1. Introducció
The SINOTIMER MT-S is a versatile digital PID temperature controller designed for precise temperature management in both heating and cooling applications. It features a dual-line, three-digit display for process value (PV) and set value (SV), and supports multiple thermocouple input types. This manual provides essential information for the safe and effective operation of your MT-S temperature controller.
2. Informació de seguretat
- Desconnecteu sempre l'alimentació abans de la instal·lació o el manteniment.
- Ensure proper wiring according to the provided diagrams to prevent damage or electric shock.
- This device should be installed by qualified personnel.
- Do not operate the device in environments exceeding the specified ambient temperature and humidity ranges, or where corrosive gases are present.
- Comproveu que la font d'alimentació voltage matches the device's requirements (AC100-240V 50/60Hz).
3. Contingut del paquet
- 1 x SINOTIMER Digital PID Temperature Controller (MT-S)
- 1 x manual d'usuari en anglès
4. Producte acabatview
The SINOTIMER MT-S features a compact design with a clear digital display and intuitive control buttons. It is designed for panel mounting.
4.1 Disposició del panell frontal

The front panel includes a dual digital display and several control buttons:
- VA (Valor del Procés): Displays the measured temperature or various parameter symbols.
- SV (Valor definit): Displays the target temperature or various parameter set values.
- OUT (Output Indicator): Illuminates when the control output is active.
- AT (Auto-Tune Indicator): Illuminates when PID auto-tuning is in progress.
- AL1 (Alarm Indicator): Illuminates when an alarm condition is met.
- ▲ (Up Arrow): Increases numerical values.
- ▼ (Down Arrow): Decreases numerical values.
- ◀ (Shift Key): Moves the cursor or shifts digits during parameter setting.
- Mode: Used for calling up parameters and registering set values.
4.2 Available Models and Dimensions

The MT-S model has the following dimensions:
- Mida del panell: 48 x 48 mm
- Mida del forat d'instal·lació: 45 x 45 mm
5. Especificacions
| Característica | Especificació |
|---|---|
| Font d'alimentació | AC100-240V 50 / 60Hz |
| Interval de configuració de temperatura | -50 ~ +999 ℃ / °F |
| Input Thermocouple Types | K, J, E, N (user selectable) |
| Aplicació de control | Calefacció o refrigeració |
| Mostra | Two lines, Three digits (Celsius ℃ / Fahrenheit °F selectable) |
| Resolució de visualització | 1 °C / 1 °F |
| Control de precisió | ± 0.5%FS |
| Mode de control | PID, ON/OFF (ON/OFF control when P=0) |
| Sortida de control | One group control output, supporting 2 methods:
|
| Alarma | One alarm, 6 kinds of alarm modes: high deviation / low deviation / process value alarm |
| Consum d'energia | ≤ 10VA |
| Temperatura ambient | 0-50°C |
| Humitat ambiental | 30-85% RH (non-condensing, no corrosive gas) |
| Material | Plàstic |
6. Configuració i instal·lació
6.1 Muntatge en panell
The MT-S controller is designed for panel mounting. Ensure the installation hole size is 45 x 45 mm for a secure fit.
6.2 Diagrama de cablejat i connexions
The controller supports two main output methods and accepts various thermocouple inputs. Refer to the diagram below for proper wiring.

Mètodes de sortida:
- Sortida de relé:
- Directly connected to the heat pipe.
- Connected to an AC contactor.
- Specifications: RELAY relay output 5A/220V (for contactor or heat pipe).
- Solid State Output (SSR):
- Connected to a Solid State Relay (SSR).
- Specifications: SSR solid state output connected to DC12V (for DC controlled AC solid state relay).
Input Methods:
- The controller accepts thermocouple inputs with index numbers K, J, E, and N. Ensure the correct thermocouple type is selected in the controller's settings to match your sensor.
Important: Always ensure power is disconnected before making any wiring connections. Incorrect wiring can damage the device or cause safety hazards.
7. Instruccions de funcionament
7.1 Encès
Once properly wired and installed, apply power to the controller. The display will show the current Process Value (PV) and Set Value (SV).
7.2 Setting the Temperature (SV)
- Premeu el botó MODE button briefly to enter the set value adjustment mode. The SV display will flash.
- Utilitza el ▲ i ▼ botons per ajustar la temperatura desitjada.
- Utilitza el ◀ (Shift) button to move between digits for faster adjustment.
- Premeu el botó MODE button again to confirm the new set value and exit the adjustment mode.
7.3 Configuració dels paràmetres
The controller has various parameters for advanced configuration, including control mode (PID/ON-OFF), alarm settings, and thermocouple type. Accessing and adjusting these parameters typically involves pressing and holding the MODE button for several seconds to enter the parameter menu. Refer to the detailed parameter list in the full manual for specific instructions on each setting.
- Mode de control: Select between PID control for precise regulation or ON/OFF control (when P=0) for simple switching.
- Configuració d'alarma: Configure the single alarm with 6 modes (high deviation, low deviation, process value alarm).
- Tipus de termoparell: Ensure this matches your connected sensor (K, J, E, N).
- Unitat de temperatura: Switch between Celsius (℃) and Fahrenheit (°F) as needed.
7.4 PID Auto-Tuning (AT)
For optimal performance with PID control, auto-tuning is recommended. This process automatically calculates the best PID parameters for your specific system. Consult the full manual for detailed steps on initiating and completing the auto-tuning process. The AT indicador lamp will illuminate during auto-tuning.
8. Manteniment
- Neteja: Wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspecció: Periodically check wiring connections for looseness or damage.
- Medi ambient: Ensure the operating environment remains within specified temperature and humidity limits and free from corrosive gases.
Caution: Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
9. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El controlador no s'encén. | Sense subministrament elèctric; cablejat incorrecte. | Comproveu les connexions d'alimentació i assegureu-vos que el volum sigui correctetage (AC100-240V). Verify wiring against the diagram. |
| Incorrect temperature reading (PV). | Thermocouple not connected; incorrect thermocouple type selected; damaged thermocouple. | Ensure thermocouple is securely connected. Verify the selected thermocouple type in settings matches the sensor. Replace damaged thermocouple. |
| Output (OUT) not activating. | Set value (SV) not reached; control mode incorrect; wiring issue. | Check SV and PV values. Ensure control mode (heating/cooling) is appropriate. Verify output wiring. |
| Temperature fluctuates widely in PID mode. | PID parameters not optimized. | Perform PID auto-tuning to optimize control parameters for your system. |
10. Consells d'usuari
- For detailed parameter settings and advanced functions, always refer to the comprehensive English manual included with your product. This will provide specific steps for configuring each parameter.
- When switching between Celsius and Fahrenheit, ensure all relevant set points and alarm limits are re-checked and adjusted if necessary.
11. Garantia i Suport
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.