1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of your Gaqqee Thermistor Waterproof Temperature Sensor Probe. These probes are designed for accurate and reliable temperature measurement in various environments, including wet or humid conditions, making them suitable for a wide range of household and industrial applications. Please read this manual thoroughly before using the product to ensure safe and optimal performance.
Figure 1: Gaqqee Thermistor Waterproof Temperature Sensor Probes
2. Informació de seguretat
Si us plau, observeu les següents precaucions de seguretat per evitar lesions o danys al producte:
- Assegureu-vos que la font d'alimentació voltage is within the specified range (3.0V~5.5V) to avoid damage to the sensor or connected equipment.
- Do not expose the sensor to temperatures outside its operating range (-55°C to +125°C) as this may lead to inaccurate readings or permanent damage.
- While the probe is waterproof and moisture-proof, ensure all electrical connections are properly insulated and protected from moisture, especially when used in wet environments.
- Do not attempt to modify or disassemble the sensor probe. Unauthorized modifications can lead to malfunction and void any warranty.
- Mantenir el producte fora de l'abast dels nens.
3. Producte acabatview
The Gaqqee Thermistor Waterproof Temperature Sensor Probe utilizes advanced NTC thermistor or DS18B20 digital sensor technology for sensitive and reliable temperature measurement. Each probe features a durable stainless steel housing, making it waterproof, moisture-proof, and anti-rust, suitable for various demanding applications.
Característiques principals:
- Tecnologia avançada: Employs sensitive and reliable NTC thermistor or DS18B20 digital sensor.
- Construcció duradora: Stainless steel probe housing for waterproof, moisture-proof, and anti-rust performance.
- Ampli rang de mesura: Capable of measuring temperatures from -55°C to +125°C.
- Flexible Lead Lengths: Available in various lead lengths (0.5m, 1m, 2m, 2.5m, 3m) for remote temperature sensing.
- Aplicació àmplia: Ideal for household air conditioners, refrigerators, water fountains, drying boxes, constant temperature boxes, and other temperature control systems.
Figure 2: Close-up of the Waterproof Probe Tip
4. Especificacions
| Paràmetre | Valor |
|---|---|
| Teoria | Sensor de temperatura (termistor) |
| Tipus de visualització | DIGITAL (when connected to a compatible controller) |
| Certificació | CE |
| Estil | Estació de peu |
| Ús | llar |
| És un dispositiu intel·ligent | No |
| Bateria inclosa | No |
| Alimentació Voltage | 3.0V ~ 5.5V |
| Temperatura de treball | -55 °C ~ +125 °C |
| Material de la sonda | Acer inoxidable |
| Material del cable | PVC Wire |
| Pes | Approx. 20g (varies by length) |
| Lead Lengths Available | 0.5m, 1m, 2m, 2.5m, 3m |
5. Configuració i instal·lació
The sensor probes are designed for easy integration with compatible temperature controllers such as W1209, STC-1000, and W3001. The specific wiring will depend on the sensor type (NTC 10K or DS18B20) and the controller's input requirements.
5.1. NTC 10K Thermistor Probe Wiring
NTC 10K thermistors typically have two wires and are connected to analog input pins on a controller. The controller measures the resistance change of the thermistor, which corresponds to temperature. Ensure your controller supports NTC 10K sensors.
Figure 3: NTC 10K Thermistor Probe (with JST connector)
Passos de connexió:
- Identify the temperature sensor input terminals on your controller (e.g., STC-1000).
- Connect the two wires from the NTC 10K probe to these terminals. Polarity usually does not matter for NTC thermistors, but consult your controller's manual for specific instructions.
- Secure the connections to prevent accidental disconnection.
5.2. DS18B20 Digital Temperature Probe Wiring
DS18B20 sensors are digital and use a 1-Wire protocol, typically requiring three connections: VCC (power), GND (ground), and DQ (data). Some versions may have only two wires if parasitic power mode is used, but most common implementations use three. Ensure your controller supports DS18B20 digital sensors and the 1-Wire protocol.
Figure 4: DS18B20 Digital Temperature Probes (with exposed wires)
Typical 3-Wire Connection (consult your controller's manual for exact pinout):
- Fil vermell: VCC (Power, e.g., +5V)
- Fil negre: GND (terra)
- Fil groc: DQ (Data Line, often requires a pull-up resistor to VCC, typically 4.7kΩ)
Passos de connexió:
- Identify the VCC, GND, and Data input terminals on your controller.
