weytoll TC-8200 / TC-8100

Weytoll TC-8200 / TC-8100 Dust Particle Counter User Manual

PM2.5 PM10 Detector, Dust Concentration Tester, Temperature & Humidity Meter for Clean Room

Models: TC-8200 (Grey & Red), TC-8100 (Grey & Yellow)

1. Introducció

The Weytoll TC-8200 and TC-8100 are advanced dust particle counters designed for monitoring air quality, temperature, humidity, and AQI (Air Quality Index) grade. Utilizing a scattering principle, these devices provide accurate and reliable measurements for various applications, including clean room inspection, industrial production, and particle pollution source detection. Both models feature a 3.2-inch TFT full-color display, data recording capabilities, and a user-friendly interface.

TC-8100 and TC-8200 Dust Particle Counters with accessories, highlighting key features like PM2.5, PM10, Humidity, Temperature, and Color Backlight.
Figure 1: Weytoll TC-8100 and TC-8200 Dust Particle Counters with included accessories.

2. Package Contents & Setup

2.1 Contingut del paquet

En obrir el paquet, assegureu-vos que hi hagi tots els elements presents:

  • 1 x Dust Particle Counter (TC-8100 or TC-8200)
  • 1 x cable USB
  • 1 x trípode
  • 1 manual d'usuari (anglès)
Contents of the TC-8100 package, including the device, tripod, user manual, USB cable, and carrying case.
Figure 2: Typical package contents for the TC-8100 model.

2.2 Font d'alimentació

The device can be powered by its built-in rechargeable lithium battery or via a USB cable. The 2200mAh lithium battery provides approximately 9 hours of working time and can be charged using the provided USB cable. The battery cover is designed for easy removal and installation, facilitating battery replacement when necessary.

Diagram illustrating the dual power supply options for the device: USB Charging Port and a Removable 2200mAh Lithium Battery.
Figure 3: Dual power supply options: USB charging and removable lithium battery.

2.3 Attaching the Tripod

For stable measurements, attach the included tripod to the device. The tripod screws into the designated port at the bottom of the unit.

Video 1: Demonstration of unboxing, tripod attachment, and basic operation of the TC-8200.
The TC-8200 Dust Particle Counter mounted on its included tripod, showing its display.
Figure 4: TC-8200 mounted on its tripod for stable measurements.

3. Instruccions de funcionament

3.1 Dispositiu acabatview

Familiaritzeu-vos amb els components i els controls del dispositiu:

Labeled diagram of the TC-8200 Dust Particle Counter, indicating components such as Air Intake, Temperature & Humidity Sensor, 3.2" TFT Screen, control buttons (Confirm, Curve Graph, Mode Switch, Power on/off, Alarm Buzzer, Alarm Value Set, °C/°F), Battery Cover, Tripod Support, and Air Outlet.
Figure 5: Labeled diagram of the TC-8200 Dust Particle Counter.
  • Entrada/sortida d'aire: Points for air sampllengüeta
  • Sensor de temperatura i humitat: Measures ambient temperature and humidity.
  • 3.2" TFT Screen: Displays all measurement data and settings.
  • Botons de control: Include Power on/off, Mode Switch, Confirm (ENTER), Curve Graph, Alarm Value Set, and °C/°F switch.
  • Tapa de la bateria: Located at the back for battery access.
  • Tripod Support: Threaded hole for tripod attachment.

3.2 Encès/Apagat

Manteniu premut el botó d'engegada (Power on/off button icon) to turn the device on or off. The device will undergo a boot stabilization period of approximately 10 seconds before displaying readings.

3.3 Lectura de mesures

The 3.2-inch TFT color screen displays real-time data for particulate matter (PM2.5, PM10, and various particle sizes), temperature, and humidity. The display also shows the AQI Grade.

Close-up of the TC-8200 display showing real-time air quality data, including PM2.5, PM10, temperature, and humidity readings.
Figure 6: Real-time air quality data display on TC-8200.
  • TC-8100: Detects 0.3μm, 2.5μm particle sizes, PM2.5, PM10 concentration, AQI Grade, temperature, and humidity.
  • TC-8200: Detects 0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10μm particle sizes, PM2.5, PM10 concentration, AQI Grade, temperature, and humidity. It can also assess cleanliness against ISO 14644-1 ISO5 to ISO9 levels.

3.4 Data Record & Curve Graph

The device can store up to 999 groups of data records. Press the 'Curve Graph' button to view historical data curves, allowing for convenient analysis of trends over time.

The TC-8200 display showing a data record and curve graph, illustrating its data logging capabilities.
Figure 7: Data record and curve graph display on TC-8200.

3.5 PM2.5 Alarm Function

The device includes a PM2.5 alarm function. You can easily turn the alarm buzzer on or off and set a custom alarm value using the 'Alarm Value Set' button.

Image showing the TC-8200 display with a PM2.5 alarm icon, indicating the device's alarm function.
Figure 8: PM2.5 alarm indicator on the display.

