1. Introducció
The SINOTIMER TM919B is a robust 30A programmable digital timer switch designed for automatic control of various electrical equipment. This DIN rail-mounted device offers 7-day, 24-hour programming capabilities, allowing users to set up to 16 distinct ON/OFF programs daily or weekly. It is an ideal solution for managing the operation of street lamps, neon lights, signs, general lighting, water heaters, air conditioners, billboards, rice cookers, superchargers, sprayers, bottling machines, preheaters, agricultural facilities, and broadcasting equipment. The timer switch incorporates a 1.2V/40mA rechargeable battery to retain programmed settings during power outages, ensuring reliable operation. Key features include low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and a user-friendly setup process.
2. Informació de seguretat
- Always disconnect power at the main circuit breaker before attempting any installation, wiring, or maintenance.
- Installation should be performed by a qualified electrician or an individual with a thorough understanding of electrical systems.
- Ensure all wiring adheres to local and national electrical codes and regulations.
- Do not exceed the maximum load rating of 30A for the timer switch. Overloading can cause damage to the device and create a fire hazard.
- Manteniu el dispositiu allunyat de l'aigua, la humitat i les temperatures extremes.
- No intenteu obrir ni reparar el dispositiu vosaltres mateixos. Encarregueu totes les tasques de manteniment a personal qualificat.
3. Contingut del paquet
- 1 x SINOTIMER TM919B Digital Timer Switch
- 1 x Manual d'usuari
4. Producte acabatview i Controls
Familiarize yourself with the components and controls of your TM919B timer switch:

Botons de control:
- P (Programa): Enters program setting mode. Press repeatedly to cycle through ON/OFF settings.
- D+ (Day): Adjusts the day of the week or program day.
- H+ (Hour): Adjusts the hour for current time or program time.
- M+ (Minute): Adjusts the minute for current time or program time.
- RESET: Esborra tots els paràmetres i restableix el temporitzador als valors predeterminats de fàbrica.
- MANUAL: Alterna entre els modes ON, AUTO i OFF.
Indicadors de visualització:
- Th: Indicates Thursday (example, will show current day).
- AM PM: Time format indicator.
- ON/AUTO/OFF: Current operating mode.
- ON (Red LED): Indicates the timer output is currently ON.
5. Especificacions
| Característica | Especificació |
|---|---|
| Model | TM919B |
| Font d'alimentació | AC220V, 50 / 60Hz |
| Capacitat de càrrega | 30A (càrrega resistiva) |
| Canvia de contacte | 1 Change-over Switch |
| Esdeveniments programables | 16 ON/OFF programs per day or week |
| Interval mínim | 1 minut |
| Interval de cronometratge | 1 minute to 168 hours (7 days) |
| Bateria interna | 1.2V/40mA rechargeable (for program retention) |
| Precisió | ≤1s/24h at 25°C |
| Material | ABS + Components electrònics |
| Color | Blanc |
Dimensions:

- Davant View: 3.5cm (width) x 8.7cm (height)
- lateral View: 6.5cm (depth) x 4.7cm (top width) x 4.5cm (main body height) x 3cm (DIN rail clip height)
6. Instal·lació
The TM919B timer switch is designed for DIN rail mounting. Ensure the DIN rail is securely installed in a suitable enclosure.
Diagrama de cablejat:
Refer to the diagram below for proper wiring. Always ensure power is disconnected before making any electrical connections.

