1. Introducció
The EGBO CD60L (XH-M609) is a versatile dual-mode battery charging and discharging control protector module. It features a liquid crystal display for real-time voltage i percentatgetage monitoring, and is compatible with various battery types, including lithium batteries, operating within a DC 6-60V range. This module is designed to manage battery charging and discharging processes, offering undervoltage i overvoltage protection to extend battery life in applications such as solar power systems, battery management, and general electronic projects.

Figure 1: EGBO CD60L (XH-M609) Module Overview
2. Especificacions
| Característica | Especificació |
|---|---|
| Número de model | XH-M609 (CD60L) |
| Nom de marca | EGBO |
| Tipus | Voltage Regulator / Battery Charge/Discharge Controller |
| Subministrament Voltage | DC 6V - 60V (Compatible with 12V, 24V, 48V battery systems) |
| Temperatura de funcionament | -40 °C a +85 °C |
| paquet | DIY KIT |
| Dimensions (L x A) | 4.6 cm x 4.5 cm |
| Pes | 24.56 g |
| Mostra | Liquid Crystal Display (LCD) for Voltage i Percentage |
| Relleu | SRA-05VDC-CL (Rated 20A 14VDC, 20A 125VAC) |

Figure 2: Module Dimensions and Weight
3. Configuració i cablejat
The CD60L module functions as a switching relay to control charging or discharging based on user-defined voltage parameters. It is important to note that this module does not regulate voltage directly; it only connects or disconnects the power path.
3.1. Charging Mode (IN) Wiring
In charging mode, the module controls the power flow from a charger to the battery. When the battery voltage drops below the set lower limit (dn), the relay closes, allowing the charger to charge the battery. When the battery voltage reaches or exceeds the set upper limit (UP), the relay opens, stopping the charging process. The display will show "IN" and blink during active charging.

Figure 3: Charging Mode (IN) Wiring Diagram
- Connect the DC 6-60V power source (charger input) to the "VIN+ VIN-" terminals.
- Connect the battery to be charged to the "OUT+ OUT-" terminals.
- Ensure correct polarity (+ to + and - to -) for all connections.
3.2. Discharge Mode (OUT) Wiring
In discharge mode, the module controls the power flow from the battery to a connected load. When the battery voltage is greater than or equal to the set upper limit (UP), the relay closes, allowing the load to draw power. When the battery voltage drops below the set lower limit (dn), the relay opens, disconnecting the load to protect the battery from undervoltage. The display will show "OUT" and blink during active discharging.

Figure 4: Discharge Mode (OUT) Wiring Diagram
- Connect the battery to the "VIN+ VIN-" terminals.
- Connect the load to the "OUT+ OUT-" terminals.
- Ensure correct polarity (+ to + and - to -) for all connections.
Nota important:
This product is a simple voltage controller that operates via a relay to turn the output on and off. It serves only as a switching mechanism and cannot change or regulate the voltage nivell.
4. Instruccions de funcionament
4.1. Funcions clau

Figure 5: Control Buttons and Display
- Botó amunt:
- Short press: Toggles the display between voltage per centtage (%) and elapsed time (h).
- Long press (approx. 5 seconds): Switches the operating mode between Charging Mode (IN) and Discharge Mode (OUT).
- Botó ABAIX:
- Short press: Toggles the relay enable function (emergency stop). This action also turns off the LCD display.
- Long press: Sets the status of the LCD backlight (L-P).
OFF: Backlight remains constantly ON.ON: Backlight automatically extinguishes after 5-10 minutes of inactivity; any key press will reactivate it.
- Botó SET:
- Short press: Displays the parameters currently set.
- Long press: Enters the parameter setting interface.
4.2. Configuració dels paràmetres
Follow these steps to configure the module's operating parameters:
- Manteniu premuda la SET key to enter the parameter setting screen.
- On the parameter setting screen, press the SET key repeatedly to cycle through and select different parameters.
- Once a parameter is selected, use the Amunt/Avall keys to adjust its value. You can press briefly for incremental changes or hold down for faster adjustment.
- To set other parameters, repeat steps 2 and 3.
- After all desired parameters are adjusted, press and hold the SET key again to exit the setting interface and save your changes.
4.2.1. Parameters in Charging Mode (IN)

Figure 6: Charging Mode Parameter Display
- UP (Upper Voltage Limit): El voltage threshold at which the charging process will stop.
- dn (Lower Voltage Limit): El voltage threshold at which the charging process will start.
- OP (Charge Time Control): Set a non-zero value (in hours) to enable time-based charging. If set to 0, time control is disabled, and charging is solely voltagcontrolat electrònicament.
- dOP (Delay Turn-on Time): Specifies the interval (0-999 seconds) between the completion of a charge/discharge cycle and the next activation of the relay.
4.2.2. Parameters in Discharge Mode (OUT)