- Connect the corresponding wires from the DS18B20 probe to these terminals.
- If required by your controller or circuit design, install a pull-up resistor between the Data line and VCC.
- Assegureu totes les connexions.
5.3. Col·locació de la sonda
Place the stainless steel probe tip in the environment where temperature measurement is required. Ensure the probe is fully immersed if measuring liquid temperatures, or adequately exposed to air if measuring ambient temperatures. The waterproof design allows for direct contact with water or other non-corrosive liquids.
6. Instruccions de funcionament
Once the sensor probe is correctly installed and connected to a compatible temperature controller, its operation is straightforward:
- Encès: Apply power to your temperature controller.
- Visualització de la temperatura: The controller should automatically detect the sensor and display the current temperature reading.
- Configuració del controlador: Refer to your specific temperature controller's manual (e.g., W1209, STC-1000, W3001) for instructions on setting temperature thresholds, calibration, and other operational parameters. The sensor probe acts as the input device, providing accurate temperature data to the controller.
7. Manteniment
These temperature sensor probes are designed for low maintenance. Follow these guidelines to ensure longevity:
- Neteja: If the stainless steel probe tip becomes dirty, gently wipe it with a soft, damp cloth. Avoid using abrasive cleaners or solvents that could damage the probe or cable.
- Inspecció: Periodically inspect the cable for any signs of damage, such as cuts, kinks, or exposed wires. Ensure the probe tip is free from excessive buildup that might affect readings.
- Emmagatzematge: When not in use, store the sensor in a clean, dry place within its specified temperature range.
8. Solució De Problemes
If you encounter issues with your temperature sensor probe, consider the following common problems and solutions:
- No Temperature Reading / Error Display:
- Check all wiring connections to ensure they are secure and correctly matched (VCC, GND, Data for DS18B20; two terminals for NTC).
- Verify that the power supply to the controller is stable and within the sensor's operating voltage gamma.
- Ensure the correct sensor type (NTC 10K or DS18B20) is selected or compatible with your temperature controller.
- For DS18B20, confirm the presence and correct value of the pull-up resistor on the data line if required by your setup.
- Inspeccioneu el cable per veure si hi ha danys visibles.
- Lectures de temperatura inexactes:
- Ensure the probe tip is properly positioned in the area where temperature needs to be measured and is not affected by external heat sources or drafts.
- Check for any buildup or debris on the probe tip that might insulate it from the environment.
- If your controller has a calibration function, perform a calibration according to its manual.
- Verify that the sensor type configured in your controller matches the connected probe (e.g., NTC 10K vs. DS18B20).
9. Consells d'usuari
- Compatibilitat del controlador: When selecting a sensor, always confirm its compatibility with your temperature controller. For example, the STC-1000 controller typically uses NTC 10K thermistors. If you are using a DS18B20 sensor, ensure your controller explicitly supports the 1-Wire digital protocol.
- Longitud del cable: While these probes are available in lengths up to 3 meters, for applications requiring significantly longer distances (e.g., 30 meters), consider potential signal degradation. For DS18B20 sensors, longer cable runs might require careful wiring, shielded cables, or signal amplifiers to maintain data integrity.
- Segellat ambiental: Even though the probe is waterproof, ensure that the connection points to your controller are adequately protected from moisture, especially in high-humidity or outdoor installations, to prevent short circuits or corrosion.
10. Preguntes freqüents (FAQ)
- Q: Which sensor type is suitable for an STC-1000 temperature controller?
- A: The STC-1000 controller is commonly designed to work with NTC 10K thermistor probes. Please verify your specific STC-1000 model's manual for confirmation.
- Q: Can I use a sensor with a 30-meter cable length?
- A: Our standard probes are available up to 3 meters. While it might be technically possible to extend cables, signal integrity can be an issue, especially for digital sensors like DS18B20. For custom lengths or very long runs, specialized wiring and signal conditioning may be required. It is recommended to use the provided lengths or consult an expert for extensions.
- Q: Is the entire cable waterproof?
- A: The stainless steel probe tip is waterproof and moisture-proof. The PVC wire itself is resistant to moisture, but the connection points (exposed wires or connectors) should be properly sealed and protected if they are to be exposed to wet conditions.
11. Garantia i Suport
For detailed warranty information and customer support, please refer to the official product documentation or contact your retailer. A comprehensive user manual in PDF format is available for download, which may contain additional technical details and support information.
PDF de referència: Manual d'usuari (PDF)