3.6 Menú de configuració

Access the settings menu to configure various parameters:

  • OFF-Backlight: Ajusteu la configuració de la llum de fons.
  • Interval de registre: Set the interval for data recording.
  • Brillantor: Ajusteu la brillantor de la pantalla.
  • Esborra les dades: Clear recorded data.
  • Time&Date: Estableix l'hora i la data actuals.
  • Apagat automàtic: Configure automatic power-off to save battery.
  • Idioma: Seleccioneu l'idioma de visualització (per exemple, anglès).
  • Restablir: Restableix el dispositiu a la configuració de fàbrica.

3.7 Exporting Data

The device supports exporting data, including PDF reports, by connecting to a computer via USB. Navigate to the data export option in the settings menu and follow the on-screen prompts.

Video 2: Demonstration of exporting data to PDF via USB connection.

4. Manteniment

4.1 Neteja

To maintain optimal performance, keep the device clean. Use a soft, dry cloth to wipe the exterior. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the air intake and outlet ports are free from dust and obstructions.

4.2 Substitució de la bateria

The device features a removable lithium battery. If the battery's performance degrades over time, it can be replaced. Carefully open the battery cover located on the back of the device, remove the old battery, and insert a new compatible 3.7V 2200mAh lithium battery. Ensure correct polarity before closing the cover.

5. Solució De Problemes

Si teniu problemes amb el dispositiu, tingueu en compte els passos habituals següents per resoldre problemes:

  • El dispositiu no s'encén: Ensure the battery is charged or connected to a USB power source. Check if the battery is correctly installed.
  • Lectures inexactes: Ensure the air intake/outlet is clear of obstructions. Allow the device to stabilize for at least 10 seconds after powering on. Perform a factory reset if necessary.
  • La pantalla no respon: Try restarting the device. If the issue persists, ensure the battery is adequately charged.
  • Data export issues: Verify the USB cable connection to both the device and the computer. Ensure the correct export option is selected on the device.

Per a problemes persistents, consulteu la secció detallada de resolució de problemes del manual d'usuari complet o poseu-vos en contacte amb el servei d'atenció al client.

6. Especificacions

Característica Especificació
Nom de marca weytoll
Número de model TC-8100 / TC-8200 Dust Particle Counter
Color TC-8100: Grey & Yellow; TC-8200: Grey & Red
Material ABS
Mostra 3.2-inch TFT Full-Color Screen
Tipus de gas PM2.5, PM10
Concentration Resolution 1μg/m³
Caudal 1 litre/min (2.83L=1L*2.83)
Temps de resposta Aprox. 1 segons
Boot Stabilization Time Aprox. 10 segons
Interval de mesura de temperatura -10 ~ 60 ℃
Precisió de la temperatura ± 2 ℃
Resolució de temperatura 0.01℃
Interval de mesura de la humitat 0 ~ 100% HR
Precisió de la humitat ±3% HR
Resolució d’humitat 0.01% HR
Bateria Bateria de liti de 3.7 V 2200 mAh integrada
Bateria inclosa No (refers to additional/spare battery, main unit has built-in)
Vol. De càrregatage 5V / USB
Mida de l'article 222 * 80 * 46 mm / 8.74 * 3.15 * 1.81 polzades
Pes de l'article 311 g / 10.98 oz
Origen Xina continental
Certificació CE
TC-8100 Specifics
Particle Size Channels 3-channel: 0.3μm, 2.5μm, 10μm
Interval PM2.5 0~1000μg/m³
PM2.5 Precisió ±12 μg/m³
TC-8200 Specifics
Particle Size Channels 6-channel: 0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10μm
Interval PM2.5 0~1000μg/m³
PM2.5 Precisió ±10μg/m³ (0~100μg/m³), ±10% (100~1000μg/m³)
Number of Particles Output Range ≤2,000,000 Granule/L
Cleanliness Standard Meets ISO 14644-1 ISO5 Level-ISO9 Level

7. Consells d'usuari

  • Col·locació òptima: For accurate ambient air quality readings, place the device in an open area, away from direct airflow from vents or windows, and at a height representative of human breathing zones.
  • Càrrega regular: To ensure continuous operation, regularly charge the device, especially before extended monitoring sessions.
  • Registre de dades: Utilize the data logging feature to track air quality trends over time. Export data periodically to prevent loss and for detailed analysis.
  • Personalització de l'alarma: Set the PM2.5 alarm threshold according to your specific needs or local air quality guidelines to be alerted to elevated particle levels.
  • Brillantor de la pantalla: Adjust screen brightness to conserve battery life, especially in well-lit environments.

8. Garantia i assistència

Per obtenir informació sobre la garantia, assistència tècnica o consultes de servei, poseu-vos en contacte amb el fabricant o amb el punt de venda. Conserveu el rebut de compra com a comprovant de compra.