1. Introducció
The EARU PC321-TY Power Clamp is designed to monitor electricity usage in your facility by connecting current transformer clamps to the power cables. It can measure Voltage, Current, Active Power, Power Factor, and total energy consumption in real-time. This device is compatible with both single-phase and three-phase electricity systems.
Aquesta guia ofereix un sobreview of the product and assists with the initial setup and installation.
Característiques principals:
- Tuya compliant, supporting Tap-to-Run and automation with other Tuya devices.
- Compatible with Single/3-phase electricity.
- Mesura en temps real Voltage, Current, Active Power, and total energy consumption.
- Apte tant per a aplicacions residencials com comercials.
- Lleuger i fàcil d'instal·lar.
- L'antena externa evita que el senyal sigui blindat.
Note: The bidirectional measurement function only supports the WiFi version and does not support the ZigBee version.
2. Manipulació de seguretat
WARNING: Failure to follow these safety notices could result in fire, electric shock, other injuries, or damage to the Power Clamp i altres propietats. Llegiu tots els avisos de seguretat següents abans d'utilitzar el Power Clamp.
- El poder clamp must be installed and serviced only by qualified electrical personnel.
- No toqueu els terminals del dispositiu durant la prova.
- Turn off all power supply for this equipment before installing.
- Assegureu-vos que la font d'alimentació estigui apagada abans de connectar-la o desconnectar-la a un dispositiu auxiliar.
- Utilitzeu sempre un volum correctament classificattage dispositiu de detecció per confirmar que l'alimentació està apagada.
- Replace all devices, doors, and covers before applying power to the equipment.
- Eviteu la humitat elevada o les temperatures extremes.
- Eviteu l'exposició prolongada a la llum solar directa o a la llum ultraviolada intensa.
- No deixeu caure ni exposeu la unitat a vibracions intenses.
- No desmunteu ni intenteu reparar la unitat pel vostre compte.
- No exposeu la unitat ni els seus accessoris a líquids inflamables, gasos o altres explosius.
3. Producte acabatview
Familiarize yourself with the components of your energy meter:


Components:
- Unitat principal: The central processing unit for energy measurement.
- CT (Current Transformer) Clamps: Used to measure current flow in power cables. The device supports 3 CT clamps.
- Antena externa: For wireless communication (WiFi or ZigBee).
- Cable d'entrada de CA: Per alimentar el dispositiu.
- Indicador LED: Provides status feedback (Red LED flashing: Device not joined to ZigBee network; Green LED solid on: Device joined to ZigBee network).
- Botó de restabliment: Located on the back of the main unit. Press and hold for 5 seconds to restore factory settings (energy data will not be cleared). Press twice consecutively within 10 seconds to clear energy data.
4. Especificacions tècniques
| Característica | Especificació |
|---|---|
| Número de model | PC321-TY |
| Nom de marca | EARU |
| Font d'alimentació | AC |
| Vol. De sortidatage | 100-240V CA 50/60 Hz |
| Corrent nominal | 80A-1000A (Optional) |
| Corrent màxim de funcionament | 150A & Above |
| Classe de precisió | 1% |
| Fase | Trifàsica |
| Temperatura de funcionament | -20 ℃ - +55 ℃ |
| Humitat de funcionament | ≤ 90% sense condensació |
| Dimensions | 86 * 86 * 37 mm |
| Freqüència sense fil | WiFi 2.4GHz IEEE 802.15.4 |
| Protocol | ZigBee 3.0 |
| Cicle d'informes | 5 segons |
| Certificació | CE, RoHS |
| Bateria inclosa | No |
CT Clamp Especificacions:

