The BENETECH GT5105A is a high-accuracy and reliable digital earth resistance tester designed for measuring grounding resistance and ground voltage. It is controlled by an intelligent microcontroller chip, ensuring precise measurements for various power facilities wiring, electrical equipment, protection equipment, and other grounding devices. This manual provides detailed instructions for the safe and effective use of your GT5105A tester.

BENETECH GT5105A Digital Earth Resistance Tester with included accessories
Figure 1: BENETECH GT5105A Digital Earth Resistance Tester and its accessories.

2. Informació de seguretat

Si us plau, llegiu i comprengui tots els avisos de seguretat i les instruccions d'ús abans d'utilitzar aquest instrument. Si no segueix aquestes instruccions, pot provocar descàrregues elèctriques, incendis o lesions greus.

  • Assegureu-vos sempre que l'instrument estigui en bon estat de funcionament abans d'utilitzar-lo.
  • Do not exceed the specified maximum input values for any measurement range.
  • The device features double insulation and a reinforced insulation safety structure for enhanced user protection.
  • Avoid using the instrument in wet environments or during electrical storms.
  • Ensure all test leads are securely connected before performing any measurements.
  • If the "---Ω" warning appears, check the contact of the C or E test lead.
  • "OL" indicates an over-range condition; select a higher range if available or ensure the measurement is within the device's capabilities.
  • Canvieu les piles immediatament quan aparegui l'indicador de bateria baixa per garantir lectures precises.

3. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:

  • 1 x BENETECH GT5105A Digital Earth Resistance Tester
  • 1 x 5 Meters Green Test Lead (with alligator clip)
  • 1 x 10 Meters Yellow Test Lead (with alligator clip)
  • 1 x 20 Meters Red Test Lead (with alligator clip)
  • 2 x Auxiliary Ground Nails
  • 1 x corretja de transport
  • 1 x bossa de tela
  • 1 x Instruction Manual (English)

4. Producte acabatview

The GT5105A features a clear digital display and intuitive controls for ease of use. Below is a diagram identifying the main components and their functions.

Labeled diagram of BENETECH GT5105A showing LCD, test lead ports, and control buttons
Figure 2: Main components of the GT5105A Digital Earth Resistance Tester.
  1. Pantalla LCD: Large digital screen for displaying measurement values, units, and status indicators.
  2. Test Lead Connection Ports (E, P(S), C(H)): Terminals for connecting the test leads.
  3. Save Key: Used to save the current measurement data.
  4. Clau de prova: Inicia el procés de mesurament.
  5. Hold Key: Congela la lectura actual a la pantalla.
  6. Function Selection Switch: Rotary switch to select measurement modes (Earth Voltage, Ground Resistance ranges) and power the device on/off.

Les característiques addicionals inclouen:

  • Clear Large Screen: For easy reading of measurements.
  • Detecció de bateria: Indica l'estat de la bateria.
  • Conversió d'unitat: Displays measurements in Volts (V) or Ohms (Ω).
  • Overload Display ("OL"): Alerts when the measurement exceeds the selected range.
  • Retenció de dades (HOLD): Allows freezing of displayed data.
  • Emmagatzematge de dades: Capable of storing up to 20 sets of measurement data.
  • Protective Cover Design: A robust cover protects the device when not in use.
  • External Power Interface: Provides an option for external power supply.
Close-up of probe socket, protective cover, battery compartment, and external power interface
Figura 3: Detallada views of the GT5105A's features.

5. Configuració

5.1 Instal·lació de la bateria

The GT5105A requires six 1.5V AA alkaline batteries (not included) for operation. To install or replace batteries:

  1. Ensure the Function Selection Switch is in the "OFF" position.
  2. Localitzeu el compartiment de la bateria a la part posterior del dispositiu.
  3. Obriu la tapa del compartiment de la bateria.
  4. Insert six 1.5V AA alkaline batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Tanqueu bé la tapa del compartiment de la bateria.
Detallada view of the battery compartment showing battery placement
Figure 4: Battery compartment for six 1.5V AA alkaline batteries.

