20 sets of measurement data.
- Protective Cover Design: A robust cover protects the device when not in use.
- External Power Interface: Provides an option for external power supply.

5. Configuració
5.1 Instal·lació de la bateria
The GT5105A requires six 1.5V AA alkaline batteries (not included) for operation. To install or replace batteries:
- Ensure the Function Selection Switch is in the "OFF" position.
- Localitzeu el compartiment de la bateria a la part posterior del dispositiu.
- Obriu la tapa del compartiment de la bateria.
- Insert six 1.5V AA alkaline batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Tanqueu bé la tapa del compartiment de la bateria.

5.2 Connexió dels cables de prova
Connect the provided test leads to the appropriate ports (E, P(S), C(H)) on the tester. The leads are color-coded for easy identification:
- Green Test Lead (5 meters)
- Yellow Test Lead (10 meters)
- Red Test Lead (20 meters)
The auxiliary ground nails are used in conjunction with the test leads for earth resistance measurements.
6. Instruccions de funcionament
6.1 Engegada/apagada
Rotate the Function Selection Switch to any desired measurement range (e.g., 20Ω, 200V) to power on the device. To power off, rotate the switch to the "OFF" position.
6.2 Ground Voltage Mesura
To measure ground voltage:
- Rotate the Function Selection Switch to the "EARTH VOLTAGE" position.
- Connect the test leads to the appropriate points for voltage mesura.
- The measured ground voltage es mostrarà a la pantalla LCD.
6.3 Ground Resistance Measurement (Three-Wire Method)
For precise three-wire ground resistance measurement:
- Connect the test leads and auxiliary ground nails according to standard three-wire earth resistance testing procedures.
- Rotate the Function Selection Switch to the desired ground resistance range (20Ω, 200Ω, or 2000Ω).
- Press the "TEST" key to initiate the measurement.
- The ground resistance value will be displayed on the LCD.
- If the reading shows "---Ω", check the connections of the C and E test leads for poor contact.
- If "OL" is displayed, the resistance is out of range; select a higher range or verify the circuit.

6.4 Ground Resistance Measurement (Two-Wire Method)
For simple two-wire ground resistance measurement:
- Connect the test leads for two-wire measurement.
- Rotate the Function Selection Switch to the "2000Ω (2WIRES)" position.
- Press the "TEST" key to initiate the measurement.
- The ground resistance value will be displayed on the LCD.
6.5 Funció de retenció de dades
Per congelar la lectura actual a la pantalla:
- During a measurement, press the "HOLD" key. The "HOLD" symbol will appear on the LCD.
- To release the hold and resume live readings, press the "HOLD" key again.
6.6 Emmagatzematge i reemmagatzematge de dadesview
The GT5105A can store up to 20 sets of measurement data.
- After a measurement, press the "SAVE" key to store the value. If the memory is full, "FULL" will be indicated.
- Per tornarview stored data, refer to the specific instructions in the full manual (not provided here).
- Stored data can also be deleted as needed.

7. Manteniment
7.1 Neteja
Wipe the instrument with a soft, dry cloth. Do not use abrasives or solvents. Ensure no moisture enters the device.
7.2 Substitució de la bateria
When the battery detection function indicates low power, replace all six AA batteries as described in Section 5.1.
7.3 Emmagatzematge
When not in use for extended periods, store the GT5105A in a dry environment with temperatures between -20℃ and 60℃ and relative humidity below 70% (non-condensing). Remove batteries if storing for a long time to prevent leakage.

8. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| "---Ω" warning on LCD | Poor contact of C or E test lead. | Check and re-secure the connections of the C and E test leads. Ensure good contact with the ground. |
| "OL" displayed on LCD | Measurement value exceeds the selected range. | Select a higher measurement range using the Function Selection Switch. Verify the circuit being tested is within the device's capabilities. |
| El dispositiu no s'encén | Piles gastades o instal·lades incorrectament. | Check battery installation and polarity. Replace with fresh batteries if necessary. |
| Lectures inexactes | Low battery, poor test lead connections, or environmental factors. | Ensure batteries are fresh. Check all test lead connections. Perform measurements within specified working environment conditions. |

9. Especificacions
Detailed technical specifications for the BENETECH GT5105A Digital Earth Resistance Tester:
| Paràmetre | Detall |
|---|---|
| Terra voltagmesura | Average response |
| Temperatura de treball | 5 ~ 40 ℃ |
| Relative humidity (working) | ≤80%RH (no fog) |
| Altituds | ≤2000 metres |
| Temperatura d'emmagatzematge | -20 ~ 60 ℃ |
| Humitat relativa (emmagatzematge) | ≤70%RH (no fog) |
| Font d'alimentació | 9V power supply [1.5V AA alkaline battery *6] (NOT included) |
| Ground resistance overload | 200V AC (10 seconds) |
| Terra voltage sobrecàrrega | 400V AC (30 seconds) |
| Mida de l'article | 176 * 110 * 77 mm / 6.93 * 4.33 * 3.03 polzades |
| Resistència d'aïllament | Between measurement circuit and case is not less than 20MΩ |
Ground Resistance Measurement Ranges
| Interval | Precisió | Resolució |
|---|---|---|
| 20Ω | ±(2%+10) | 0.01Ω |
| 200Ω | ±(2%+3) | 0.1Ω |
| 2000Ω (two wires) | ±(2%+3) | 1Ω |
| 2000Ω | ±(2%+5) | 1Ω |
Terra Voltage Interval de mesura
| Interval | Precisió | Resolució |
|---|---|---|
| 200 V | ±(2%+5) | 0.1 V |

10. Consells d'usuari
No hi ha consells específics per a l'usuari de reviews or Q&A were provided for this product. However, general best practices for using earth resistance testers include:
- Always ensure good contact between the auxiliary ground nails and the earth for accurate readings.
- When performing measurements, try to keep the test leads as straight as possible to minimize interference.
- Regularly check the condition of your test leads and alligator clips for wear and tear.
- For critical measurements, perform multiple readings and average the results to ensure consistency.
11. Garantia i Suport
This product comes with a 1-year guarantee from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For technical support, troubleshooting assistance, or warranty claims, please contact your original point of purchase or the manufacturer's customer service. Please have your product model number (GT5105A) and purchase details ready when contacting support.