| Model | 80A | 120A | 200A | 300A | 500A | 750A | 1000A |
|---|---|---|---|---|---|---|---|
| Φ (Inner Diameter) | 10 mm | 16 mm | 24 mm | 24 mm | 36 mm | 50 mm | 50 mm |
| A | 34 mm | 37 mm | 53 mm | 53 mm | 68 mm | 93 mm | 93 mm |
| B | 24 mm | 30 mm | 45 mm | 45 mm | 59 mm | 82 mm | 82 mm |
| C | 42 mm | 51 mm | 65 mm | 65 mm | 90 mm | 122 mm | 122 mm |
| E | 32 mm | 43 mm | 44 mm | 44 mm | 53 mm | 70 mm | 70 mm |
| G | 26 mm | 34 mm | 34 mm | 34 mm | 42 mm | 60 mm | 60 mm |
5. Instal·lació i cablejat
Important: Please make sure the main power in your facility is OFF before installing. Failure to follow these instructions will result in death or serious injury.
5.1. Muntatge del dispositiu
La potència Clamp unit has a mounting bracket for installation:
- Use the mounting bracket as a template to mark two holes on the wall for screws.
- Secure the mounting bracket onto the wall using screws. Install wall plugs if necessary.
- Align the hooks of the mounting bracket with the mounting holes on the Power Clamp unit. Fit the hooks into the mounting holes to secure the device.

5.2. Instruccions de cablejat
Seguiu els esquemes següents com a exempleample per cablejar la potència Clamp for different phases.
5.2.1. Connecting AC Input Cable
- Connect the AC Input cable to a socket near the Electrical Box to power on the Power Clamp segons el diagrama de cablejat de fase corresponent.
- Attach both ends of the Current Transformer Cables. Spin the waterproof latch clockwise until both ends are tightened and secured.

5.2.2. Connecting CT Clamps
Obriu el clamp and apply it to the electric meter cable. The arrow on the clamp should face the correct direction of the electricity current flow (P1→P2). If the arrow faces the reverse direction, the reading meter will display 0.

Nota important:
- The phase of the circuit measured by the CT needs to be consistent with the power supply phase of that CT. For example, if the CT of L1 measures the L1 circuit, the power supply for L1 must also be connected to the L1 phase. You cannot clamp the CT of L1 on the L2 phase if the power supply of L1 is still connected to the L1 phase.
- Assegureu-vos que el clamp of L1/L2/L3 corresponds to L1/L2/L3 of the circuit to be tested.
- La fletxa de la clamp should face the correct direction of the electricity current flows.
5.2.3. Esquemes de cablejat
3 Phase electricity wiring diagram:

Video Tutorial for Wiring:
Video 1: Step-by-step guide on wiring the energy meter in a three-phase electrical box. It demonstrates connecting neutral and phase wires, and correctly installing CT clamps with attention to current direction.
6. Configuració de xarxa
The device can be configured via the Smart Life App. Ensure your wireless router operates on 2.4GHz.
6.1. Baixeu l'aplicació Smart Life
Download the "Smart Life" application from your App Store or Google Play Market. You can also scan the QR code below to download and install.

6.2. Pairing Method 1 (Scan)
- Open the Smart Life app and click the 'Scan' button in the upper right corner of the App Home page.
- Scan the QR code provided in the manual (or on the device/packaging) to configure the network.
6.3. Pairing Method 2 (ZigBee Gateway)
Note: This method is for the ZigBee version and requires a dedicated ZigBee gateway.
- Make sure your Tuya ZigBee gateway is successfully connected to your Smart Life App.
- Assegureu-vos la potència clamp està dins del rang de senyal del vostre Tuya ZigBee Gateway.
- Enceneu el clamp. If the LED indicator is not flashing red, reset the device (press and hold the reset button for 5 seconds).
- Enter your ZigBee gateway settings in the Smart Life App and set it to permit joining to add a subdevice.
- After a few seconds, the power clamp will automatically join the gateway. Once successfully added, you will see the new power clamp in the Smart Life App.
7. Instruccions de funcionament
Once installed and configured, the EARU PC321-TY energy meter allows you to monitor various electrical parameters through the Smart Life App.
7.1. Monitorització en temps real
Monitor Current, Active Power, Voltage, and Power Factor in real-time. Daily, weekly, and monthly consumption and production data can be viewed with charts in the Tuya App. This allows you to see how much electricity you are consuming, when, and how much excess energy you are producing back to the grid.