5.2 Connexió dels cables de prova

Connect the provided test leads to the appropriate ports (E, P(S), C(H)) on the tester. The leads are color-coded for easy identification:

  • Green Test Lead (5 meters)
  • Yellow Test Lead (10 meters)
  • Red Test Lead (20 meters)

The auxiliary ground nails are used in conjunction with the test leads for earth resistance measurements.

6. Instruccions de funcionament

6.1 Engegada/apagada

Rotate the Function Selection Switch to any desired measurement range (e.g., 20Ω, 200V) to power on the device. To power off, rotate the switch to the "OFF" position.

6.2 Ground Voltage Mesura

To measure ground voltage:

  1. Rotate the Function Selection Switch to the "EARTH VOLTAGE" position.
  2. Connect the test leads to the appropriate points for voltage mesura.
  3. The measured ground voltage es mostrarà a la pantalla LCD.

6.3 Ground Resistance Measurement (Three-Wire Method)

For precise three-wire ground resistance measurement:

  1. Connect the test leads and auxiliary ground nails according to standard three-wire earth resistance testing procedures.
  2. Rotate the Function Selection Switch to the desired ground resistance range (20Ω, 200Ω, or 2000Ω).
  3. Press the "TEST" key to initiate the measurement.
  4. The ground resistance value will be displayed on the LCD.
  5. If the reading shows "---Ω", check the connections of the C and E test leads for poor contact.
  6. If "OL" is displayed, the resistance is out of range; select a higher range or verify the circuit.
GT5105A showing multiple gear selection for resistance and voltage mesures
Figure 5: Multiple gear selection for resistance and voltage mesures.

6.4 Ground Resistance Measurement (Two-Wire Method)

For simple two-wire ground resistance measurement:

  1. Connect the test leads for two-wire measurement.
  2. Rotate the Function Selection Switch to the "2000Ω (2WIRES)" position.
  3. Press the "TEST" key to initiate the measurement.
  4. The ground resistance value will be displayed on the LCD.

6.5 Funció de retenció de dades

Per congelar la lectura actual a la pantalla:

  1. During a measurement, press the "HOLD" key. The "HOLD" symbol will appear on the LCD.
  2. To release the hold and resume live readings, press the "HOLD" key again.

6.6 Emmagatzematge i reemmagatzematge de dadesview

The GT5105A can store up to 20 sets of measurement data.

  1. After a measurement, press the "SAVE" key to store the value. If the memory is full, "FULL" will be indicated.
  2. Per tornarview stored data, refer to the specific instructions in the full manual (not provided here).
  3. Stored data can also be deleted as needed.
GT5105A demonstrating data storage after measurement, with 'FULL' indicator
Figure 6: Saving measurement data and "FULL" indicator for data storage.

7. Manteniment

7.1 Neteja

Wipe the instrument with a soft, dry cloth. Do not use abrasives or solvents. Ensure no moisture enters the device.

7.2 Substitució de la bateria

When the battery detection function indicates low power, replace all six AA batteries as described in Section 5.1.

7.3 Emmagatzematge

When not in use for extended periods, store the GT5105A in a dry environment with temperatures between -20℃ and 60℃ and relative humidity below 70% (non-condensing). Remove batteries if storing for a long time to prevent leakage.

GT5105A with its protective cover open, emphasizing double insulation for safety
Figure 7: The protective cover design enhances safety and durability.

8. Solució De Problemes

ProblemaCausa possibleSolució
"---Ω" warning on LCDPoor contact of C or E test lead.Check and re-secure the connections of the C and E test leads. Ensure good contact with the ground.
"OL" displayed on LCDMeasurement value exceeds the selected range.Select a higher measurement range using the Function Selection Switch. Verify the circuit being tested is within the device's capabilities.
El dispositiu no s'encénPiles gastades o instal·lades incorrectament.Check battery installation and polarity. Replace with fresh batteries if necessary.
Lectures inexactesLow battery, poor test lead connections, or environmental factors.Ensure batteries are fresh. Check all test lead connections. Perform measurements within specified working environment conditions.
GT5105A displaying 'OL' for over-range warning, with a red warning light
Figure 8: Over-range warning ("OL") on the display.