- Entrada d'alimentació: Connect the Live (L) wire to terminal 1 and the Neutral (N) wire to terminal 2. The timer requires AC220V power.
- Connexions de sortida: The timer has a single change-over switch output.
- Terminal 4: Common (COM) output.
- Terminal 3: Normally Open (NO) contact. This contact closes when the timer is ON.
- Terminal 5: Normally Closed (NC) contact. This contact opens when the timer is ON.
- Connexió de càrrega: For loads up to 30A, you can directly connect your appliance to the appropriate output terminals (e.g., L to terminal 4, appliance to terminal 3, and appliance to N). For higher inductive loads or loads exceeding 30A, it is highly recommended to use an external contactor (as shown in Figure 3) to protect the timer's internal relay.
7. Configuració i programació
7.1 Initial Setup / Reset
- Upon first power-up or after a long period of no power, the display may be blank. The internal battery will charge once power is applied.
- Premeu el botó RESET button (usually a small recessed button, use a pointed object like a pen tip) to clear all previous settings and reset the timer. The display will show "0:00" and "AUTO".
7.2 Configuració de l'hora actual
- Premeu el botó D+ botó per configurar el dia actual de la setmana.
- Premeu el botó H+ botó per configurar l'hora actual.
- Premeu el botó M+ botó per configurar el minut actual.
- The time will automatically save after a few seconds of inactivity.
7.3 Programació de cicles d'encesa/apagada
The TM919B allows for up to 16 ON and 16 OFF programs. Each program consists of a specific time and day(s) for the timer to switch ON or OFF.
- Premeu el botó P button once. The display will show "1 ON" (for the first ON program).
- Premeu D+ to select the day(s) for this program. Options include: every day, specific weekdays, weekends, etc.
- Premeu H+ to set the hour for the "1 ON" program.
- Premeu M+ to set the minute for the "1 ON" program.
- Premeu P again. The display will show "1 OFF" (for the first OFF program).
- Repeat steps 2-4 to set the day(s), hour, and minute for the "1 OFF" program.
- Continueu prement P to cycle through "2 ON", "2 OFF", up to "16 ON", "16 OFF", setting each as needed.
- If you don't need all 16 programs, simply stop pressing P after setting your desired programs. The timer will exit programming mode after about 10 seconds of inactivity.
- Per sortir del mode de programació en qualsevol moment, premeu la tecla MANUAL botó.
8. Instruccions de funcionament
Once programmed, the timer will operate automatically according to your settings. The current operating mode is displayed on the LCD screen (ON, AUTO, or OFF).
Anulació manual:
El MANUAL button allows you to temporarily override the programmed schedule without deleting it. Pressing the MANUAL button cycles through the following modes:
- ACTIVITAT: The output is forced ON, regardless of the program.
- AUTOMÀTIC: El temporitzador funciona segons l'horari programat.
- DESACTIVAT: The output is forced OFF, regardless of the program.
To return to automatic operation, press the MANUAL fins que aparegui "AUTO".
9. Manteniment
- Keep the timer switch clean and dry. Use a soft, dry cloth to wipe the exterior.
- No utilitzeu netejadors abrasius ni dissolvents.
- Assegureu-vos una ventilació adequada al voltant del dispositiu per evitar el sobreescalfament.
- The internal rechargeable battery is designed for long-term use and typically does not require replacement during the product's lifespan.
- There are no user-serviceable parts inside the unit. Any unauthorized opening or modification will void the warranty.
10. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla està en blanc o tènue. | No power supply or internal battery discharged. | Check power connections. If power is present, allow time for the internal battery to charge (up to 4 hours). |
| Timer is not switching ON/OFF as programmed. | Incorrect program settings, manual override engaged, or incorrect current time. | Verify all ON/OFF programs are set correctly. Ensure the timer is in "AUTO" mode (press MANUAL button until "AUTO" is displayed). Check that the current day and time are set accurately. |
| Output is always ON or always OFF. | Accionament manual activat. | Premeu el botó MANUAL button until "AUTO" is displayed on the screen. |
| Appliance connected to timer is not working. | Appliance fault, incorrect wiring, or timer output not active. | Test the appliance directly. Verify wiring connections (refer to Section 6). Check timer mode and program. Ensure the load does not exceed 30A. |
11. Consells d'usuari
- For Inductive Loads: If connecting motors, fans, or other inductive loads, consider using an external contactor. This will protect the timer's internal relay from high inrush currents and extend its lifespan.
- Verifiqueu el cablejat: Always double-check your wiring connections against the provided diagram before applying power to prevent damage to the timer or connected appliances.
- Test Programs: After programming, use the MANUAL button to cycle the output ON and OFF to quickly verify your wiring and ensure the connected appliance responds as expected, without waiting for the scheduled time.
- Potència Outage Protecció: The built-in rechargeable battery ensures your programs are retained during power outages. However, for extended outages, the battery may discharge, requiring you to reset the time.
12. Garantia i Suport
For technical assistance, warranty claims, or product support, please contact your original retailer or the manufacturer directly. Please have your product model number (TM919B) and proof of purchase readily available when seeking support.