7.2. Bidirectional Measurement (WiFi Version Only)
The WiFi version supports bidirectional measurement, allowing you to track both energy consumption ("From Grid" energy) and energy production ("To Grid" energy), which is particularly useful for solar panel installations.

- Clip Clamp1 onto Grid: Measures "From Grid" or "To Grid" energy. If the measured current direction is P1→P2, energy is accumulated as "From Grid" energy. If P2→P1, energy is accumulated as "To Grid" energy.
- Clip Clamp2 onto Inverter: Measures how much energy is generated by the inverter. The clamp direction needs to point to the Inverter.
- Clip Clamp3 onto Load: Measures how much energy is consumed by the load. The clamp direction needs to point to the Load.
7.3. Control per veu
The device supports voice control through intelligent speakers like Amazon Alexa and Google Assistant, allowing for hands-free operation.

8. Manteniment
- Mantingueu el dispositiu net i lliure de pols.
- Eviteu exposar el dispositiu a la llum solar directa, a una humitat elevada o a temperatures extremes.
- Regularly check wiring connections for tightness and integrity.
- If the device malfunctions, do not attempt to repair it yourself. Contact qualified personnel.
Restablir el dispositiu:
To restore the power clamp to default factory settings (energy data will not be cleared), press and hold the reset button for 5 seconds until the Red LED indicator flashes 3 times quickly. The device will then enter EZ mode for 3 minutes.

To clear energy data, reset the Power Clamps twice consecutively. The interval between two resets must be less than 10 seconds. After successful operation, the indicator light will flash alternately red and green 3 times.
9. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El dispositiu no s'encén | No power to AC input cable or faulty connection. | Check AC input cable connection and power source. Ensure main power is on after installation. |
| LED indicator not flashing red during pairing | Device not in pairing mode or already paired. | Press and hold the reset button for 5 seconds to enter pairing mode. |
| Inaccurate readings or 0 display | Incorrect CT clamp direction or phase mismatch. | Ensure the arrow on the CT clamp points towards the load. Verify that the CT clamp for each phase (L1, L2, L3) is connected to its corresponding phase wire. |
| No data in Smart Life App | Device not connected to network or out of range. | Check WiFi (2.4GHz) or ZigBee gateway connection. Ensure device is within signal range. Re-pair if necessary. |
| ZigBee version not showing bidirectional measurement | ZigBee protocol limitation. | Bidirectional measurement is only supported by the WiFi version. This is expected behavior for ZigBee models. |
10. Consells d'usuari
- Requisit del cable neutre: The meter requires a neutral wire for accurate voltage, current, and power measurements. Ensure your measured circuit includes a neutral wire.
- CT Clamp Direcció: Always double-check the direction of the arrow on the CT clamps. It must point towards the load for correct consumption readings. For solar generation, the arrow should point away from the load (towards the grid/inverter).
- Phase Correspondence: When using multiple CT clamps in a three-phase system, ensure that each clamp (L1, L2, L3) is correctly installed on its corresponding phase wire. Mismatched phases will lead to incorrect data.
- App Data Visualization: The Smart Life app provides bar graphs for kWh consumption per phase. While current measurements are available, trend lines for current might not be directly supported in the same graphical format as energy consumption.
- Alerts and Routines: The device can often be integrated with smart home platforms like Alexa for routines. Check the Smart Life app for options to set up alerts based on consumption or lack thereof, and to create routines with other smart devices.
- Intensitat del senyal: For ZigBee versions, ensure the device is close enough to the ZigBee gateway for a stable connection. For WiFi, a strong 2.4GHz signal is crucial.
11. Garantia i Suport
For warranty information and technical support, please refer to the official product page or contact the seller directly. This manual provides general operational guidelines and does not cover specific warranty terms or advanced support procedures.
Podeu descarregar un manual d'usuari en format PDF: Manual d'usuari (PDF).