9. Especificacions

Detailed technical specifications for the BENETECH GT5105A Digital Earth Resistance Tester:

ParàmetreDetall
Terra voltagmesuraAverage response
Temperatura de treball5 ~ 40 ℃
Relative humidity (working)≤80%RH (no fog)
Altituds≤2000 metres
Temperatura d'emmagatzematge-20 ~ 60 ℃
Humitat relativa (emmagatzematge)≤70%RH (no fog)
Font d'alimentació9V power supply [1.5V AA alkaline battery *6] (NOT included)
Ground resistance overload200V AC (10 seconds)
Terra voltage sobrecàrrega400V AC (30 seconds)
Mida de l'article176 * 110 * 77 mm / 6.93 * 4.33 * 3.03 polzades
Resistència d'aïllamentBetween measurement circuit and case is not less than 20MΩ

Ground Resistance Measurement Ranges

IntervalPrecisióResolució
20Ω±(2%+10)0.01Ω
200Ω±(2%+3)0.1Ω
2000Ω (two wires)±(2%+3)
2000Ω±(2%+5)

Terra Voltage Interval de mesura

IntervalPrecisióResolució
200 V±(2%+5)0.1 V
Table of technical specifications for the GT5105A
Figure 9: Summary of technical specifications.

10. Consells d'usuari

No hi ha consells específics per a l'usuari de reviews or Q&A were provided for this product. However, general best practices for using earth resistance testers include:

  • Always ensure good contact between the auxiliary ground nails and the earth for accurate readings.
  • When performing measurements, try to keep the test leads as straight as possible to minimize interference.
  • Regularly check the condition of your test leads and alligator clips for wear and tear.
  • For critical measurements, perform multiple readings and average the results to ensure consistency.

11. Garantia i Suport

This product comes with a 1-year guarantee from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical support, troubleshooting assistance, or warranty claims, please contact your original point of purchase or the manufacturer's customer service. Please have your product model number (GT5105A) and purchase details ready when contacting support.

Documents relacionats - GT5105A

Preview Manual d'instruccions del provador d'aïllament/continuïtat BENETECH GT5307B
Manual d'instruccions complet per al provador d'aïllament/continuïtat BENETECH GT5307B, que detalla les seves característiques, funcionament, especificacions, avisos de seguretat, manteniment i informació sobre garantia.
Preview Manual d'instruccions del luxòmetre de tipus dividit Benetech GM1030C
Manual d'instruccions del luxòmetre de tipus dividit Benetech GM1030C, que cobreix la introducció del producte, les característiques, el funcionament, el rendiment i la connectivitat amb PC/aplicació.
Preview Manual d'instruccions del monitor de micro potència BENETECH GM86
Instruction manual for the BENETECH GM86 Micro Power Monitor, detailing its features, safety instructions, operating procedures, application cases, maintenance, and technical specifications for measuring voltage, corrent, potència i consum d'energia.
Preview Manual d'instruccions de l'anemòmetre digital Benetech GT8907
Manual d'instruccions de l'anemòmetre digital Benetech GT8907, que cobreix la configuració, el funcionament, les especificacions, la connexió a l'ordinador i la resolució de problemes.
Preview Manual d'instruccions de l'anemòmetre digital BENETECH GT8913
Manual d'instruccions de l'anemòmetre digital BENETECH GT8913, que cobreix la configuració, el funcionament, les especificacions, la resolució de problemes i el manteniment. Ofereix una guia detallada sobre l'ús del dispositiu per mesurar la velocitat del vent, la temperatura, la humitat i el volum d'aire.
Preview Manual d'instruccions del mesurador d'humitat i temperatura BENETECH GM1371
Manual d'instruccions del mesurador d'humitat i temperatura BENETECH GM1371, que detalla les seves característiques, funcionament, especificacions tècniques i anuncis importants.