Figure 7: Discharge Mode Parameter Display
- UP (Upper Voltage Limit): El voltage threshold at which the discharging process will start.
- dn (Lower Voltage Limit): El voltage threshold at which the discharging process will stop (undervoltage protecció).
- OP (Discharge Time Control): Set a non-zero value (in hours) to enable time-based discharging. If set to 0, time control is disabled, and discharging is solely voltagcontrolat electrònicament.
- dOP (Delay Turn-on Time): Specifies the interval (0-999 seconds) between the completion of a charge/discharge cycle and the next activation of the relay.
- FOP (Forced Start Time): After the relay's ON condition is met, the relay is forced ON for a set duration (0-10 seconds). This function is primarily for discharge mode to prevent premature relay disconnection due to instantaneous voltage drops when a test load is initially applied.
4.3. Time Control Function (OP)
Quan el OP parameter is set to a non-zero value, the module initiates a timer when the relay activates for either charging or discharging. Upon completion of the set time, the relay automatically disconnects to conclude the process. If the timer finishes but the voltage condition (e.g., voltage dn in charging mode, or voltage > UP in discharge mode) is not met, the time control function will automatically deactivate, and "H:ER" will blink on the display, indicating an improper time parameter setting. Press any key to clear the "H:ER" message.
If time control is disabled (OP=0), the module will record the cumulative time the relay was active. This recorded charging/discharging time will blink on the display when you access the time display interface. It will reset upon exiting the time display or at the start of the next charge/discharge cycle.
4.4. Voltage Percenttage Càlcul
El vol mostrattage per centtage is calculated using the formula: Battery Voltage / (Upper Voltage - Lower Voltage).
5. Solució De Problemes
- "ERR" Display: If the system displays "ERR" after setting parameters and exiting, it indicates that the lower voltage limit (
dn) has been set to be greater than or equal to the upper voltage limit (UP). This is an invalid configuration. Please review and correct your voltage settings to ensureUPis always greater thandn. - "H:ER" Blinking: This message indicates an issue with the time parameter (
OP) setting. The time control function has automatically turned off because the voltage condition was not met upon completion of the set time. Adjust yourOPparameter or ensure your voltage limits are appropriate for the timed operation. Press any key to clear the "H:ER" message. - Relay Not Activating/Deactivating as Expected:
- Cablejat: Double-check all wiring connections for correct polarity and secure contact. Loose connections can cause intermittent operation.
- Entrada Voltage: Comproveu que l'entrada voltage to the module is within the specified DC 6-60V operating range.
- Configuració dels paràmetres: Ensure the current battery voltage is within the set
UP/dnparameters for the selected mode (IN/OUT) to trigger the relay. - Parada d'emergència: Check if the emergency stop function (short press DOWN button) has been accidentally activated, which disables the relay.
- La pantalla no funciona:
- Font d'alimentació: Confirm that the module is receiving power.
- Retroil·luminació LCD: If the LCD backlight is set to "ON" (L-P parameter), it might have automatically turned off due to inactivity. Press any key to wake it up.
6. Manteniment
To ensure optimal performance and longevity of your CD60L module, follow these maintenance guidelines:
- Neteja: Keep the module clean and free from dust, dirt, and debris. Use a soft, dry cloth for cleaning.
- Protecció contra la humitat: Eviteu exposar el mòdul a la humitat o a líquids, ja que això pot causar curtcircuits i danys.
- Control de temperatura: Do not expose the module to extreme temperatures outside its specified operating range (-40°C to +85°C).
- Connexions segures: Regularly check that all wiring connections are secure and free from corrosion to prevent intermittent operation or potential damage.
- Gestió de càrrega: No excedeixi el vol especificattage (DC 6-60V) or the current ratings of the onboard relay (20A) to prevent overheating and damage to the module or connected components.
7. Consells d'usuari
- Prova inicial: Before integrating the module into a critical system, it is highly recommended to perform initial tests with a small battery and a controlled load/charger. This allows you to familiarize yourself with the settings and observe its behavior safely.
- Voltage Precisió: For applications requiring high precision, consider verifying the module's voltage readings against a calibrated multimeter. While the module provides a clear display, external verification can ensure exact control.
- Desar la configuració: Always remember to long-press the SET button after making any parameter adjustments. Unsaved changes will be lost if power is removed or the module is reset.
- Understanding Relay Operation: Keep in mind that the module's relay acts as a simple on/off switch. It does not actively regulate voltage or current. Ensure that your connected charger or load is appropriate for the battery type and capacity you are using.
- La seguretat primer: When working with electrical components and batteries, always observe proper safety precautions, including wearing appropriate personal protective equipment and ensuring circuits are de-energized before making connections.
8. Garantia i Suport
For any technical assistance, troubleshooting, or warranty-related inquiries regarding your EGBO CD60L (XH-M609) module, please contact your original retailer or the manufacturer's customer support channels. Please retain your proof of purchase for any potential warranty claims. Specific warranty terms and conditions may vary depending on the region and the seller from whom the product was purchased.